• 제목/요약/키워드: Fire smoke

검색결과 1,095건 처리시간 0.03초

급기가압 제연시스템의 현장 성능평가 연구 (Field Experiments on Performance Evaluation of Pressure Differential System for Smoke Management)

  • 김정엽;이동호;김하영
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.251-254
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The field experiments on two high buildings of 20 stories and 21 stories are carried out to evaluate the field performance of pressure differential systems for smoke management and the results of experiments are presented.

  • PDF

대심도 지하역사에서 화원 위치에 따른 연기거동 특징 연구 (THE STUDY ON THE CHARACTERISTICS OF FIRE DRIVEN SMOKE-FLOW FOR DIFFERENT FIRE-LOCATION IN DEEPLY UNDERGROUND SUBWAY STATION)

  • 김학범;장용준;이창현;정우성
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.202-207
    • /
    • 2009
  • 본 연구에서는 대심도 지하역사에서 화원 위치에 따른 연기거동의 특징을 분석하였다. 전산수치해석에 FDS code가 사용되었다. 화재에 의한 유체거동을 모사하기 위하여 난류모델은 LES를 사용하였으며, 빠른 계산을 수행하기 위하여 병렬수치해석기법을 사용하였다. 본 연구를 통하여 대심도 역사에서 화재시 피난을 저해하는 화원의 위치에 대하여 검토하였다.

  • PDF

화재 특성 고찰을 통한 농연 극복 센서 모듈 (A Sensor Module Overcoming Thick Smoke through Investigation of Fire Characteristics)

  • 조민영;신동인;전세웅
    • 로봇학회논문지
    • /
    • 제13권4호
    • /
    • pp.237-247
    • /
    • 2018
  • In this paper, we describe a sensor module that monitors fire environment by analyzing fire characteristics. We analyzed the smoke characteristics of indoor fire. Six different environments were defined according to the type of smoke and the flame, and the sensors available for each environment were combined. Based on this analysis, the sensors were selected from the perspective of firefighter. The sensor module consists of an RGB camera, an infrared camera and a radar. It is designed with minimum weight to fit on the robot. the enclosure of sensor is designed to protect against the radiant heat of the fire scene. We propose a single camera mode, thermal stereo mode, data fusion mode, and radar mode that can be used depending on the fire scene. Thermal stereo was effectively refined using an image segmentation algorithm, SLIC (Simple Linear Iterative Clustering). In order to reproduce the fire scene, three fire test environments were built and each sensor was verified.

성능위주 연기제어 설계지침 분석 (Analysis of Performance-based Design Guides of Smoke Control System)

  • 김정엽
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.6-13
    • /
    • 2016
  • 건축물에서의 연기제어 시스템과 관련하여 국내에서는 거실에 대한 배연기준과 피난계단 및 부속실에 대한 제연기준이 제시되고 있으나, 대형화 고층화 복합화 되어가는 첨단 건축물에 대한 적용성을 검토하면 국내 설계기준에 따른 연기제어 시스템은 화재시 연기안전을 확보하기 곤란할 수 있다. 따라서 대형 고층 복합의 첨단 건축물에 대한 화재시 연기안전성을 높이고 화재와 건축물 특성에 따른 상호 연기제어 연계성 확보와 통합적 설계가 가능한 성능위주 연기제어의 적용이 요구된다. 본 논문에서는 국내 연기제어 기준을 분석하고 개선이 필요한 부분을 제시하였으며, 선진외국에서의 성능위주 설계 수행에 대한 법체계와 성능위주 연기제어 설계의 지침을 조사하고 분석하였다.

열가소성 수지(PP, PMMA, PVC)의 연기생성 및 발생에 관한 실험적 연구 (Experimental Study on Smoke Production and Smoke Generation in Thermoplastic Resins Based on PP, PMMA, and PVC)

  • 황의홍;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.1-7
    • /
    • 2020
  • 건축물의 복잡화, 대형화로 인해 합성수지를 건축 재료로써 많이 활용되고 있다. 이에 따라 합성수지가 원인이 되는 화재의 발생이 증가하고 있다. 합성수지 화재의 특성으로는 연기 등 연소생성물로 인한 인명 및 재산피해가 크다는 점이고, 이는 연기생성과 발생과 관계된다. 이에 본 연구는 국내 건축 및 소방관계법령과 연기측정방법에 대해 검토하고, 연기관련 3가지 시험기준(ISO 5660-1, ISO 12136, ASTM E 662)을 바탕으로 실험을 실시하였다. 실험에 대한 결과로 연기생성 관련 데이터에서는 PP 43.27 ㎡, PVC 32.83 ㎡, PMMA 12.33 ㎡ 순으로 나타났고, 연기발생 관련 데이터에서는 PVC 27.855 g, PP 9.599 g, PMMA 6.975 g 순으로 나타났다.

분진을 이용한 연기감지기 신뢰성 분석에 관한 연구 (A Study on the Reliability Analysis for Smoke Detector using Dust)

  • 홍성호;최문수;이영만
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.11-16
    • /
    • 2013
  • This paper presents a study on the analyzing reliability of smoke fire detector using accelerated life test. In general, the smoke fire detector is broken by dust which flow in smoke detection chamber. In order to conduct accelerated life test of smoke fire detector dust is set accelerated factor in this paper. The dust is fly-ash which is test particle 5th regulated by KS A 0090. The dust accelerated level is 60 g, 180 g and 360 g and failure time is measured by smoke sensitivity testing. It is considered to failure of detector if detector don't operate within 30 secconds when subjected to an air stream having a velocity of 20 cm/s~40 cm/s containing smoke with a concentration of 15% of rate of light-response of 1 m. The goodness of fit test and mean life prediction conduct using the failure time. The result show that life distribution fits the weibull distribution for failure time data and the mean lifes calculate 22.5 year in domestic product and 14.7 years in overseas product applied dust stress only.

화재 조기 인식을 위한 화염 및 연기 검출 알고리즘 개발 (Development of Flame and Smoke Detection for Early Fire Recognition)

  • 박장식;김대경;최수영;이영성
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.27-32
    • /
    • 2008
  • 본 논문에서는 화재의 조기 감지를 위하여 카메라 입력영상으로부터 화염과 연기를 검출하는 알고리즘을 제안한다. 화염과 연기는 특정 색분포를 가지며 지속적으로 형태가 변화하며 움직인다. 제안하는 화염검출 알고리즘은 화염의 색분포와 영상 프레임간의 변화를 측정하여 후보영역을 설정하고 화염의 움직임벡터를 계산하여 화염을 확정한다. 연기에 의하여 영상의 고주파수 성분이 감소하기 때문에 경계값의 변화는 연기의 중요한 특징이다. 연기검출은 색분포, 영상 프레임간의 변화 그리고 경계를 이용하여 후보영역을 설정하고 움직임 벡터를 계산하여 결정한다. 컴퓨터 시뮬레이션을 통하여 제안하는 알고리즘으로 화염과 연기를 검출할 수 있음을 보인다.

Jet fan 근접 화재 발생 시 제연 특성 연구 (Study of the Smoke Control Characteristics for Fire Near Jet Fans)

  • 김종윤;서태범;임경범;유지오;이동호
    • 한국화재소방학회논문지
    • /
    • 제21권1호
    • /
    • pp.82-89
    • /
    • 2007
  • 본 연구에서는 Jet fan 근접 거리에서 화재 발생 시 최소거리의 Jet fan을 이용하여 연기를 제어하기 위하여 PIV에 의한 가시화실험을 실시하였고, 또한 실험을 통해 얻어진 결과와 FDS 수치해석 그 결과를 비교, 분석 하였다. 터널 내 화재발생 시 Jet fan 설치에 따른 효율적인 연기제어 방식의 정량적 데이터 분석 결과 근접 Jet fan의 작동은 화원과 25m 이상의 거리에서만 가동해야 한다. 또한 Jet fan과 화원의 이격거리가 50m 부근에서 가장 안정적으로 연기가 제어되며 75m 이상의 거리에서는 터널 중앙 부근에서 과풍속 경향이 나타나며 제연되었다.

다양한 화재조건에서 플라스틱 종류에 따른 연기입자의 크기분포 변화 측정 (Measurement of the Size Distribution of Smoke Particles with Plastic Types Under Various Fire Conditions)

  • 구재학;황철홍
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.8-15
    • /
    • 2017
  • 화재발생 시에 대부분의 인명 피해는 연기에 의해 발생되는데, 최근 건축 내장재에서 차지하는 플라스틱의 양이 많아지며 발생되는 연기의 유독성이 점차적으로 증가되고 있다. 연기에 의한 인체피해의 상당부분은 흡입연기의 폐침전과 관련이 있으며, 연기입자의 크기분포는 폐침전 특성에 직접적인 영향을 미친다. 따라서 플라스틱 종류에 따른 연기입자의 크기별 발생량 검토는 폐침전에 의한 인체피해 연구에 필수적으로 요구된다. 최근의 목재와 폴리프로필렌(PP)에 대한 연기입자의 발생특성 연구에서 PP의 연기입자 크기분포 특성이 몇 가지 측면에서 목재와는 확연히 다르게 나타났다. 이에 따라, 본 연구에서는 다른 플라스틱들도 연기입자 크기분포에서 PP와 같은 특성을 보이는지 알아보기 위해서 대표적인 4가지 플라스틱(LDPE, PA66, PMMA, PVC)에 대하여 연기입자 크기분포 측정실험을 수행하였다. 특정 조건에서 연소생성물을 균일하게 생성하고 분석하기 위하여 ISO/TS 19700 기준에 따른 등속튜브연소로를 이용하여 연소로의 온도와 산소공급량에 따라 다양한 화재조건에서 연기입자를 균일하게 발생시키고, 정전저압 임팩터를 사용하여 연기입자의 크기에 따른 개수농도를 실시간으로 측정하였다. 실험 결과 4가지 플라스틱의 연기입자 크기분포 특성은 여러 측면에서 PP와 유사하며 목재와는 확연히 다르게 나타났다.

랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구 (An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses)

  • 최기옥;김동석;홍성호
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.