• Title/Summary/Keyword: Fire pattern

Search Result 335, Processing Time 0.03 seconds

Study of the Characteristics and Crystal Growth of a shorted Wire by Overcurrent (과전류에 의해 단락된 전선의 결정성장 특성에 관한 연구)

  • Park, Jin-Young;Bang, Sun-Bae;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • If an overcurrent exceeding the rated value is applied to an electric wire, the temperature of the electric wire increases, and the electric wire covering deteriorates to cause a short circuit. The upper limit temperature of the wire varies according to the magnitude of the overcurrent. When a short circuit occurs at each upper temperature limit, a cooling speed difference occurs during the solidification process due to the temperature difference between the short circuit temperature and the wire surface temperature. At this time, the pattern characteristics of the dendritic structure formed on the molten cross section are different. In this study, the upper temperature limit, which varied according to the overcurrent magnitude, was measured. At the time a short circuit occurred, the second branch spacing (dendrite Arm Spacing : DAS) of the dendrite was analyzed and the numerical value was quantified. The experimental results showed that the upper temperature limit increases with the magnitude of the overcurrent, and that the second branch spacing increases with increasing wire temperature.

A Study on the Analysis of Damage Cause for MOF Installed in 22.9 kV Power Receiving System (22.9 kV 수전설비 시스템에 설치된 계기용변성기의 소손원인 판정에 관한 연구)

  • Kim Hyang-Kon;Shong Kil-Mok;Kim Dong-Ook;Choi Chung-Seog
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.93-98
    • /
    • 2005
  • The purpose of this paper is to judge the damage cause of instrument transformer(MOF; Metering Out Fit) installed in 22.9kV power receiving system. In the three-dimensional analysis of the restored MOF, the damage pattern progressed from inside to outside, there was no damaged part in the upside. The resistance of the carbonized middle part is roughly $100\kappa\Omega$ and the exothermic temperature at inside is presumed as about $300\~800^{\circ}C$ in the result of metallurgical structure analysis. The structure and the composition rate on metal surface by SEM is similar. In the result of FT-IR analysis, we can observe the absorbtion peak at $1500cm^{-1}\;and\;1730 cm^{-1}$ is small. The high exothermic peak showed at the center part of the coil in the result of DTA.

Detection of Indication of Electric Accident in Simulated Electric Equipments Using Standard Deviation and Probability Distribution (표준편차와 확률분포를 이용한 모의전기설비에서 사고징후 검출)

  • Jee, Seung-Wook;Ok, Kyung-Gea;Kim, Shi-Kuk;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.11-16
    • /
    • 2009
  • This paper describes a detecting method for indication of an electric accident in electric equipments. For that, loads of electric equipment is consisted of incandescent lamps. And the electric accident is simulated a tracking test apparatus according to KS C IEC (Korea Standard C International Electrostatic Commission) 60112 at some part of the simulation of the electric equipment. Simulated electric accident is occurred from static states through discharge in progress, carbon formation to tracking breakdown. The total current of electric equipments is measured and analyzed for detecting of indication of the electric accident using a current monitor. For the result, as an electric accident processed, as a current pulse is bigger and a ratio of appearance also increases at certain part of current waveforms. And standard deviation and probability distribution for certain part of current waveforms show remarkably different pattern in each step of electric accident which is irrespective of amount of load.

Study on the Analysis of Damage Patterns of Cellular Phone Batteries According to Energy Sources (에너지원에 따른 이동전화기 배터리의 소손패턴 해석에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.21-26
    • /
    • 2011
  • The purpose of this paper is to present the damage patterns of cellular phone (SCH_W830) batteries according to energy sources and have them utilized as data for the settlement of disputes between manufactures and consumers. The reliability was secured by maintaining the ambient temperature and humidity at $22{\pm}2^{\circ}C$ and 40~60 %, respectively. The voltage of the battery used for the tests was measured to be 4.18V between positive pole (+) and negative pole (-)(1), and 4.19 V between positive pole (+) and negative pole (-)(2). This study applied the Korean Industrial Standard (KS) to the flammability test of cellular phones due to a general flame applied to them and found that no damage occurred to the built-in battery even though the flame was applied to the cases of cellular phones for 30 seconds. From the results of immersing the cellular phones in the saline solution (NaCl, 0.9 %) for 180 seconds, it was found that there was a trace of carbonization and melting due to the heat caused by leaking current. It can be seen that when the cellular phones were heated for 70 seconds using a microwave oven (MWO), the areas containing the metal holder, recharging connector, antenna, etc., were melted and discolored and that other areas showed no particular problems. That is, while the external carbonization of cellular phones, built-in metals and dielectric materials, and damage and deformation of the battery terminal block, etc., occurred differently depending on the types of energy sources, the voltage showed comparatively constant characteristics. Therefore, it is thought to be possible to attribute the cause of damage to the battery by performing analysis taking into consideration comprehensively the characteristics of the flame spread pattern as well as the melting and deformation of metals.

A Study on the Characteristics of Organic Insulating Materials Carbonized by a Leakage Current (누설전류에 의하여 탄화된 유기절연재료의 특성에 대한연구)

  • Park, Sang-Taek;Roh, Young-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.161-167
    • /
    • 2009
  • Organic insulating materials which are utilized as insulating materials for the low voltage show unique carbonization characteristics when they are carbonized by a leakage current. Therefore the use of the carbonization characteristics makes it possible to examine the electrical fire which is caused by a leakage current flowing on the surface of the organic insulating material. In order to understand such carbonization characteristics, in this paper, experiments have been done to carbonize typical organic insulating materials such as phenol resin, PVC, and acrylic resin, and the carbonization patterns and the IR absorption spectrum of specimens have been analyzed. According to the analysis of the carbonization patterns, the phenol resin shows the so-called 'spider-leg' carbonization pattern due to a thermosetting property. In contrast to the phenol resin, the thermoplastic property makes it difficult to observe a clear carbonization pattern to verify carbonizing causes on the surfaces of PVC and acrylic resins. In this case, the IR absorption spectrum can be analyzed to examine the specimen carbonized by a leakage current. The analysis result shows that absorption peaks appear at the wave numbers of $3,400[cm^{-1}]$ and $1,618[cm^{-1}]$, which can be an important factor to verify the carbonizing causes.

On the vibration influence to the running power plant facilities when the foundation excavated of the cautious blasting works (삼천포화력발전소 3, 4호기 증설에 따르는 정밀발파작업으로 인한 인접가동발전기 및 구조물에 미치는 진동영향조사)

  • Huh, Ginn
    • Journal of the Korean Professional Engineers Association
    • /
    • v.24 no.6
    • /
    • pp.97-105
    • /
    • 1991
  • The cautious blasting works had been used with emulsion explosion electric M/S delay caps. Drill depth was from 3m to 6m with Crawler Drill ø70mm on the calcalious sand stone (soft-moderate-semi hard Rock). The total numbers of fire blast were 88 round. Scale distance were induces 15.52-60.32. It was applied to propagation Law in blasting vibration as follows. Propagation Law in Blasting Vibration (Equation omitted) where V : Peak partical velocity(cm/sec) D : Distance between explosion and recording sites(m) W : Maximum Charge per delay-period of eighit milliseconds o. more(kg) K : Ground transmission constant, empirically determind on the Rocks, Explosive and drilling pattern ets. b : Charge exponents n : Reduced exponents Where the quantity D / W$^n$ is known as the Scale distance. Above equation is worked by the U.S Bureau of Mines to determine peak particle velocity. The propagation Law can be catagrorized in three graups. Cubic root Scaling charge per delay Square root Scaling of charge per delay Site-specific Scaling of charge per delay Charge and reduction exponents carried out by multiple regressional analysis. It's divided into under loom and over 100m distance because the frequency is verified by the distance from blast site. Empirical equation of cautious blasting vibration is as follows. Over 30 ‥‥‥under 100m ‥‥‥V=41(D/$^3$√W)$\^$-1.41/ ‥‥‥A Over 100 ‥‥‥‥under 100m ‥‥‥V=121(D/$^3$√W)$\^$-1.56/ ‥‥‥B K value on the above equation has to be more specified for furthur understang about the effect of explosives, Rock strength. And Drilling pattern on the vibration levels, it is necessary to carry out more tests.

  • PDF

Radiation Characteristics of Dielectric-Coated Conducting Cylinder Loaded with Periodic Corrugation (주기적인 구형격자로 로딩된 유전체 코팅된 도체 실린더의 복사 특성)

  • Kim, Joong-Pyo;Son, Hyon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.3
    • /
    • pp.388-402
    • /
    • 2000
  • The radiation characteristics of leaky antenna from the dielectric-coated conducting cylinder with periodic corrugation are investigated theoretically for the infinite and finite periodic structures. For the infinite periodic structure, mode-matching method is applied. The integral equation is derived for the finite periodic structure by use of the Fourier transform and mode expansion and a simultaneous linear equation is obtained. The influences of the corrugation slot width, corrugation depth, dielectric thickness, cylinder radius, and finite corrugation number on the radiation characteristics (leakage constant, phase constant, and radiation pattern) are investigated. The results of the finite periodic corrugations are compared with those of the infinite extent structure and good agreement is found. To reduce high side lobe levels of the uniform finite periodic structure, tapering process on the beginning and end section of antenna and nonuniform quasi-period slot arrays are considered. Especially, for the corrugation period, width and depth used for a corrugated surface wave antenna, through the proper tapering process, end-fire radiation pattern with reduced side lobe levels is given.

  • PDF

Analysis on the Perception of Nuclear Power Plant and the Preference of its Policy Alternatives for Public Acceptance (원자력발전소에 대한 인식과 국민수용성 향상을 위한 정책대안들의 선호 분석)

  • Park, Young-Sung;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.33-44
    • /
    • 1995
  • Public acceptance has become an important factor in nuclear power program particularly after Chernobyl accident and recent rapid democratization in Korea. Methods reflecting public opinions in order to improve public acceptance are firstly to understand what the public think about nuclear power plant and secondly to find out the public preference values for its policies. For this purpose, simplified multi-attribute utility (MAU) model was applied to analyze the public perception pattern for fire power production systems. And the conjoint analysis was applied to find out the quantitative values of public preferences for twelve policy alternatives to improve the safety and to support communities surrounding nuclear power plants in Korea. To implement these perception and preference analyses, mail survey was conducted to the Qualified sample who had the experience of visiting nuclear power plant. Diagnosis of their perception pattern for five power production systems was made by the simplified MAU model. Estimation of the quantitative preference values for potential policy alternatives was made by the conjoint measurement technique, which made it possible to forecast the effectiveness of each option. The results from the qualified sample and the methods used in this study would be helpful to set up new policy of nuclear power plant.

  • PDF

A Study on the Analysis of Regional Tourism in Uijeongbu Using Big Data (빅 데이터를 활용한 의정부 지역 관광 분석 연구)

  • Lee, Jong-Yong;Jung, Kye-Dong;Ryu, Ki-hwan;Park, SeaYoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.413-418
    • /
    • 2020
  • The travel pattern of tourists for the development of the tourist course is designed to collect and analyze tourist information based on the big data of the carrier to improve the quality of the tourist course. In particular, the analyzed data is used to derive empirical data that can estimate the effect of tourists' inflow into tourism, and to utilize the information as basic data for the development of the tourist course. In addition, the travel pattern of tourists for the development of regional tourism courses is to collect and analyze information on the route and duration of tourists' travel based on big data collected by telecom operators, credit card companies and other data to improve the quality of tourist course development, and to derive empirical data to estimate the effect of tourist inflow through the analyzed data, based on the characteristics of the tourism course and the data needed for the development of new tourist courses in the future.

Comparisons of Discriminant Analysis Model and Generalized Logit Model in Stroke Patten Identifications Classification (중풍변증분류에 사용되는 판별분석모형과 일반화로짓모형의 비교)

  • Kang, Byoung-Kab;Lee, Ju-Ah;Ko, Mi-Mi;Moon, Tae-Woong;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.318-321
    • /
    • 2011
  • In this study, when a physician make a diagnosis of the Pattern Identifications(PIs) of stroke patients, the development methods of the PIs classification function is considered by diagnostic questionnaire of the PIs for stroke patients. Clinical data collected from 1,502 stroke patients who was identically diagnosed for the PIs subtypes diagnosed by two clinical experts with more than 3 years experiences in 13 oriental medical hospitals. In order to develop the classification function into PIs using the 44 items-Fire&heat(19), Qi-deficiency(11), Yin-deficiency(7), Dampness phlegm(7)- of them was significant statistically by univariate analysis in 61 questionnaires totally, we make some comparisons of the results of discriminant analysis model and generalized logit model. The overall diagnostic accuracy rate of the PIs subtypes for discriminant model(74.37%) was higher than 3% of generalized logit model(70.09%).