• Title/Summary/Keyword: Fire safety design

Search Result 675, Processing Time 0.034 seconds

A Study on the Fire Risk Assessment : Based on the Proposal of a Fire Risk Assessment Processor Considering the Reality in Korea (화재위험도 평가에 대한 연구 : 국내 현실을 고려한 화재위험도 평가 프로세서 제안을 중심으로)

  • Lee, Jong Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.57-64
    • /
    • 2021
  • Recently, advanced countries assessment the risk of fire to prevent large-scale damage to high-rise buildings, In addition, performance-Based design, which is a fire risk assessment, is being conducted in Korea to prevent massive damage to high-rise buildings. However, unlike advanced countries, fire risk assessment in Korea is subject to fire risk assessment only for objects subject to consent from fire-fighting facilities such as building permits, When building engineers and fire-fighting engineers assessment the risk of fire, It has always been discussed because the results vary depending on which part of the evaluation is focused between economic feasibility and safety. Therefore, in this study, we would like to propose a fire risk assessment process suitable for domestic conditions by comparing the process of performance-based design, which is a domestic fire risk assessment, and the process of Iso/TC 16732 which is an overseas fire risk assessment.

A Study on the Appropriateness of Design Fire Size Determining for Performance Based Design in Korea (국내 성능설계에서 선정된 설계화재의 적정성 연구)

  • Lee, Se-Myeoung
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.50-56
    • /
    • 2014
  • The quantification of fire size in buildings must be preceded in order to design the trial of performance based design (PBD). When design fire size is determined appropriately, the trial design will become economical and safe design against fire risk. There are many problems in determining design fire size because of lacks of fire engineering data and short history of PBD in korea. Therefore, this paper has surveyed the guideline of design fire in other countries, real experimental data for a few occupancies and the cases of design fire size determining for PBD in Korea. Also, it has proposed the guideline of design fire size for various occupancies in korea after analyzing the appropriateness of design fire size.

A Study on the Fire Safety Design of High-Rise Apartment Housing in Korea (초고층 아파트의 화재안전계획에 관한 연구)

  • 최인석;박윤성
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.15-22
    • /
    • 1991
  • After the appearance of apartments in Korea, Apartment Housing has been generally accepted for its high capacity of population and convenience in the management. Nowadays, apartments have become higher, larger and more complex than ever before, showing abrupt changes in structure, form and mechanical systems. Likewise, the hazards of fire and the scale of fire losses have become a serious problem. Therefore. considerations of fire safety have taken a greater portion in the design of Apartment Housing. This study is focused particulary on spatial planning rather than on mechanical systems for fire safety.

  • PDF

A Study on Powder Fire Extinguisher Design with RULA Technique Used (RULA 평가기법을 활용한 분말소화기 디자인 연구)

  • Kang, Chaewoo;Kim, Dueknam
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

An Improvement Study on National Fire Safety Code of Sprinkler System for Hydraulic Calculation Application (수리계산 적용을 위한 스프링클러설비의 화재안전기준 개선방안 연구)

  • Lee, Keun-Oh;Kang, Joo-Hyeong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.7-12
    • /
    • 2007
  • There are two kinds of design process for sprinkler system. one is pipe schedule system and the other is hydraulically designed system. We have inefficient results when we design by hydraulically designed system because the design process for sprinkler system is restricted by domestic fire code. Therefore, it is essential to do an introduction of hydraulically designed system which is based on engineering for enhancing reliability and efficiency of sprinkler system. This study presents points at issue by comparing and studying design standards of sprinkler system from Korea, Japan and NFPA, and presents improvement plans of national fire safety code of sprinkler system by processing, comparing and analyzing designs according to piping schedule and hydraulically designed system about domestic objects. Installation standards of sprinkler system have to be applied not by object buildings but by hazard classification. It is hard to design an efficient sprinkler system for fire control when water supply requirement of sprinkler systems allocated according to a size of a building because the same purpose but other buildings may request more water requirement or less. We should sublate the pipe schedule system from national fire safety code and need to introduce the hydraulically designed system. The pipe schedule system presents easy access because it is based on the forecasted engineering calculations but it is applied to only small buildings like NFPA due to its low reliability.

A Study on the Fire-Safety and Escape plan of Hotel Design (호텔건축의 화재안전과 피난계획에 관한 연구)

  • 김기만;박윤성
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 1988
  • Due to its commercial, ceremonial function, the hotel design has a tendency to be higher and larger, and its form being varied. But this tendency is not desirable in respect of architectural fire-safety. The higher its height and the larger its mass becomes, relatively the damage expectation becomes. Moreover, in case of fire, it is expected that many serious problems break out, because the users of a hotel, unlike those of office building or housing, are majority of unspecified people and they have no information about that building. Therefore, this study dealt with fire-safety problem in hotel design and tried to find out countermeasures of fire-safety and successful escafe against fire.

  • PDF

A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System (소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

Study for the Method to Secure the Safety of Fire-fighters in the Building Damaged by a Fire by Using Fire-resistant Design Theories - Mainly about Suggesting the Process and the Method for a Real-time Safety Evaluation by a Fire-fighter - (화재손상 건축 구조물에서 내화설계 이론을 활용한 소방관 안전확보 방안에 관한 연구 - 소방관에 의한 실시간 안전성평가 절차 및 방법의 제안을 중심으로 -)

  • Kwon, Yeongbae;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.86-95
    • /
    • 2016
  • Weight-bearing building materials are substantially weakened under high temperatures, and this is evident through the collapse of structures once engulfed by fire. Currently, there is no scientific or technological process of evaluating the real-time structural stability of a building whcih is engulfed by flame. There are many building design specifications which aim to reduce the risk of fire, but little consideration given to fire officer safety while operating in a dangerous building. This paper aims to provide direction within building policy in order to ensure the safe evacuation of fire-fighters in case of an impending building collapse. This paper suggests evaluation criteria for buildings which are damaged due to fire, autilizing current information on fire-resistant building design and a fire-resistant capacity.

A Study on the High-rise Apartment Balcony Plan for Egress Safety Design (고층 공동주택의 피난안전을 위한 발코니계획에 관한 연구)

  • 이용재
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.63-69
    • /
    • 2001
  • Applying a life safety concept to apartment design procedure is essential to protect people from unwanted fire. A Balcony design in apartment is a important egress safety factor because it provide means of safe egress and can limit a flame spread to adjacent space from fire source. Some design principles and details of balcony plan are suggested to improve egress safety level with analyzing broad case study.

  • PDF

Heat Release Characteristics of Typical Live Fire Load in Large Bookstore (대형서점 적재가연물의 초기 연소발열성상)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book. Based on the results, it has reviewed fire safety when a fire accident occurs on the large bookstore and suggested peak heat release rate per burning surface, fire growth rate, etc of the live fire load required for fire safety design in bookstore.