• Title/Summary/Keyword: Fire spread

Search Result 476, Processing Time 0.258 seconds

Biological Damage and Risk Assessment of The Wood Cultural Properties in Fire Prevention Area (화재방제구역에 따른 목조문화재 생물손상 및 생물위험도 평가)

  • Kim, Dae Woon;Chung, Yong Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.104-111
    • /
    • 2015
  • The three-year inspection of 20 tree stumps in the fire prevention area around the wooden building confirmed that termite colonies had been rapidly spread. In particular, four buildings among thirty one wooden buildings of Songgwang-sa temple were infected by the termite, indicating that the habitate of termite has been spread across the fire prevention area over the temple area. However, a non-destructive microwave diagnosis showed that internal damages have been progressed until now, suggesting a high risk to the building. These results suggest that the fire prevention area should be properly maintained to have harmful element controlled. Therefore, effective methods are required to eliminate tree stumps or wood materials used to establish fire prevention area near wooden buildings.

Analysis of Fire Direction and Pine Tree Survival using to Fire Scar formed in Tree Stem after forest Fire (산불발생 후 불자국을 이용한 소나무 생존 및 지형에 따른 산불의 방향 분석)

  • 채희문;이찬용
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.1
    • /
    • pp.30-35
    • /
    • 2003
  • The study of the scars formed on the bark of pine trees damaged by forest fire was carried out in the burned area of Samchuk and Donghae in 2000. Fire scars were formed on the bark of trees when fire passed by the tree. Fire scarring is usually found on the windward and leeward sides of the tree. Fire spread was analyzed topographically using the fire scars formed at the tree stem. Fire spread was closely related to the shape, slope and direction of the forestland. Four fire direction types are classified according to the shapes of the forestland. The height of the fire scar was higher on the leeward side than on the windward side of the trees studied. The burnt area of the total bark of the tree was over 30% in dead trees and below 12% in living trees. The regression model of the burnt stem area using the height of the fire scar, the diameter of breast height and the height of tree was Y=-2.484${\times}$Height+0.04199${\times}$D.B.H-1.686${\times}$Windward+11.172${\times}$Leeward+23.432(r=0.936, F=409.968, P>0.0001).

Comparison on the fire performance of additional insulation materials for improving the fire retardancy in engine-room of FRP vessel (FRP 선박 기관실 난연성 향상을 위한 추가 방열재의 화재성능비교)

  • Choi, Jung-Min;Um, Han-Chan;Jin, Young-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1150-1155
    • /
    • 2014
  • To prevent the flame spread in FRP vessel in fire, the engine-room of the vessel should be constructed additionally with laminated fire-retardant resin over 3 times or equivalent insulation materials to former according to the relevant standard for FRP vessel structure. It is surveyed that insulation materials called 'Gel coat' are widely used in FRP fishing vessel, however, test method and its criteria for Gel coat are not clearly establish and have not been evaluated yet, while test method and criteria for fire-retardant resin and fire-retardant polyurethane composite are described in test standard for type-approval. In this study, 3 fire-retardant resins, 4 gel coats, 1 flame-retardant paint and 1 polyurethane composite were selected based on the survey and were evaluated according to both IMO FTP Code part 5 and flame-retardant test. When comparing based on CFE values from flame-spread test, average value for 4 gel coats were lower than that of 3 fire-retardant resins. As for flame-retardant test, there were no significant differences between fire-retardant resin and gel coat, based on charred area.

A Study on the Fire Spread Risk of Resident Buildings With Pilotis (필로티 건물 이격거리에 따른 화재확산 위험성 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.103-110
    • /
    • 2017
  • With the common tendency in the accordance with the trend, low-stories built edifices that are Pilotis-oriented structured exponentially and constantly increasing its number of buildings. It inevitably contains its risks of facing conflagrations as most of its part is used as parking lots. In the parking lots, the length of the flame has a heavy-weighted possibility that it would get increased because the heat release rate gets relatively high due to the vehicle insulation. Following on top of that, due to the nature of the Pilotisconsisting of pillars, there is a risk of flame spread to the adjacent building if the same Pilotis-structured buildings are adjacent to each other, if the flame spreads to the surroundings due to the influence of the wind. Because the most of the pilotis-structured-buildings have this entrance that makes the residents be able to enter, if the entrance were plugged the resident get a serious risk of a poisonous gas and a flame. Therefore, if the parking-lots of the pilotis-structured-buildings are adjacent to each other it requires a space to prevent the place from the spread of flame. This research studied how far is appropriate to prevent flame spreading with FDS. As a result, the study found that the distance at least 3.0 m is required.

Outbreak of Fire Blight of Apple and Asian Pear in 2015-2019 in Korea (2015-2019년 국내 과수 화상병 발생)

  • Ham, Hyeonheui;Lee, Young-Kee;Kong, Hyun Gi;Hong, Seong Jun;Lee, Kyong Jae;Oh, Ga-Ram;Lee, Mi-Hyun;Lee, Yong Hwan
    • Research in Plant Disease
    • /
    • v.26 no.4
    • /
    • pp.222-228
    • /
    • 2020
  • Erwinia amylovora, a causal bacterium of fire blight disease, is registered as a prohibited quarantine pathogen in Korea. To control the disease, the government should diagnose the disease, dig and bury the host trees when fire blight occurs. Fire blight was the first reported in 43 orchards of Anseong, Cheonan, and Jecheon in 2015, and 42.9 ha of host trees were eradicated. However, the disease spread to eleven cities, so that 348 orchards and 260.4 ha of host trees were eradicated until 2019. Fire blight of Asian pear occurred mainly in the southern part of Gyeonggi, and Chungnam province, on average of 29±9.2 orchards per year. And the age of the infected trees were mostly 20-30 years old. In apple trees, the disease occurred mainly in the northern part of Gyeonggi, Gangwon, and Chungbuk province, on average of 41±57.6 orchards per year, increased highly in 2018 and 2019. The age of infected apple trees were under 20 years old. Therefore, because the disease spread rapidly in young apple trees, spraying control agents to the trees in a timely manner and removing infected trees quickly are important to prevent the spread of fire blight in the orchard of immature trees.

A Study on the Formations of Thermal Stratification of Furniture Fire (가구화재시 열적성층의 형성에 관한 연구)

  • 허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.24-29
    • /
    • 1996
  • The objective of this research is to study on the formations of thermal stratification in a room in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. When fire spread to only one direction, like the case for the trashcan with a regular shape, there was one peak of temperature profile, and for the irregular shaped furniture such as chair, sofa, mattress and wardrobe, there were two or more peaks. The interface heights for the furniture fires were around 1(m) mataining constant state. However, at the time of the maximum temperature, the interface height was lowered to 0.25(m)-0.75(m) from the floor

  • PDF

Flow Characteristics of Fire Whirl for Different Heat Release Rate (발열량의 차이에 따른 Fire Whirl의 유동특성)

  • Bae, Sung-Yong;Sung, Kun-Hyuk;Ryou, Hong-Sun;Hong, Ki-Bae;Kim, Dong-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.609-613
    • /
    • 2008
  • The fire whirl occurring by the instability of atmosphere is a rare phenomenon, but highly destructive because it has high inhalation and lift force, caused by the rotating velocity. And it is difficult to extinguish the fire, because of increment of the spread rate with the flame height. In this study, for investigation of the flow characteristic of fire whirl for various heat release rate, numerical analysis is performed in same conditions with experiments, using the FDS which is developed at NIST. For validating of the numerical study, the results are compared with the experiment. The result shows that the relation between the characteristic length and the ratio of circulation versus the buoyancy force is $z_f$/D$^{\ast}$ = 0.304(${\Omega}/{\alpha}$)^2 - 1.334${\Omega}/{\alpha}$ + 5.516.

  • PDF

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

CFD-based simulation of fire-induced smoke and carbon monoxide transportation in the single compartment (CFD를 이용한 단일 구획 공간에서의 연기와 CO 확산 시뮬레이션)

  • Son, Yoon-Suk;Kim, Hyeong-Gweon;Oh, Hyung-Sik;Kim, Tae-Ok;Shin, Dong-Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.290-293
    • /
    • 2008
  • In this study, the Computational Fluid Dynamics (CFD) has been used to analyze the smoke movement and the carbon monoxide concentration distribution, both vertically and longitudinally, in a compartment, based on conservation laws. The Fire Dynamics Simulator (FDS) developed by National Institute of Standards and Technology (NIST) was used for numerical simulations using Reynolds averaged Navier-Stokes equations (RANS) model to solve for time-averaged properties. Results show, as a function of time, a detailed distribution of temperature and carbon monoxide concentration changing against the height above the floor and those changes alongside the distance away from the fire source. Fire-induced smoke and toxic gases like CO are more dangerous in a confined space. The result of study may contribute in designing the smoke evacuation system based on the precise tenable condition.

  • PDF

Study on the Ejected Plume from Opening Regarding Side-wall Effect in Fire (측벽효과를 고려한 개구부 분출화염 거동 연구)

  • Jeong, Jae-Gun;Shin, Yi-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.219-220
    • /
    • 2016
  • The behavior of fire plumes has not yet been clearly identified for cases where sidewalls are installed near an opening in an unconfined space. In this research, we aim to quantitatively identify the effects on fire spread when sidewalls are located on both sides of an opening. Specifically, we focus on the effects on the fire plume of the relation between the location of sidewalls and the opening, and carry out a scale-model experiment to devise a flame height model and to evaluate the temperature distribution along the central axis of the flame.

  • PDF