• Title/Summary/Keyword: Fire receiver

Search Result 31, Processing Time 0.027 seconds

Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver (재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

A Study on Railway Vehicles Fire Detection using HMI Touch Screen (HMI 터치스크린을 이용한 철도차량용 복합화재수신기 개발 연구)

  • Park, In-Deok;Kim, Chang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.38-43
    • /
    • 2016
  • Recent social needs for promoting traffic safety increased and the demand social security in economic, increasing the demand for environmentally friendly rail transport. In particular, when train express such as to secure reliability KTX(Korea Train eXpress) from potential disaster(fire) in the train operation caused by the train express running has been very important. Railroad fire extinguishing system is operated to fire exploding before reaching the flashing point more important than early to quickly detect because of CAN(Controller Area Network) communication to fire suppression and fire receiver, interface, fire fighting equipment from HMI((Human Machine Interface) and fire high-performance to research and development for intelligent composite fire receiver is required.

Protocol Design for Fire Receiver­based Fire Detection Robots (화재수신기 기반의 화재감시로봇을 위한 프로토콜 설계)

  • Lim, Jong-Cheon;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.452-459
    • /
    • 2018
  • Conventional fire fighting robots are controlled by a remote control to monitor the fire scene or to suppress the fire. However, this method has a problem that it takes a long time to prepare robot and input it to fire place in the golden time after the fire, so that it can not sufficiently serve as a fire fighting robot. Using the autonomous driving fire monitoring robot, when a fire signal is generated, in conjunction with a fire receiver a moving robot takes a video of the fire scene and delivers the image to the fire department, so that the fire fighter can decide if it is real fire or not. Thereby it is possible to prevent a sudden spread of an accident by providing a quick judgment opportunity and at the same time suppressing the fire early. In this paper, we propose an architecture of the autonomous mobile fire monitoring robot and the communication protocol required for the robot to work with the fire receiver. A communication protocol is designed to control multiple fire monitoring robots in real time, and a communication with a fire receiver is designed as a hierarchical network to serve as an interface of an Ethernet network using wireless Wi-Fi. The fire monitoring robot and the wireless communication of the fire receiving period are implemented and the effectiveness of the operation is confirmed through the field test.

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

The Study on the Integrated Emergency Management System using Network GR-type Receiver and Control Desk (네트워크 GR형 수신기와 컨트롤데스크를 이용한 통합방재관리시스템에 대한 연구)

  • Baek, Dong-Hyun;Song, Ho-Bin;Kang, Won-Shun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • The buildings of domestic wear the upper floors and an underground in-depth reconciliation tendency to do and the possibility of fire occurrence at the time of formation accident is coming to be high. Therefore will be scattered to various place and is established and prevention of disaster information of the receiver which will integrate there is a necessity which will manage. In this paper away where each receiver is installed in the fire for the remote monitoring and controld able to connect to the Internet and fiber optic cable that can be networked fire receiver and control desk was constructed. Between each device can be used by the fire, and more depending on the status of monitoring and alarm, control and maintenance can be performed to develop an integrated management system. The system is evaluated by the criteria of the KFI, and for each segment of the signal propagation time to perform experiments confirmed the reliability of the performance.

The Fire Detection Scheme Utilizing Received Signal Variation (수신 신호 변화를 활용한 화재 감지 기법)

  • Ha, Kyunguk;Kim, Dongwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.251-254
    • /
    • 2018
  • Research about IoT system that utilizes variation of wireless received signal according to the changing of the surrounding environment are actively being studied. In this paper, firstly we proved that the received signal strength changes according to the ambient temperature variation. Then, we proposed the fire detection scheme by using received signal strength variation when the signal exchange between fixed transmitter and receiver periodically. The proposed scheme consists of the received signal strength change detection unit and the internal receiver temperature detection unit which prevents misunderstanding the received signal strength variation by the changing of wireless channel environment as outbreak of fire. The proposed scheme has the advantage of being able to support the existing receiver through software upgrade without additional device.

  • PDF

A study on the design of a general-purpose automatic fire detection system based on a private wireless network of the fire fighting communication frequency band (소방통신 주파수 대역 자가 무선망 기반 범용 자동 화재 탐지 시스템 설계를 위한 연구)

  • Kim, Minyoung;Choi, Donggyu;Jang, Jongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.246-248
    • /
    • 2021
  • This paper proposes a new general-purpose automatic fire detection system. And it deals with the contents of related research on how to design and develop for this system. The proposed system automatically notifies the user and the nearby fire department when a fire breaks out in a place where a fire alarm is installed. If this is the case, the nearby fire department can quickly confirm this fact and extinguish the fire at an early stage, thereby reducing human and property damage. The main targets of this system are houses and small buildings. The proposed fire alarm functions as a conventional fire alarm, and if a fire occurs, this fact is immediately transmitted to a nearby receiver through wireless data communication. The receiver in this paper communicates data using Korea's firefighting communication frequency band, and establishes one own network by installing it in various places to quickly receive fire alarm data at any time.

  • PDF

A Design and Development of the Smoke Detection System Using Infra-red Laser for Fire Detection in the Wide Space (광역 화재감지를 위한 적외선 레이저 연기 검출 시스템의 설계 및 구현)

  • Park, Jang-Sik;Song, Jong-Kwan;Yoon, Byung-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.6
    • /
    • pp.917-922
    • /
    • 2013
  • In this paper, we propose a smoke detection system in order to detect a fire in a wide space, such as tunnel, airports using infra-red and visible laser. The proposed smoke detection system is composed of infra-red laser transmitter and receiver, visible laser and Zigbee wireless communication network. A visible laser is used to match transmitter and receiver and Zigbee network is utilized to propagate warnings of fire. If smoke is appeared between transmitter and receiver, received signals are decreased and it can be considered as occurring smoke. As IR laser transmitter and receiver are separated by long distance, it is difficult to match due to large variations caused by small change of direction. In this paper, it is proposed to match effectively using visible laser. When smoke is detected, warning informations are propagated by Zigbee network in the developed smoke detection system.

A Study on Real-time Monitoring System of Indoor Fire Detector using IoT (IoT를 활용한 옥내 화재감지기 실시간 모니터링 시스템에 관한 연구)

  • Lee, Hae-Keon;Kwak, Dong-Kurl;Lee, Bong-Seob
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.267-269
    • /
    • 2018
  • This paper is a study to solve the malfunction of Fire Detection System and to react swiftly in case of fire. if a fire occurs because of malfunction of the fire receiver, it may not be possible to respond appropriately. in order to solve this problem, Fire Detection System using IoT, the manager studied the method of confirming the fire occurrence with mobile phone Application. We propose a wireless Fire Detection System by building a server and a client using a micom and a mobile phone application. This is to reduce the damage caused by the fire.

  • PDF

Design and Verification of Addressable Automatic Fire Detection System for Existing Apartments (기존아파트의 적용성을 고려한 주소형 자동화재탐지설비의 설계 및 검증)

  • An, Hyunsung
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.105-114
    • /
    • 2022
  • Non-fire activated fire alarms caused by such actions as cigarette smoke, cooking, and high humidity are fire safety risk factors. In such instances, it is important to quickly locate and replace the actuated detector. However, it is difficult to locate those detectors because most do not have an address function. While new apartments can incorporate addressable fire alarm detectors, in existing apartments there are limitations in converting over to addressable detectors due to cost and power line issues. This study developed an efficient address function for fire alarms in existing apartments. The newly developed system consists of the existing receiver, and a proposed addressable repeater and detector. Utilizing an experimental setup, the performance of the proposed address monitoring system was confirmed to be stable and compatible with the receiver and existing detectors.