• Title/Summary/Keyword: Fire service law

Search Result 34, Processing Time 0.021 seconds

A Study on the Fire Prevention of Temporary Constructions Connected with Factory Buildings (공장건물에 연결된 가설건축물 화재예방에 관한 연구)

  • 이정용;이창섭
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.68-75
    • /
    • 2003
  • Temporary constructions are defined as constructions for temporary use, but frequently they are used long like permanent constructions and connected with main constructions. In this case, fire hazardousness increase. But there is no way to control this hazard in our system. This study include investigation of present related law survey about sample complex, collection of related lawsuit result and estimation of hazardousness of each contemporary construction type. The conclusion is that the article that specify distance between main construction and temporary one should be created in the architectural law. Or to apply fire service law to area of temporary construction, fire service law should be changed properly.

A Study on the Policy Tasks for the Development of National Fire Service - Redesigning Institutional and Organizational Improvement for the Establishment of the National Fire Service Agency - (한국소방발전을 위한 정책과제 연구 - 소방청 신설에 대응하는 제도·조직개선 구상 -)

  • Choi, Byoung-Hahk;Kim, Hak-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.185-197
    • /
    • 2002
  • Today, the basic problem of functional safe management of Korean Disaster Control system was separately administrated 33 acts that are relating to safe management in 13 ministries. Because of the facts that the fire service is not provided practically, the control system and risk management for safe administration are not operated, the information can not be shared with each other, and the various laws have the lacks of linkage, the National Safe System was appeared unsteady. The roles and functions of fire service have started with restriction to operate structurally and institutionally, which operational structure of fire service is becoming weak. As a result, the federal and local fire organizations have not reached yet to the institutionalization and the local fire service agencies have bias with the task regarding the fire service because of the relation between organizational structure and the local fire agency. With the enforcement of the federal and local fire system, professionality and autonomy for making policy, and dealing with changes of fire service positively, the national fire service on the policy performance can be established. Promotion of research and development and education training to strengthen innovation in technology and competition in fire industry will contribute to the firmly establishment of control system to prevent from fire, flood, terror and national disaster. This article proposed that (a) the established law and administration, agency are required efforts to effectively operate fire service system; (b) the national fire service agency, national college of fire, national institute of science fire, and national fire service hospital should be early established to make firmly policy to operate effectively and practically. These kinds of innovational acts are known the best ways of operating solid policy of national fire service system.

  • PDF

A STUDY ON THE FLAMMABILITY OF NON-FLAME-RETARDANT AND FLAME-RETARDANT MATERIALS BY USING CONE CALORIMETER

  • Yanai, Eiji;Suzuki, Takeshi;Yamada, Tokiyoshi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.85-92
    • /
    • 1997
  • Flammability of non-flame-retardant and flame-retardant materials was studied by using cone calorimeter Also, relations between the results obtained by using cone calorimeter and those obtained by the flammability test of japanese fire Service Law were examined. The results are as follows: 1) The ignition time of the molten specimens is relatively long, whereas the ignition time of the non-molten specimens is short. None of remarkable difference of the ignition time has been found between non-flame-retardant and flame-retardant materials specimens. 2) The peak heat release rates of flame-retardant materials are smaller than those of non-flame- retardant materials. 3) The carbon monoxide and smoke evolved from flame-retardant materials generate much more than those evolved from non-flame-retardant materials. 4) Even if flame-retardant materials are passed by the flammability test of Japanese Fire Service Law, they burn easily under external radiative heating condition.

  • PDF

A study on the Improvements of the Fire Officials' Employment (소방공무원 공개채용 시험과목 조정에 관한 연구)

  • Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.153-161
    • /
    • 2008
  • The duty of fire officials are very complicated and various that a subject replacement for the fire officials' public examination for service is being required. The purpose of this study is to investigate the actual conditions of the fire officials' public employment system and find out current problems of it, to reconsider the speciality of the examination based on them, and to suggest a subject replacement for the examination to evaluate the duty accomplishment ability. This study presents not only assuring the speciality of fire officials but also the desirable plans to execute the Fire Relating Act effectively by replacing introduction of political science with fire service administration and adding the Fire Relation Law which is more connected on the local fire officials public written examination for service with duty.

Study on Hazard of Toner Cartridge at Recycle Facilities

  • Koseki, Hiroshi;Iwata, Yusaku;Lim, Woo-Sub
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.15-18
    • /
    • 2012
  • Because of development of printing technology, toner cartridge particle becomes smaller and more dangerous. And sometimes we had incidents with dust explosion of toner cartridge particle at recycling facilities in Japan. Therefore we studied on hazard of toner particle relating with dust explosion. We found that toner particle is so dangerous compared with most organic solids, even though it does not belong to hazardous materials in the UN regulation and the Japanese Fire Service Law.

Related Laws and Performance Criteria for Public Service Drones for Disaster Safety (재난안전드론 도입을 위한 법규 및 성능기준 기초연구)

  • Kim, Noh Joon;Lee, Sung Eun;Kim, Hwang Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.150-155
    • /
    • 2016
  • This study is to suggest legislation and criteria for public service drones for disaster safety in order to enhance the research and development of the drones by helping setting right direction of the R&D. Many foreign governments are now conducting research and development on using drones as public service for disaster safety. Although there are also some efforts to using drones for public service in Korea, domestic laws and performance criteria for the drones for the purpose have not prepared yet. To set a right direction of the R&D, the laws and criteria shall be legislated and established immediately and then we can enhance the efforts to develop related technology for the drone. So this study proposed a performance criteria to fit various circumstances and situations by analyzing the aviation law in overseas. We hope this study can help R&D on the public service drones for disaster safety.

The Study About the Installation of Fire-fighting Office by the Local Government (기초지방자치단체의 소방기관설치에 관한 연구)

  • 전경배
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.31-44
    • /
    • 2003
  • In the Local Autonomy Law, we regard the fire-fighting service as inherent service for the local government. However, if we look into the course of the charge of fire-fighting service, after the transfer of this from the police service, or the state, to the local service in 1991, this is now taking a firm hold as service of the local government. what we call the local services includes the business about the welfare of the residents and that of taking in charge of the resident properties, proclaimed in the Constitution. That is to say, the basic purpose of the local autonomy is to make the residents feel the most convenient and safe, and this is the mission of the present-day local autonomy. Looking from this point of view, if we consider that the ultimate purpose of fire-fighting is promoting the welfare of the residents by preventing and putting out fires and, in the time of emergency, carrying out rescue and relief operations, and furthermore, maintaining the safety and order of a society, until present time the benefits of fire-fighting business were mainly available to the residents of the cities. In order to break from these thoughts, according to the result of comparing and analyzing the metropolitan city, surrounding rural areas, middle and small cities and typical rural areas, the rural areas are urgently demanding fire-fighting service, so it is being proved that it is necessary to install the offices in these areas. Therefore, the installation of the fire-fighting offices in the counties that are the basic units of the primary local autonomy and are rural areas should be expanded as part of the welfare administration.

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.

A Study on the need of the Conversion of Fire Services to State Affairs (소방사무의 국가사무로의 전환 필요성에 관한 연구)

  • Lee, Jae-Hak;Jang, Seong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.7
    • /
    • pp.281-290
    • /
    • 2021
  • The scope of fire services has been expanded from local fire prevention to rescue and first aid services, and the fire services system has been converted from an autonomous fire services system to a wide-area fire services system, and the status of fire officers has been unified as a national public servant. However, the underlying problem remains unsolved. One is a problem related to the conversion of fire services to state affairs, and the other is that Fire officers converted to national public servants are in charge of fire services which are evaluated as local autonomous affairs. The controversy over the nature of fire service stems from uncertainty and redundancy in the coordination of office function and distribution between the State and Local governments, and incomplete legislation that fundamentally fails to achieve systematic unity of office work and status. The fire service has a national responsibility as an affair that includes the existence of the state and the welfare and order of the people along with the police affairs. That is, affairs related to the safety of the people that protect the lives, bodies and properties of the people should be understood as State affairs. 「The LOCAL AUTONOMY ACT」 stipulates that local governments cannot perform State affairs such as affairs necessary for the existence of the nation, affairs requiring performance in a uniform manner throughout the nation, and affairs of nationwide or similar scale unless otherwise provided by the law. Fire Service should be regarded as such affairs. Considering that the rights to the safety and life of the people and the duty to protect the people are the duty of the nation, it is necessary to keep in mind that the reason for the change fire officers to the national public servants was not basically just a matter of treatment and finance.

Study of the Improvement Method of a Hazardous Materials Classification System for the Introduction in GHS (GHS제도 도입에 따른 위험물 분류체계의 개선방안)

  • Lee, Bong-Woo;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.108-115
    • /
    • 2017
  • This study evaluated a preventive information communication system for the storage, handing, and transportation of hazardous materials according to the hazardous materials safety management law of Korea. At present, the chemical management system has very little information on accident responses due to a problem in the initial response. Therefore, this study was designed to improve the hazardous materials safety management law as an advanced method for simultaneous accident prevention and response, such as GHS system. This can also cause confusion in industry, such as manufacturing and import-export companies, because safety management laws and the GHS system are very different from the hazard classification systems. This study suggests a harmonization plan between the hazardous materials safety management law and the GHS classification system through an analysis of the hazardous materials classification system of major advanced countries.