• 제목/요약/키워드: Fire pattern

검색결과 335건 처리시간 0.026초

웨어러블 기기의 배터리화재사례와 실험을 통한 화재위험성 분석 (Analysis of Fire Risk through Battery Fire Cases and Experiments of Wearable Devices)

  • 이정일
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.47-55
    • /
    • 2020
  • This study analyzed ignition probability about Lithium-polymer batteries of what variously were being produced wearable devices recently. The study analyzed ignition probability by PCM(Protection Circuit Module) operating state and overcharged, over-discharged, exposed to high temperatures of Lithium polymer batteries, analyzing wearable devices on the market. Then it classified experimental results to implement analysis comparison about weight, X-ray imaging, battery decomposition. With these experiments, the study analyzed combustion-possibility and fire patterns. These statistics will be used to measure and verify the cause of a fire when identify wearable devices using Lithium-polymer batteries.

전원주택의 벽난로와 관련된 화재사례의 분석 (A Case Study on Fire Investigation for a Wood-Burning Stove in an Idyllic House)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.119-128
    • /
    • 2015
  • 이 논문에서는 신축 후 약 2년이 경과한 전원주택에서 벽난로 가동 중에 벽난로로 인한 화재가 발생하여 전소된 사례에 대해 법원을 통해 소방서, 경찰서, 화재보험관련 조사기관, 주택을 시공한 건설회사와 벽난로를 시공한 벽난로제조업체로부터 제공받은 자료들을 분석하여 벽난로 옆 벽체의 목재기둥에 남아 있는 저온장기발화의 화재패턴을 근거로 벽난로 옆 벽체의 목재기둥에 벽난로 화실(火室)의 열이 전도되어 화재가 발생하였음을 입증하였다. 그리고 벽난로 옆의 목재기둥이 저온장기발화를 한 이유는 굴뚝에 환기를 위한 공기창을 설치하지 않았기 때문임을 화재시뮬레이션을 통해 입증하였다.

산불진화용 안전복 패턴 개발을 위한 연구 (A Study on the Pattern Development for Forest Fire Safety Clothing)

  • 최미성
    • 한국의류산업학회지
    • /
    • 제13권4호
    • /
    • pp.624-634
    • /
    • 2011
  • The purpose of this study is to develop the pattern of safety clothes used at flat or mountainous areas and to identify the pattern of safety clothes by conducting experimental evaluation of virtual wear. Three subjects were selected, based on fire fighters' physical constitution. A prototype design for safety clothing was determined after in-depth interviewing of professionals and surveying of Forest service staff and related agency. Wearing test should be carried out in the order of pattern making, virtual and real wearing evaluation. For data analysis, technical statistical values should be obtained by using body measurements of subject, frequency analysis and T-test. The jacket is designed to have a front extension and the entire length of clothing enough for wearer to put on it over ordinary shirts or sweater. The collar of jacket is of round type. Cyber reality enables to identify the movement and activity of virtual fitting model and to find out errors or problems in safety clothing prior to on-the-spot wear test, thus raising the precision level of pattern. There was significant difference between real and virtual fit preference. The results show that the virtual try-on system need the development of a specific style.

유리 파단면의 화재감식에 관한 실험적 연구 (An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass)

  • 문용수;공하성
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

외부화염에 의한 드라이비트의 소손패턴 연구 (A Study on the Damaged Pattern of Dryvit by External Flame)

  • 박영주;홍이표;이해평
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.40-47
    • /
    • 2015
  • In this study, temperature characteristics and fire damage form were analyzed to investigate flame spreading form and fire probability from ignition sources subject to drivit component materials which is finishing material in architecture. Ignition sources were limited to a gas torch and exterior panel board fire, and the size of the sample was manufacture in 30 cm length ${\times}$ 50 cm height ${\times}$ 5cm thickness size. Marble (inner wall) + 3 mm drivit (outer wall), marble (inner wall) + 4 mm plaster stone (outer wall), sandwich panel + 3 mm driver bit (outer wall), sandwich panel + 3 mm driver bit + insulation (outer wall), and gypsum board (inner wall) + 3 mm drivit (outer wall) were prepared for the sample. As result of the research for temperature characteristics, large temperature difference by each material was shown in $218^{\circ}C{\sim}995^{\circ}C$ at 30 seconds and $501^{\circ}C{\sim}1078^{\circ}C$ at 300 seconds. Especially when the inner wall was a plaster board, lowest temperature of $501^{\circ}C$ was shown at 300 seconds and marble inner wall showed the following lowest temperature of $900^{\circ}C$. Temperature rising over $1000^{\circ}C$ was shown in other materials. Regarding fire damage form, drivit or gypsum board outer wall parts exposed to fire showed combustion and carbonization to show calcination(breaking phenomenon) and influence of heat exposure was higher as calcination became more severe.

니들 플레임에 의한 바닥재의 수직 연소 및 탄화 패턴의 해석에 관한 연구 (Analysis of Vertical Combustion and Carbonization Patterns of Floor Materials When Using a Needle Flame)

  • 박민수;최충석
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.101-106
    • /
    • 2020
  • 자체 제작된 니들 플레임을 이용하여 바닥재를 수직 연소시켰을 때의 화염의 성장 특성 및 탄화 패턴을 해석하였다. PVC 장판은 난연성이 있는 것으로 확인되었고, 직사 화염을 받은 곳은 안쪽으로 수축되는 패턴을 나타냈다. 수직 연소가 진행되면 하부에 망울 형태의 고형화가 발생하며, 그을음은 상부로 성장하는 패턴이 형성된다. 강화마루는 난연성이 없는 것으로 확인되었으며, 상부 표면인 라미네이트층의 소실과 불규칙적인 박리가 형성되는 것을 알 수 있다. 좌측면과 우측면의 탄화의 범위는 대칭적 구조를 나타내는 것으로 해석된다. 강화마루와 마찬가지로 카펫은 수직 연소 실험에서 난연성이 없는 것이 확인되었다. 카펫에 축열이 형성되면 화염은 상승기류를 형성하고, 주변에 가연성 물질이 있을 때 화염의 확산은 더욱 촉진하는 것을 알 수 있었다. 직사화염을 받은 카펫 표면의 탄화 패턴은 표면이 용융되어 흘러내렸을 뿐만 아니라 작은 구멍이 다수 발생되는 것을 알 수 있다.

인위적으로 착화시킨 정수기의 연소 확산 패턴에 관한 연구 (Study of Burning Spread Pattern of Water Purifier that is Ignited Artificially)

  • 최충석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.167-169
    • /
    • 2012
  • 본 연구는 정수기 화재의 원인 판정을 위한 지식기반을 구축하기 위해서 인위적 착화가 발생했을 때의 연소 확산 패턴을 해석하였다. 실험이 재현되는 동안 외부에서 인위적인 에너지의 공급은 없었으며, 정수기는 정상 작동 상태를 유지시켰다. 인위적 화염으로 착화되어 50[sec] 경과하였을 때까지 불꽃은 외부에서 관측되지 않았다. 그러나 120[sec] 정도 경과되었을 때 일순간 화염은 확산되기 시작하였으며, 부분적인 소락이 발생되는 것이 관측된다. 화염이 180[sec] 동안 진행되었을 때 강제로 진압된 후 연소패턴 분석에서 최초의 착화점을 기준으로 정확한 브이패턴(V-pattern)이 형성되었으며, 외부에서 화염이 공격되었을 때와 확연한 차이가 있음을 알 수 있다. 또한 정수기 후면에 설치된 방열판의 열화 특성 분석에서 화열의 공격방향 판정이 가능한 것을 알 수 있었다.

  • PDF

전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정 (Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill)

  • 김형균;정기봉;고석만;오무송;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF

1991년부터 2007년까지 산불의 공간적 특성 (Spatial Patterns of Forest Fires between 1991 and 2007)

  • 이병두;이명보
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.15-20
    • /
    • 2009
  • 산불을 효율적으로 관리하기 위해서는 지역별 산불 행동 특성에 대한 이해가 요구된다. 본 논문에서는 전국 시 군 구 단위고 산불통계 자료를 이용하여 발생 및 확산 특성을 분석하였다. 이를 위해 1991년 부터 2007년까지 17년간 발생건수, 연소면적, 확산속도, 건당 면적 자료를 이용하여 산불 특성에 따라 군집을 분류하고 GIS를 이용하여 공간적 분포 특성을 분석하였다 분석결과, 산불의 공간적 특성 변이가 뚜렷하게 관찰되었고, 전국 시 군 구는 산불위험성에 따라 5개의 군집으로 분류할 수 있었다. 대도시와 인근 지역은 산불위험이 낮은 군집으로 분류되었으나, 강원도 영동지방 4개 시 군은 가장 위험한 군집으로 분류되었다. 그 뒤를 이어 남, 서해안에 인접한 시 군 구의 산불위험성이 높았다.

산불진화 헬기의 물 살포유형 분석에 관한 연구 (Analysis of the Helicopter Fire Attack Pattern on Forest Fire Behavior)

  • 이시영;배택훈
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.96-100
    • /
    • 2009
  • 우리나라는 최근 숲이 우거져 있어 산불이 발생하면 대형화 위험성이 증대하고, 인력접근이 제한되어 항공기에 의한 진화율이 90% 이상이 된다. 그러므로 항공기 특히 헬기의 산불진화 활용성은 점차 증대 될 전망이다. 아울러 산불진화의 전 과정에 있어서 헬기 물 살포 기술은 안전한 헬기운항과 효율적인 산불진화의 성공요인으로서 특히, 표준화된 물 살포 기술은 매우 필요하다. 그러나 아직 헬기 물 살포 기술이 표준화 되지 않으므로 인하여 산불진화의 효율성과 안전성이 떨어지고 있다. 따라서 본 연구에서는 산불 현장 공중진화 경험을 바탕으로 11개의 헬기 물 살포 유형을 제안하였다.