• 제목/요약/키워드: Fire response

검색결과 600건 처리시간 0.031초

전기차 화재 실험 및 대응방안에 관한 연구 (An Experiment Study on Electric Vehicle Fire and Fire Response Procedures)

  • 남기훈;이준식
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.63-70
    • /
    • 2024
  • Lithium-ion batteries (LIB) are widely used in various sectors, such as transportation (e.g., electric vehicles (EV)) and energy (e.g., energy storage facilities) due to their high energy density, broad operating temperature (-20 ℃ ~ 60 ℃), and high capacities. LIBs are powerful but fragile on external factors, including pressure, physical damage, overheating, and overcharging, that cause thermal runaway causing fires and explosions. During a LIB fire, a large amount of oxygen is generated from the decomposition of ionogenic materials. A water fire extinguisher that helps with cooling and suffocating must be essentially required at the same time. In fact, however, it is difficult to suppress LIB fires in the case of EVs because a LIB is installed with a battery pack housing that interrupts direct extinguishing by water. Thus, this study aims to investigate effective fire extinguishing measurements for LIB fires by using an EV. Relevant documents, including research articles and reports, were reviewed to identify effective ways of LIBs fire extinguishing. A real-scale fire experiment generating thermal runaway was carried out to figure out the combustion characteristics of EVs. This study revealed that the most effective fire extinguishing measurements for LIB fires are applying fire blankets and water tanks. However, there is still a lack of adequate regulation and guidelines for LIB fire extinguishment. Taking this into account, developing functional fire extinguishment measurements and available regulatory instruments is an urgent issue to secure the safety of firefighters and citizens.

구급대원의 재난대응역량에 관한 연구 (Study on disaster response competencies of 119 EMTs)

  • 이정혁;이경열
    • 한국응급구조학회지
    • /
    • 제22권3호
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose: This study was conducted to investigate the disaster response competencies of 119 emergency medical technicians (EMTs). Methods: The subjects of this study were 226 119 EMT's at the fire station located in G province. The questionnaire consisted of 5 sub-factors and 29 items for measuring disaster response competencies and the collected data were analyzed using SPSS program. Results: Disaster response competency comprising immediate response, patient triage, patient treatment, patient transport, and collaboration support were 3.48, 3.64, 3.52, 3.64, and 3.16, respectively. Advanced EMTs scored significantly higher in patient triage (p<.001), treatment (p<.001), and transport (p=.022) competency than basic EMTs. Conclusion: In order to improve disaster response competency, it is necessary not only to enhance individual ability but also to continue disaster management training with related organizations.

Experimental Study on Fire Hazard of Residential Fires Before and After Sprinkler Activation

  • Sekizawa, Ai;Yanai, Eiji;Takemoto, Akio;Kozeki, Daisuke;Suzuki, Keiko
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.376-383
    • /
    • 1997
  • Fire experiments were conducted in a real scale room which is assumed to be a residential living room under the various opening conditions and locations of wood crib fire source to study on fire hazard before and after sprinkler activation. Concentrations of oxygen and carbon monoxide, smoke density, and temperature were measured to look into environmental conditions in a room of fire origin. The response time of residential sprinklers was also examined in relation to distance between sprinkler heads and a fire source.

  • PDF

소방조직의 안전기능강화를 위한 AHP를 활용한 서울특별시소방학교 교육훈련프로그램 분석 (An Analysis of the Educational Training Program of Seoul Fire Academy through AHP for the Strengthening of Fire Fighters' Safety Function)

  • 김진근;박찬석
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 추계학술대회
    • /
    • pp.299-320
    • /
    • 2013
  • In recent years, the surroundings of Fire have rapidly changed and citizens need for Fire have been demanding very high. Under these situations, in order for satisfaction to all these demands, Seoul Metropolitan Government Fire Academy(SFA) have only to improve its educational training program as the fire educational training center in Korea. The purpose of this study is to scrutinize current educational training program of SFA and measure the relative weight among the hierarchy of disaster management(prevention and mitigation-prepare dness-response-recovery) by using the Analytic Hierarchy Process(AHP). The result of this study presents that how many hours must be allocated and set the educational training program with scientific and systematic way of AHP compared the current program of SFA in 2013. And This study is applied to increase access and comprehension about the AHP and will be able to present guideline for the selection of optimal the educational training of SFA to serve Seoul citizens the best Fire services.

  • PDF

Numerical analysis on the behaviour of reinforced concrete frame structures in fire

  • Dzolev, Igor M.;Cvetkovska, Meri J.;Ladinovic, Dorde Z.;Radonjanin, Vlastimir S.
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.637-647
    • /
    • 2018
  • Numerical approach using finite element method has been used to evaluate the behaviour of reinforced concrete frame structure subjected to fire. The structure is previously designed in accordance with Eurocode standards for the design of structures for earthquake resistance, for the ductility class M. Thermal and structural response are obtained using a commercially available software ANSYS. Temperature-dependent nonlinear thermal and mechanical properties are adopted according to Eurocode standards, with the application of constitutive model for the triaxial behaviour of concrete with a smeared crack approach. Discrete modelling of concrete and reinforcement has enabled monitoring of the behaviour at a global, as well as at a local level, providing information on the level of damage occurring during fire. Critical regions in frame structures are identified and assessed, based on temperatures, displacements, variations of internal forces magnitudes and achieved plastic deformations of main reinforcement bars. Parametric analyses are conducted for different fire scenarios and different types of concrete aggregate to determine their effect on global deformations of frame structures. According to analyses results, the three-dimensional finite element model can be used to evaluate the insulation and mechanical resistance criteria of reinforced concrete frame structures subjected to nominal fire curves.

A Simplified Steel Beam-To-Column Connection Modelling Approach and Influence of Connection Ductility on Frame Behaviour in Fire

  • Shi, Ruoxi;Huang, Shan-Shan;Davison, Buick
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.343-362
    • /
    • 2018
  • A simplified spring connection modelling approach for steel flush endplate beam-to-column connections in fire has been developed to enable realistic behaviour of connections to be incorporated into full-scale frame analyses at elevated temperature. Due to its simplicity and reliability, the proposed approach permits full-scale high-temperature frame analysis to be conducted without high computational cost. The proposed simplified spring connection modelling approach has been used to investigate the influence of connection ductility (both axial and rotational) on frame behaviour in fire. 2D steel and 3D composite frames with a range of beam spans were modelled to aid the understanding of the differences in frame response in fire where the beam-to-column connections have different axial and rotational ductility assumptions. The modelling results highlight that adopting the conventional rigid or pinned connection assumptions does not permit the axial forces acting on the connections to be accurately predicted, since the axial ductility of the connection is completely neglected when the rotational ductility is either fully restrained or free. By accounting for realistic axial and rotational ductilities of beam-to-column connections, the frame response in fire can be predicted more accurately, which is advantageous in performance-based structural fire engineering design.

도로터널 화재시 효과적인 소방활동전략 수립을 위한 시나리오 연구 (Scenarios for Effective Fire Fighting Operations during Tunnel Fires)

  • 김학근;이지희
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.107-116
    • /
    • 2017
  • 터널화재는 국제적인 관심사이며, 매년 중대 터널화재는 발생하고 있다. 교통밀도가 증가하면서 장대터널은 물론, 더 많은 수의 터널이 건설되고 있어서, 앞으로 터널화재의 잠재위험성이 더 나빠질 수 있으므로 더욱더 심각한 문제이다. 도로터널 화재발생시 소방대원이 효과적인 소방활동 전략을 수립하도록 하는 것이 본 연구의 궁극적 목적이다. 과거 화재 사례로부터 어떠한 사고가 발생하였고, 어떠한 소방활동이 행해졌는지 알아보기 위하여 국내외 73건의 터널화재사고사례를 조사하여 4가지 사고유형으로 분류하였다. 소방활동의 전략수립을 위해 개입시간과 열방출율의 관계로 6가지 화재시나리오 곡선을 도출하였다. 이것은 두 가지 기준 즉, 반응한계와 최대 도착시간에 따라 소방활동의 전략을 수비적, 공격적 전략 중 선택할 수 있도록 하였다. 도로터널 분류 모델은 각 소방기관이 관할 터널의 화재 위험 정도를 화재 진압의 관점에서 평가하고 예방조치를 수립하는데 사용될 수 있다.

지하공동구 화재예방활동 및 진압대책에 관한 연구 (A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit)

  • 이정일
    • 한국방재학회 논문집
    • /
    • 제10권4호
    • /
    • pp.63-68
    • /
    • 2010
  • 지하공동구는 도시 및 공동주택 단지에 반드시 필요한 전력, 통신, 가스, 송유관, 급 배수, 에너지시설 등을 효과적으로 수용하고 도시기반시설의 확장에 따라 파생되는 여러 가지의 문제점을 해결하기 위한 방안으로 시설물을 한곳으로 모아 유지 및 관리하는 시설이다. 지하공동구가 훼손될 경우 국가안보는 물론 사회전반에 미치는 파장이 지대하므로 화재예방 활동 및 진압대 책상 취약점 등을 분석하여 우리 실정에 맞는 방재 대책을 도출하여 공동구의 설계, 제도적인 문제, 방화시설의 문제, 화재확산현상 등을 분석하여 종합적인 화재위험을 분석하여 화재예방활동과 진압대책을 수립하여야 한다. 지하공동구는 밀폐 폐쇄된 공간이므로 산소공급 부족으로 인한 불완전 연소 등으로 농연, 일산화탄소 등 유독성연소생성물의 발생과 열기의 충만 및 시야장해로 진입이 곤란 하는 문제점이 있다. 이러한 현상은 지상화재보다는 지하 화재의 특수성에 비추어 볼 때 화재예방활동은 물론이고 소방전술에서 취약하므로 화재의 효율적인 소방전술이 되기 위해서는 화재의 특이성을 감안하여 유관기관에서는 현장대응 지휘체제를 확립하고, 대응기관에서는 평상시 공동구에 대한 구조파악과 필요한 각종 정보를 수집 기록하고 24시간 관리공조체제 유지 및 대응기관에서 가상종합훈련을 강화하여야하며 근본적으로 공동구내에 설치되어 있는 케이블의 난연화 불연화 및 연소 확대 방지를 위한 대책 등이 필요하다.

용융형 스프링클러 헤드의 응답시간 지수 및 작동시간에 관한 연구 (A Study on Response Time Index and Operating Time for Fusible Link Sprinkler Head)

  • 이병곤;태순호
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.34-44
    • /
    • 1991
  • In this study, the general solution of heat balance equation including conductive heat loss were suggested and were determined the constants with the results of experiment in hot tunnel in order to derive the general equation for the response time and to investigate the response time index which represent the characteristics of response of sprinkler head in actual fires. Two types of test were considered, the plunge test, in which the air temperature is represented by a step function, and the ramp test, in which the air temperature increases at a constant rate. As a result, simple equations were derived, which can be predicted the response time for the ramp type fire with the rate of temperature rise and gas velocity, for the plunge type fire with temperature and gas velocity. Also other useful data, such as the effective temperature, time constant, response time index and conduction parameter were obtained.

  • PDF

Seismic retrofitting by base-isolation of r.c. framed buildings exposed to different fire scenarios

  • Mazza, Fabio;Mazza, Mirko
    • Earthquakes and Structures
    • /
    • 제13권3호
    • /
    • pp.267-277
    • /
    • 2017
  • Base-isolation is now being adopted as a retrofitting strategy to improve seismic behaviour of reinforced concrete (r.c.) framed structures subjected to far-fault earthquakes. However, the increase in deformability of a base-isolated framed building may lead to amplification in the structural response under the long-duration horizontal pulses of high-magnitude near-fault earthquakes, which can become critical once the strength level of a fire-weakened r.c. superstructure is reduced. The aim of the present work is to investigate the nonlinear seismic response of fire-damaged r.c. framed structures retrofitted by base-isolation. For this purpose, a five-storey r.c. framed building primarily designed (as fixed-base) in compliance with a former Italian seismic code for a medium-risk zone, is to be retrofitted by the insertion of elastomeric bearings to meet the requirements of the current Italian code in a high-risk seismic zone. The nonlinear seismic response of the original (fixed-base) and retrofitted (base-isolated) test structures in a no fire situation are compared with those in the event of fire in the superstructure, where parametric temperature-time curves are defined at the first level, the first two and the upper levels. A lumped plasticity model describes the inelastic behaviour of the fire-damaged r.c. frame members, while a nonlinear force-displacement law is adopted for the elastomeric bearings. The average root-mean-square deviation of the observed spectrum from the target design spectrum together with a suitable intensity measure are chosen to select and scale near- and far-fault earthquakes on the basis of the design hypotheses adopted.