• Title/Summary/Keyword: Fire possibility

Search Result 358, Processing Time 0.026 seconds

Prediction for Possibility of the Electric Fire by Tracking Breakdown (트래킹에 의한 전기화재 가능성 예측)

  • Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • Tracking, which is one of main reasons of the electric fire, progresses gradually, and therefore, the possibility of fire caused by tracking can be predicted by analyzing the stage of its progress. This paper is conducted in order to predict possibility of the electric fire caused by the tracking in the simulated electric equipment with load. Non-inductive resistance is used as the load. The tracking is happened in a Polyvinyl-chloride-sheathed flat cord, which is a part of the simulated electric equipment by means of dropping of electrolyte droplet. In order to predict the possibility of electric fire caused by tracking, we detect the whole current waveforms of the simulated electric equipment. The time-energy analysis and probability distribution are used for analysis of the tracking progress from the whole current waveforms. In accordance with the results is used for input date of Neural networks, the neural networks can be predict possibility of the electric fire in the electric equipment by 4 stages.

A Study on the Possibility of Expanding the Use of Green Remodeling for Fire Stations (소방서를 대상으로 한 그린리모델링 용도 확대 가능성 분석에 관한 연구)

  • Sangheon Jeong;Jinhwan Oh;Sangmu Bae;Yujin Nam
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.1
    • /
    • pp.8-15
    • /
    • 2024
  • This study aims to investigate the possibility of expanding the support program for green remodeling of fire stations and analyze the standard design guidelines. Green remodeling is essential for reducing greenhouse gas emissions and promoting green buildings, but currently, it is only conducted for buildings with limited purposes. In this study, we conduct green remodeling for fire stations with severe aging to demonstrate energy performance improvement and investigate the potential for expanding the support program to other types of aging buildings. The research methodology includes analysis of previous studies, preliminary investigation and alternative setting, energy analysis, calculation of construction costs, evaluation of the possibility of introducing support programs, and examine of the fire station standard design guidelines. The research results confirm that green remodeling can reduce energy consumption in fire stations and present the possibility of including fire stations as targets in the support program for green remodeling of public buildings.

Fire Risk Analysis through Airfryer's Fire Cases and Reproduction Experiments (에어프라이어의 화재사례와 재현실험을 통한 화재위험성 분석)

  • Lee, Jung-Il;Jo, Myeng-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.39-46
    • /
    • 2020
  • This paper recognizes the risk of ignition of air fryer (machine that can cook fried dishes with hot air without oil) that is far exceeding the sales rate of microwave ovens, which is necessary to modern household kitchen, and identifies fire risk through the operation principle of the process of heat transfer, and the main structure of the machine. The fire test that we conducted is to observe the risk of ignition of the machine due to the damage to the safety system and the possibility of igniting oil paper along with food, to experiment with the possibility of ignition due to blockage of the exhaust due to obstacles, and accumulation of oil stains on the hot wire, and to present the method of fire control and devise countermeasures.

A Study on the Risk of Fire Caused by Sparks during Grinding Operation (그라인딩 작업 중 발생하는 불티의 화재 예방에 관한 연구)

  • Seong-En Kim;Geun-Chul Lee;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.751-756
    • /
    • 2023
  • In this study, We investigated a fire case and performed an experiment to prevent fire from sparks that is generated during grinding operation. Before conduct the test, confirmed that the generating mechanism of fire-flakes in working grinder and the fire experiment was conducted using commonly tools, flammable materials in industrial field. in result, It could be measured scattering distance, temperature, ignition possibility by type of combustible materials. Based on the results of this study, We are expected to be used as basic data for fire prevention in grinding Industry.

A Study on the Spontaneous Ignition Possibility of Shredded Waste Thermoplastic Elastomer (폐 열가소성 플라스틱 탄성체 분쇄물의 자연발화가능성에 관한 연구)

  • Park, Young Ju;Lee, Hae Pyeong;Goh, Kyoung Chun;Eom, Young Sup
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • In this study, we considered the ignition possibility for the shredded thermoplastic elastomer at the fire ground loaded the waste TPE. The average moisture content of the TPE sample was almost 0.33 wt.% at $110^{\circ}C$ and the range of ignition point was $461.9{\sim}491.9^{\circ}C$ approximately. In addition, we analyzed the change of weight and calorie the TPE sample according to temperature variations using the TG-DTA analyzer. As a result, the weight loss occurred twice in $250{\sim}420^{\circ}C$ and $420{\sim}473^{\circ}C$, and we found the second weight loss temperature range was the ignition point of TPE. Also, we conducted the spontaneous ignition tests of TPE for the wet and dry samples and we confirmed that the possibility of spontaneous ignition of TPE was very low. The elapsed time and humidity had little influence on the spontaneous ignition of TPE in this experimental conditions. In conclusion, the spontaneous of the shredded waste TPE in this study.

Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact (전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석)

  • Kim, Doo Hyun;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

Construction of Diagnosis System for Electric-fire Causes using Fuzzy Possibility Measure (퍼지가능성 척도를 이용한 전기화재 원인진단 시스템의 구축)

  • 김두현;김상철
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.4
    • /
    • pp.105-114
    • /
    • 1992
  • This paper presents an study on the knowledge based system for diagnosing the fire causes using the Fuzzy Possibility Measure( FPM ) about the electric-fire ignition. The Ignition values needed for causes diagnosis is computed as FPM for electric-fire ignition based on the internal scale technique that assigns numerically the characteristic difference of facts to the-tin-ear scale. For the convinience of inference, ignition sources are classified into seven types : short, ground fault, leakge of electricity, overcurrent, cord junction overheating, bad Insulation and spark. The system for causes diagnosis of electric-fire is composed of Knowledge Acquisition System, Inference Engine and Man-Machine Interface, The diagnosis system is wrritten in an artificial intelligence langusge “PROLOG” which uses depth-first search and backward chaining schemes in reasoning process.

  • PDF

A Study on Fire Analysis According to Temperature Characteristics of an Incandescent Electric Lamp at 220V/100W (220V/100W 백열전구의 온도특성에 따른 화재분석에 관한 연구)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Young-Seok;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, we are studied on the temperature characteristics and fire progress of an incandescent electric lamp at 220V/100W. In the case of stationary state, the ignition possibility of the incandescent electric lamp due to the heat generation was low because the temperature was measured at $161.9^{\circ}C$ the temperature was increased at $538.1^{\circ}C$ in the airtight chamber, but it does not generated the fire because the oxygen was not exist in the airtight chamber. When the lamp is broken, the filament of lamp was melted in the air. The gas of lamp interior spurted to the weakest part by external flame. Thus, the incandescent electric lamp is high possibility of fire when oxygens from airtight space. Also, it is known that the possibility of ignition is very high if combustion materials(sawdust) exists on surrounding. These experimental results will be utilized for the data in the investigation electrical fire cause.