• Title/Summary/Keyword: Fire prediction

Search Result 440, Processing Time 0.032 seconds

Prediction of the Manpower Requirement for Special Fire Inspection (소방특별조사 소요인력 예측)

  • Jeong, Keesin;Kim, Jong-Hoon
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • Manpower will need to be increased to conduct special fire inspections. The aim of this study was to predict the manpower required. According to the estimate, 20,332 inspectors will be needed to conduct special fire inspection on a two-person team basis for a year. If the entire object is to be inspected for five-years, it will be inspected at 20% per year. The currently manpower is not enough to inspect all the objects, which will result in a poor inspection. Therefore, the adoption of a full and partial inspection system will be considered. If 10% full inspection and 10% partial inspection will be conducted, 2,734 inspectors will be needed, whereas if 2% of full inspection and 18% partial inspection are conducted, 1,669 inspectors will be needed.

Estimation of FDS Prediction Performance on the Operation of Water-Mist (미세물분무 작동에 대한 FDS 예측 성능 평가)

  • Ko, Gwon Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4809-4814
    • /
    • 2014
  • The aim of the present study was to estimate the prediction performance of a FDS (Fire Dynamic Simulator) to simulate the fire behaviors and suppression characteristics by operating a water-mist. Rosin-Rammler/log-normal distribution function was used to determine the initial droplet distribution of water-mist and the effects of its model constant were considered. In addition, the simulation models were validated by a comparison of the predicted fire suppression characteristics with water-mist injection pressures to the previous experiments, and the thermal flow behaviors and gaseous concentration variations were analyzed. The results showed that water-mists with the same mean diameter were affected by the characteristics of the droplet size distribution, which have different size and velocity distributions at the downstream location. The fire simulations conducted in this study determine the initial droplet size distribution tuned to the base of the spray characteristics measured by previous experiments. The simulation results showed good agreement with the previous measurements for temperature variations and fire suppression characteristics. In addition, it was confirmed that the FDS simulation with a water-mist operation supplies useful details on estimations of the thermal flow fields and gaseous concentration under water mist operation conditions.

PREDICTION OF FIRE EXTINGUISH SYSTEM PERFORMANCE BY NUMERICAL METHOD (항공기 엔진베이 내 소화장치 성능예측을 위한 전산해석방법 연구)

  • Shin, H.B.;Seo, Seok-Ju;Jeong, Ju-Hyeon;Yu, Jin-Bok
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.426-430
    • /
    • 2010
  • There is fire dangers inside engine bay where fuel of oil leakge can be ignited by hot engine surfaces. So, Fire suppressor is needed to extinguish the flames. The current FAA requirement is that the concentration level should be greater than 6% by volume throughtout the protected zone for longer than a half second simultaneously. To Satisfy the FAA requirement, The Fire extinguish system should quickly delivery the fire extinguish agents and Fire extinguish system should be designed effectively. This study is to develop and simulate the injection of fire extinguish agents into the engine-bay. Transient simulations were performed and predicted the concentration of fire extinguish agents at the certain locatioin in the engine-bay.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Traditional Market Area (전통시장지역의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.46-47
    • /
    • 2017
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the traditional market area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Building Congested Area (건축물 밀집지구의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Yoon, Ung-Gi;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.226-227
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Wooden Building Congested Area (목조건물 밀집 지역의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Kim, Bong-Chan;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.87-88
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the wooden building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Estimation of Required Fire Resistance Time by Use of Building (건축물의 용도별 필요내화시간 산정에 관한 연구)

  • Kim, Yun-Seong;Han, Ji-Woo;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.115-116
    • /
    • 2020
  • Due to the nature of modern society, buildings are becoming larger and more complex. As a result, the design conditions of the building are changing. However, despite the complexities of buildings, the fire resistance performance is still equalized to one hour without considering fire engineering analysis in Korea, so there is a risk according to actual fire design conditions. Therefore, the purpose of this study is to calculate the required fire resistance time for actual fire through fire mechanics analysis and case study.

  • PDF

Pohang City Fire Vulnerable Area Prediction and Fire Damage Rating Measurement by Administrative District (포항시 화재 취약지역 예측 및 이에 따른 행정구역별 화재 피해 등급 측정)

  • Lim, Jung-Hoon;Kim, Heon-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.4
    • /
    • pp.166-176
    • /
    • 2021
  • Due to urbanization and industrialization, the importance of large-scale fire prevention, management and measures is increasing day by day. However, the fire site arrival rate in Golden Time, which is a factor that can minimize large-scale fire damage, of Pohang, a large city with a population of over 500,000, is relatively low. So additional fire fighting power deployment and infrastructure investment are required. However, as budget and manpower are limited, it is necessary to selectively deploy fire fighting power and invest in infrastructure. Therefore, this study attempted to present a fire damage rating that can compare the level of fire damage, which is an index that can help selectively provide fire fighting services in Pohang and make related decisions. For the index, the OD cost matrix was used to predict fire vulnerable areas with a high probability of increasing the fire scale in the event of a fire. Also fire damage was measured by predicting the level of fire damage in the event of a fire according to population, building density, and access of fire trucks. It is expected that the fire damage rating will be able to help in various decisions related to fire fighting service deployment and services not only in Pohang city, but also in other regions.

Evaluation of the Prediction Performance of FDS Combustion Models for the CO Concentration of Gas Fires in a Compartment (구획실 내 가스연료 화재의 CO 농도에 대한 FDS 연소모델의 예측성능 평가)

  • Baek, Bitna;Oh, Chang Bo;Hwang, Chel-Hong;Yun, Hong-Seok
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The prediction performance of combustion models in the Fire Dynamics Simulator (FDS) were evaluated by comparing with experiment for compartment propane gas fires. The mixture fraction model in the FDS v5.5.3 and Eddy Dissipation Concept (EDC) model in the FDS v6.6.3 were adopted in the simulations. Four chemical reaction mechanisms, such as 1-step Mixing Controlled, 2-step Mixing Controlled, 3-step Mixing Controlled and 3-step Mixed (Mixing Controlled + finite chemical reactions) reactions, were implemented in the EDC model. The simulation results with each combustion model showed similar level for the temperature inside the compartment. The prediction performance of FDS with each combustion model showed significant differences for the CO concentration while no distinguished differences were identified for the $O_2$ and $CO_2$ concentrations. The EDC 3-step Mixing Controlled largely over-predicted the CO concentration obtained by experiment and the mixture fraction model under-predicted the experiment slightly. The EDC 3-step Mixed showed the best prediction performance for the CO concentration and the EDC 2-step Mixing Controlled also predicted the CO concentration reasonably. The EDC 1-step Mixing Controlled significantly under-predict the experimental CO concentration when the previously suggested CO yield was adopted. The FDS simulation with the EDC 1-step Mixing Controlled showed difficulties in predicting the $CO_2$ concentration when the CO yield was modified to predict the CO concentration reasonably.

Calculation of Fire-resisting Time and Extraction of Simple Transplants in the Event of a Building Fire (건축물 화재시 필요내화 시간 산정 및 간이식 도출)

  • Kim, Yun-Seong;Han, Ji-Woo;kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.59-60
    • /
    • 2020
  • Large fires continue to spread throughout the building, including the fire in Uijeongbu in 2015, the fire in Jecheon in 2017, and the fire in Miryang in 2018. According to the above fire case investigation, major problems were the fire resistance performance of compartment members such as fire doors, the fire spread due to damage to exterior wall openings, and smoke spread through vertical openings. However, in South Korea, only specification design is implemented for buildings that are not subject to performance design. In addition, the analysis of the fire resistance performance standards of building members in the specification design showed that fire doors were not specified in detail for 60 minutes of insulation performance and 60 minutes of fire resistance performance of E/V doors, limiting the prevention of fire spread. Therefore, the purpose of this research is to prepare measures to prevent the spread of fire by presenting simple transplants for calculating the required fire time according to the architectural design conditions for the performance design of the components of the fire room according to the purpose of use of the front of the building.

  • PDF