• Title/Summary/Keyword: Fire response system

Search Result 253, Processing Time 0.027 seconds

An Experimental Study on the Responsiveness of Sprinkler Heads (스프링클러헤드 응답성에 관한 실험적 연구)

  • 김동석;박용일;박희용
    • Fire Science and Engineering
    • /
    • v.7 no.2
    • /
    • pp.3-12
    • /
    • 1993
  • The closed type sprinkler head is a component of sprinkler system for fire protection. The purpose of this study is to inverstigate the influence factors of the responsiveness of the head by heated wind tunnel experiment. As the result of this study, it was found that response time index and conduction parameter showed the same characteristic quantitative changes to head types and test methods.

  • PDF

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.

  • PDF

The Seismic Design of Water Extinguishing Piping Systems for Equivalent Static Analysis Method (등가정적해석법에 의한 수계 파이프 시스템의 내진설계)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.100-105
    • /
    • 2012
  • In this study, seismic design in pipeline of pressurized water supply system of water extinguishing system has been carried out. This study described a generation of artificial earthquake wave compatible with seismic design spectrum, and also determined equivalent static loads to analyzed the response spectra acceleration by the simulated earthquake motion. This study constructed powerful engineering base for seismic design, and presented equivalent static analysis method for seismic design of water and gas extinguishing piping system. Also, this study readied basis that can apply seismic design and performance estimation of fire fighting system as well as pipeline of water extinguishing system from result of this research. Hereafter, if additional research by earthquake magnitude and ground kind is approached, reliance elevation, safety raising and performance based design of fire fighting system see to achieve.

A study on the Fosterage Finance Cooperative System Considering the Characteristics of Fire Protection Industry (소방산업의 특성을 고려한 금융공제시스템 육성에 관한 연구)

  • Jung, Jung-Ki
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.97-108
    • /
    • 2010
  • Recent patterns of diversification of a disaster, depending on the size of the larger trend, quick and efficient response to disaster prevention, to increase the importance and role of advanced equipment and technology of fire protection industry is becoming more, over market size 11 trillion won and 10 million workers in industries of national importance, but to exceed, As most SMEs compared to other industries are backwardness. Therefore, in this study closely the characteristics of the fire protection industry analysis, the systematization of theoretical models of the finance cooperative system considering the characteristics of fire protection industry and provider the fosterage, they will contribute to independent economic activity and industrial development for operators to use the finance cooperative system of fire protection industry.

Proposal of safe fire escape system for the day-care center and the kindergarten (어린이집 및 유치원의 화재 대피용 안전 경로 시스템 제안)

  • Choi, Jun-Ho;Kwon, Mee-Rhan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.297-301
    • /
    • 2015
  • Day-care centers and kindergartens are increasing along with the damage caused by fire year after year. Infants and toddlers have a low response capability than adults to fire situations such as heavy smoke which causes less or zero visibility thus it is difficult in evacuation route during dangerous fire situations. Because of these circumstances, teachers need to build a safe pathway signage system along with the usual fire safety training needs of infants and children. In this paper, we propose a system for fire escape which marks the escape routes and are automatically implemented through the push function that smartphone recognizes during the real-time fire situation, and establish a system that verifies its authenticity.

A Study on Integrated Fire Alarm System for Safe Urban Transit (안전한 도시철도를 위한 통합 화재 경보 시스템 구축의 연구)

  • Chang, Il-Sik;Ahn, Tae-Ki;Jeon, Ji-Hye;Cho, Byung-Mok;Park, Goo-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.768-773
    • /
    • 2011
  • Today's urban transit system is regarded as the important public transportation service which saves passengers' time and provides the safety. Many researches focus on the rapid and protective responses that minimize the losses when dangerous situation occurs. In this paper we proposed the early fire detection and corresponding rapid response method in urban transit system by combining automatic fire detection for video input and the sensor system. The fire detection method consists of two parts, spark detection and smoke detection. At the spark detection, the RGB color of input video is converted into HSV color and the frame difference is obtained in temporal direction. The region with high R values is considered as fire region candidate and stepwise fire detection rule is applied to calculate its size. At the smoke detection stage, we used the smoke sensor network to secure the credibility of spark detection. The proposed system can be implemented at low prices. In the future work, we would improve the detection algorithm and the accuracy of sensor location in the network.

  • PDF

Methodology of Emergency Power System by the Minimum Response Time Based on IEC Standards (IEC규격을 부합화한 최소응답시간에 따른 비상전원시스템의 구축방안)

  • Son, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.23-32
    • /
    • 2011
  • When the power outage occurred, the emergency power equipments are demanded instead of disaster prevention and security electric power. However, in domestic area, the rules and regulations of emergency power equipment are different so we use different terminologies. Thus, this paper proposes differences of rules and regulations of emergency power equipment between domestic and foreign countries about terms and concepts. Also, we found some problems of the emergency power equipment. To solve these problems, according to the minimum response time in IEC standards, we suggest five emergency power systems and fire load classification in this paper.

Study on Cases of Priority Traffic Signal System for Emergency Vehicles: Based on a City's Pilot Operation Cases in Chungcheongbukdo Province (긴급차량 우선교통신호시스템 사례에 관한 연구: 충청북도 내 일개도시 시범운영 사례를 중심으로)

  • Kim, Jin-Hyeon;Lee, Hyo-Ju
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.121-126
    • /
    • 2020
  • The aim of this study is to suggest ways to capitalize on the golden period for timely response to fire and emergency victims. To implement a system to effectively capitalize on the golden period, there is a need for policy measures as well as legal and social consensus. Precedent research has relentlessly mentioned the need for and feasibility of the priority traffic system for emergency vehicles. To this end, the present study involved an analysis of pilot cases of the priority traffic signal system for emergency vehicles introduced in a city during 26 days, from April 3 to 28, 2017. Out of 58 cases registered with the local 1-1-9 fire house, the number of cases that took advantage of the priority traffic system stood at 16 in response to fire and 11 to first-aid operations. Owing to the system, on average, the response time reduced by 3 min and 50 s in case of fire and by 3 min and 30 s for first aid. There were four complaints registered owing to traffic congestion, and the number of car accidents declined to one from six over the same period in the previous year. Based on these findings, it is safe to say that the priority traffic signal system would be effective for emergency vehicles to capitalize on the golden period if issues identified during the pilot run are resolved.

Development of 119 Integrated Emergency Management System Training Simulator System (119 긴급구조시스템 교육훈련 시뮬레이터 개발)

  • Chung, Byung-Ho;Shin, Jae-Hong;Cho, Ung-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.461-467
    • /
    • 2015
  • 119 Integrated Emergency Management System, 119 IEMS hereinafter, is specialized command and control system for fire H.Q., that supports effective response activity at Fire, Rescue, and First Aids; it covers the emergency call taking, dispatch command delivery and situation control after dispatch command. While the efficiency of emergency response activity of call-taker and dispatcher is directly linked to the capability of qualified response in protecting the life and properties at real-time emergency condition, there is not any similar simulator system that can be used for training purposes for newly allocated personnel or beginner of emergency call taking and dispatch activity - 119 IEMS in fire H.Q. is the operation system that cannot be shared with other purposes, and they're highly expensive ICT system and infrastructure to be used as training and education. 119 Integrated Emergency Management Simulator System, 119 IEMS Simulator, was developed to be utilized in low cost for the training of 119 emergency call taker and dispatcher, and it can be used in training of various types of disaster and emergency handling, spans to emergency call taking, dispatch command, and field report and situation control after dispatch command.

Case Analysis of the Harmful Chemical Substances' Spill (유해화학물질 유출의 사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.90-98
    • /
    • 2014
  • Lately accidents of harmful chemical substance in korea were repeatedly replaying. We studied problems and preparation plan in 2008 years~2014 years through analysis cases of harmful chemical substance. Leakage of chemical substance's accident situation shows that leakage in the workplace is the most 10 cases, accounting for 58.6% is the largest proportion in 2009. Leakage according to explosion accounting for 50% (5 cases) in 2004, 25% (4 cases) in 2007 and 33.3% (4 cases) in 2011 has very irregular change. Therefore, A major cause of accidents is lack of safety management. Harmful chemical substance showed various aspects, high residual substance and non-visible characteristic so response and recovery was easy. And the second damage to move a distance causes environment pollution. So a mutual-assistance system and integrated system of related organization have to build and expert of chemical incident response and therapist of chemical substance response have to establish to do efficient and rapid response.