The Analysis on Forest Fire Occurrence Characteristics by Regional Area in Korea from 1990 to 2014 Year

  • Jeon, Bo Ram;Chae, Hee Mun
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.2
    • /
    • pp.149-157
    • /
    • 2016
  • Understanding regional characteristics in forest fire occurrence is important to establish effective forest fire prevention policy in Korea. This study analyzed the characteristics of forest fires occurred in 16 administrative districts for recent 25 years (1990~2014) to examine regional characteristics in forest fire occurrence. Forest fire occurrence reflects regional characteristics depending on climatic factors as well as region's society-cultural factors. Results showed that the first cause of forest fire occurrence was carelessness by human activities throughout all administrative districts, however, the second cause depends on regional characteristics. As the results of forest fire occurrence period analyzed for 10 days, the most forest fires occurred in the southern region during January to March, while forest fires in the northern region occurred mostly during March to April. We classified forest fire occurrence patterns into three types (centralized: Gyeonggi-do, dispersal: Busan, horizontally distributed: Gyeongsangnam-do) by multi-temporal analysis for forest fire occurrence period.

Estiamtion of Time Series Model on Forest Fire Occurrences and Burned Area from 1970 to 2005 (1970-2005년 동안의 산불 발생건수 및 연소면적에 대한 시계열모형 추정)

  • Lee, Byungdoo;Chung, Joosang
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.6
    • /
    • pp.643-648
    • /
    • 2006
  • It is important to understand the patterns of forest fire in terms of effective prevention and suppression activities. In this study, the monthly forest fire occurrences and their burned areas were investigated to enhance the understanding of the patterns of forest fire in Korea. The statistics of forest fires in Korea, 1970 through 2005, built by Korea Forest Service was analyzed by using time series analysis technique to fit ARIMA models proposed by Box-Jenkins. The monthly differences in forest fire characteristics were clearly distinguished, with 59% of total forest fire occurrences and 72% of total burned area being in March and April. ARIMA(1, 0, 1) was the best fitted model to both the fire accurrences and the burned area time series. The fire time series have a strong relation to the fire occurrences and the burned area of 1 month and 12 months before.

A Phenomenological Studies on Ignition Characteristics of Wires by Local Impact, Over Loading and Overcurrent (국부적 충격, 과부하 및 과전류에 의한 전선의 발화특성에 관한 현상학적 연구)

  • Lee, Jeong-Jin;Lee, Chang-Woo;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.53-60
    • /
    • 2010
  • When a fire breaks out, it is difficult to find out the causes of the fire, because combustible things around fire scene are usually burnt away. Among many causes of fires are electronic wires, this thesis deal with the destroyed sheath of electronic wires caused by fire. It was studied with the use of measurement devices focusing on the distinctions of wires and conductors. This study especially emphasized the process of deterioration, burning pattern, and composition of electronic wire conductor. It also has a phenomenological approach to the distinctive cause of fire by some partial force. The fire prevention methods have been suggested through the analysing results of fire patterns. This study is expected to be a useful material for analyzing various electrical fires.

Forest Fire Ignition Patterns Caused by Farming Activities (영농활동으로 인한 산불발생 특성)

  • Koo, Kyo-Sang;Lee, Byung-Doo;Lee, Myung-Bo;Lee, Si-Young;Kim, Jeong-Hun;Park, Houng-Sek;ParK, Geon-Young
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.103-110
    • /
    • 2010
  • Farming activity was the second cause of forest fire following the carelessness. In this study, 74 forest fires caused by farming activity and waste burning in 2009 was investigated for analyzing ignition patterns. The main cause to bring about forest fire was the farming waste burning as 25 cases, burning of farming waste matter after product and household waste burning were the second causes as 19 cases. Landcovers which transfer flame from ignition point to forest were fallow field graveyard, field fruit farm, field levee fallow field. The average distance between ignition point and forest sleeve was 19 m, and the maximum distance was 130 m. The probability of forest fire ignition was high in the 100 m buffer zone from the forest sleeve that is the prohibition rule of fire use for forest fire prevention at the forest fire season.

An Identification of Sungnyemun Fire as a Case Study (숭례문 화재감식 사례 연구)

  • Choi, S.B.;Lee, S.J.;Lee, S.H.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.74-82
    • /
    • 2008
  • The fire of Sungnyemun, National Treasure of No.1, gave to the Korean people and fire investigators big pains. The aim of this study are the identification of combustion traces and fire patterns of wooden building fire, burned with an accelerator, after spraying flammable materials on the wooden floor through the field study observation. Also, in the case of the similar fire, these results will be as good references to fire investigators for accurate investigations.

  • PDF

An Analysis of Operation Patterns based upon Actual Measurements of Pressurization through Open Door in Smoke Control Zone (제연구역 출입문의 차압 측정에 따른 작동패턴 해석)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.245-247
    • /
    • 2011
  • 본 연구에서는 제연구역과 옥내와의 차압 및 출입문의 폐쇄력 측정을 통해 제연구역 출입문의 작동패턴을 해석하였다. 이를 통해 제연구역 출입문의 폐쇄력 측정시 정확한 측정을 위해 출입문을 완전히 폐쇄한 상태에서 측정을 하여야 하며, 문의 크기에 비례하여 증가하는 폐쇄력을 고려한 제연설비 설계에 대한 근거를 제시하였다.

  • PDF

The Fire Dispersive Patterns of the Power Cord Sets for Low Voltage Appliances in Wall-modeling (벽면 모델링을 이용한 저압용 일체형 코드의 화재확산 패턴)

  • Shong, Kil-Mok;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo;Kim, Young-Seok;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.330-334
    • /
    • 2004
  • In this paper, we studied on the fire dispersive patterns and the fire progress at the power cord sets for low voltage appliances in the wall-model. For the experiment, we manufactured a wall-model and applied the external flame at the power cord sets. From the results, short-circuit of the power cord sets was haunted by the external flame it was disconnected with the flashing and the scattering. The fire progress on the polyvinyl chloride insulated flexibel cords is not observed because the ignition energy decreases. In case of rubber insulated flexible cords, however, the fire was progressed continuously. Molten marks were formed at a two electric wire by continuous electric discharge in power source part. A large molten mark was formed in load part. And the columnar structure and voids were observed in molten wire.

  • PDF

A Study on the Current State and Improvement of Operation of Fire Investigation Teams (화재조사 실태 분석과 개선방안에 관한 연구)

  • Lee, Tae-Geun;Chae, Jong-Min
    • Journal of forensic and investigative science
    • /
    • v.1 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • The purposes of fire investigation are to identify and analyze the causes of fire and, using the results in promoting fire fighting policies, ultimately to prevent fires caused by similar causes and to protect people's life and properties from fire. However, although the patterns of fire are getting more diverse and complicated with the rapid development of industry, complicated with the rapid development of industry, fire fighting organizations are continuing traditional superficial fire investigation without operating a fire investigation department for the reason of insufficient manpower, equipment and budget, losing public confidence. Thus, the present study purposed to propose plans to improve the technicality of fire investigation and win public confidence in fire investigation. First, the technicality of fire investigation should be improved by operating a department and personnel exclusively for fire investigation. Second, fire investigation should be more scientific and precise using high tech fire investigation equipment. Lastly, responsible fire fighting administration should be realized through statistical analysis of the causes of fire and computerization. The results of this study are expected to contribute to the safety and security of our society.

  • PDF