• 제목/요약/키워드: Fire spread rate

검색결과 101건 처리시간 0.026초

LSC를 이용한 생활용품의 발열량 특성에 관한 연구 (A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter))

  • 박영주;백창선;이해평;홍이표
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

산불 공중진화 방화선 구축형태 및 진화방법에 관한 연구 (Study of Aerial Fire Line Construction and Suppression Method on Forest Fire)

  • 배택훈;이시영
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.26-31
    • /
    • 2010
  • 본 연구는 우리나라의 각종 소.중형 및 대형 산불의 공중진화 경험을 바탕으로 산불행태와 헬기의 현장운영을 고려한 산불 공중진화 방화선 구축형태 및 진화방법에 대하여 제안하였다. 산불확산은 현장의 지세, 경사, 바람, 수종 등에 영향을 받으므로 공중진화 방화선을 구축할 때에는 연소방향 및 형태, 강도 등을 분석한 후 진화작업을 실시하여야 하며, 특히 연기로 인하여 시계가 방해 받으므로 안전을 고려해 진화작업을 하는 것이 중요하다. 따라서 본 연구에서는 산불현장 공중진화 경험을 바탕으로 A형에서 M형까지 13개의 산불 공중진화 방화선 구축형태 및 진화방법을 제안하였다.

ISO 9708 룸 설비를 이용한 구형 지하철 내장재 화재시험 (Fire Test of Old Type Interiors of Subway Vehicle in ISO 9705 Room)

  • 이덕희;박원희;정우성;황정호
    • 한국철도학회논문집
    • /
    • 제13권5호
    • /
    • pp.481-487
    • /
    • 2010
  • 구형 지하철 전동차의 내장재에 대하여 ISO 9705 시험 설비를 이용하여 화재시험을 수행하였다. 시험에 사용된 점화용 버너는 CEN/TS 45545-1 규정에 따라 출력을 조정하였다. 이 내장재 화재시험의 목적은 화원의 규모에 따라서 철도차량에서의 화재거동과 화염의 전파 경로를 평가함과 동시에 객실 내장재의 화재가 플래시오버로 진행하는 경로의 화재 데이터를 제공하는 것이다. 시험으로부터 시간에 따른 위치 별 온도 값과 열류량 및 열방출률을 측정하였고 열방출률은 수정된 화염면적기반 합량법으로 계산한 결과와 비교하였다. 이 시험 결과는 CFD 화재 시뮬레이션 기법을 이용한 철도차량 화재해석의 검증 데이터로 활용될 수 있을 것이다.

내장용 판재 및 루버의 연소발열특성 연구 (A Study on the Burning Characteristics of Interior Boards and Louvers)

  • 남동군;김성찬
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.34-39
    • /
    • 2014
  • 건축물의 성능위주 소방설계의 활용성 및 신뢰성을 향상시키기 위해서는 다양한 화재실험 및 조사 등을 통해 가연물의 연소물성에 관한 광범위하고 다양한 데이터베이스가 필요하다. 본 연구에서는 건축물의 성능위주 소방설계에 활용하기 위해 건축물의 내장용 판재 2종과 내장용 루버 3종을 대상으로 연소시험을 실행하여 연소발열특성 등을 파악하였다. 또한 내장용 판재는 그 두께에 따라 최대열방출률 등 연소발열성상에 차이가 발생할 가능성이 있으므로 판재의 두께에 따라 연소시험을 수행하였다. 실험결과 내장재 판재 및 루버의 단위연소량당 평균발열량은 15.3MJ/kg~16.9MJ/kg이었고, 내장용 판재의 평균최대열방출률과 평균최대이산화탄소 농도는 판재의 두께에 따라 차이가 있는 것이 확인되었다.

콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구 (A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test)

  • 민세홍;선주석;김상철;최용묵;이석기
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.106-111
    • /
    • 2012
  • 본 연구에서는, 건축 외장재로 많이 사용되고 있는 외단열시스템에 대해 방염 효과를 확인하기 위하여 콘칼로리미터 실험을 적용하였다. 실험 결과, 방염제의 도포 형태나 농도에 따라 초기 착화 시점을 지연하는데 효과가 있었으나, 외벽 수직화재 발생 시 외단열시스템의 방염처리는 화재에 영향을 미치지 못할 것이라는 것을 확인하였다. 또한, 외단열시스템에 사용하는 고밀도와 저밀도 스티로폼의 밀도차에 의한 화재에 미치는 영향은 차이가 없음을 확인하였다. 실험 시 외장재의 착화는 40초 전후로 발생하였으며, 방출열량도 100초 이내에 약 90 %가 발생하는 것으로 나타나 다른 외벽재료와 비교하여 초기 화재 확산이 매우 빠름을 알 수 있었다. 외단열시스템 외장재 화재로 인한 화재 확산을 방지하기 위해서는 법적으로 외단열시스템의 적용 시 건물의 용도별로 사용을 제한하거나 화염전파를 차단할 수 있는 수직외벽 구획 등의 대책이 시급히 요구된다.

입경 변화에 따른 퇴적금속 분체층의 화염전파 (Flame Spreading Over Metal Dust Deposits With Particles Size)

  • 한우섭;최이락;한인수;이정석
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.603-608
    • /
    • 2010
  • 퇴적금속분체의 입경 변화에 따른 화염전파 거동과 발화특성을 자체 제작한 실험장치와 열중량분석 시험장치를 활용하여 조사하였다. 이를 위하여 평균입경이 다른 Mg, Ti를 포함한 Zr, Ta, Mg-Al(90:10 wt%)의 금속분진과 PMMA 시료를 사용하였다. 그 결과, 금속 퇴적층의 두께가 5 mm 이상의 경우에는 화염전파속도의 퇴적층 두께에 대한 의존성이 나타나지 않았다. 평균 입경이 작을수록 Ti는 화염전파속도가 증가하지만 Mg의 경우에는 화염전파속도가 감소하였다. 평균입경 $51{\mu}m$에 있어서 Mg퇴적분체는 Mg-Al(90:10%wt)합금 퇴적분체에 비하여 화염전파속도가 약 50%가 감소하였다. 본 연구에서 조사한 금속분체 산화물층 두께는 화염전파속도와 반비례하는 경향을 보였으며 입경 변화에 따른 영향은 나타나지 않았다. 또한 Ti와 Mg의 열중량 분석시험 결과, Mg는 $550^{\circ}C$, Ta는 $578^{\circ}C$에서 발화에 의한 연소로 판단되는 중량 증가가 관찰되었다.

A Study on Smoke Movement in Room Fires with Various Pool Fire Location

  • Jeong, Jin-Yong;Ryou, Hong-Sun
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1485-1496
    • /
    • 2002
  • In order to investigate the fire-induced smoke movement in a three-dimensional room with an open door, numerical and experimental study was performed. The center, wall, and corner fire plumes for various sized fires were studied experimentally in a rectangular pool fire using methanol as a fuel. The numerical results from a self-developed SMEP (Smoke Movement Estimating Program) field model were compared with experimental results obtained in this and from literature. Comparisons of SMEP and experimental results have shown reasonable agreement. As the fire strength became larger for the center fires, the air mass flow rate in the door, average hot layer temperature, flame angle and mean flame height were observed to increase but the doorway-neutral-planeheight and the steady-state time were observed to decrease. Also as the wall effect became larger in room fires, the hot layer temperature, mean flame height, doorway-neutral-planeheight and steady-state time were observed to increase. In the egress point of view considering the smoke filling time and the early spread of plume in the room space, the results of the center fire appeared to be more dangerous as compared with the wall and the corner fire. Thus it is necessary to consider the wall effect as an important factor in designing efficient fire protection systems.

국내·외 누설률에 관한 기준 분석을 통한 국내 연기제어 기준 개선에 관한 연구 (A Study on the Improvement of Domestic Smoke Control Standards through Analysis the Standards about Air Leakage Rate of Domestic and Abroad)

  • 김혜원;한지우;이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.61-62
    • /
    • 2018
  • On this Study, it conducts the Standards investigation about air leakage of Buildings for performance improvement of Smoke control in Fire. In domestic standards, it is incomplete the Criteria standards of air leakage. Therefore it is considered that won't limit the smoke spread due to stack effect. But in the case of the United States, it conducts the Hot smoke air-Leakage test and it consider that can prevent the Smoke Spread in Compartment.

  • PDF

필로티 건물 이격거리에 따른 화재확산 위험성 연구 (A Study on the Fire Spread Risk of Resident Buildings With Pilotis)

  • 최승복;최두찬;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.103-110
    • /
    • 2017
  • 필로티구조를 가진 저층 위주의 도시형생활주택이 날로 증가하고 있는 추세이다. 대부분의 필로티 공간은 주차장으로 활용되고 있어, 이에 따른 화재의 위험이 따른다. 특히 주차장과 같은 공간은 차량으로 인해 화재하중이 높기 때문에 화염의 분출길이가 길어진다. 또한 기둥으로만 구성된 필로티의 특성상 바람의 영향으로 화세가 거세져 화염이 주변으로 확산될 경우 같은 필로티 형태의 건물이 서로 인접해 있을 경우 때 건물로의 화염 확산 위험이 있다. 필로티 구조의 주택 대부분은 이곳을 통해 출 입이 가능한 구조이기 때문에 필로티가 막히면 입주자는 건물에 갇혀 유독가스 및 화염으로 부터 안전을 위협받게 된다. 필로티 구조 건물의 주차장이 서로 인접할 때 화염 확산 방지를 위해 일정한 간격이 필요하다. 본 연구는 필로티 주차장에서 화재가 발생하였을 경우 어느 정도 거리를 유지해야 옆 건물로의 화재 확산을 막을 수 있는지에 대하여 화재시뮬레이션을 이용하여 연구하였다. 그 결과 건물은 최소 3.0m 이상을 이격하여야 하는 것으로 확인되었다.

부유 및 퇴적의 분체 조건이 화재폭발 특성에 미치는 영향 (Effect of Powder Condition on the Fire and Explosion Characteristics of Suspended and Deposited Dusts)

  • 한우섭;서동현;최이락;임진호
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.229-236
    • /
    • 2022
  • 동일 분체특성의 분진이 평균입경, 농도, 분진조건(부유 또는 퇴적) 변화에 따른 화재폭발 위험성을 조사하였다. 이를 위해 20L분진폭발시험장치, 열중량분석장치, 연소속도시험장치(UN시험법)를 사용하였다. 4종 분진(Sugar, Mg, Al, Zr)의 입경이 서로 다른 8개 분진 시료에 대하여 부유 분진의 폭발특성과 화염전파속도(FPV), 그리고 퇴적분진의 화염확산속도(FSV)를 조사하였다. 부유 분진 조건에서 Mg 및 Al 분진은 입경이 감소하면 폭발 위험성이 증가하였지만, Sugar는 입경 변화에 따른 폭발 위험성의 영향이 거의 나타나지 않았다. 부유 분진의 화염전파속도(FPV)는 마이크로 범위에서의 입경 변화보다 마이크로에서 나노로 입경이 감소하면 크게 증가하였다. 퇴적층의 화염확산속도(FSV)는 수평면(기울기 0°)보다 경사면(기울기 30°)에서 증가하는 경향을 나타냈으며, 경사면(기울기 30°) 퇴적층 조건에서는 상방 전파가 하방 전파보다 높게 나타났다.