A Study on the Problems and Character for Management of Fire Prevention at the Wholesale Markets (도매시장 화재안전관리 측면에서의 특성 및 취약요소에 관한 연구)

  • Park, Jae-Sung;Im, Jae-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.150-158
    • /
    • 2010
  • There are lots of buildings with their deterioration in wholesale markets which have high concentration that can cause big fire due to difficulty of installing fire protection system in fire compartment, absence of safety awareness, access by many and unspecified people. There had been big fire that caused by these kind of fire weakness such as Seomun Market's in 2005 which costed tens of millions dollar, Dongmun Shopping District’s with 7 casualties. Now counter-measure against these fire is urgently needed. This study drew characteristic of current condition of wholesale markets and the one classified by main agent, fire cases and prevention of fire through statistical data. Also, current condition of fire prevention management and actual state were investigated by conducting a survey of person in charge of fire prevention and current practician. As a result, it was shown that securing professionalism of fire prevention, improvement of structural weakness of buildings, obtaining reliability on performance of fire protection system and internal fire education against practician in the market are needed.

A Study on the Improvement of Safety Management by Analyzing the Current Status and Response System of Forest Fire Accidents (산불사고 현황과 대응체계 분석을 통한 안전관리 개선방안 연구)

  • Jeong, Kyung-ok;Kim, Dae-jin
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.457-469
    • /
    • 2022
  • Purpose: The purpose of this study is to present the direction of improvement of safety management by reviewing the current status of forest fire accidents that are becoming larger throughout the year and the problems of the response system. Method: Domestic and foreign literature survey and statistics of recent forest fire accidents by Statistics Korea investigated and analyzed the cause, number of damage, and suggested ways to improve forest fire safety management through domestic and foreign forest fire response systems. Result: Through the analysis of the causes of recent wildfires and overseas response cases, measures to improve the safety management of wildfires in terms of hardware, software, and humanware were derived. Conclusion: The plan to improve forest fire safety management was classified into three main categories and presented, and it should be embodied through further related research.

Urgent demand of Improvement in management system for Korean traditional architecture (현대기술의 사각지대 전통건축물 전기설비 분야 개선 시급)

  • Lee, Gi-Sik
    • Journal of the Korean Professional Engineers Association
    • /
    • v.41 no.3
    • /
    • pp.40-44
    • /
    • 2008
  • Many traditional architectures of Korea were lost due to fire accident caused by various reasons. It has been reported that faulty electric facility is the major cause of fire. Protecting and preserving the traditional architectures under current management system and electric facility regulation are difficult. Therefore establishing early stage fire extinguishment process and management system is urgent as well as eliminating the cause of fire.

  • PDF

Mechanism analysis through Water fire case (정수기 화재발생 사례를 통한 재현실험)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.593-618
    • /
    • 2011
  • Development of the economy and the growing income of people interested in the leisure and health has been focused. Past the town common wells and groundwater around the water, but health is a priority these days to solve the drinking water directly from tap water, but most people work from home, through the water purifier has been resolved. Depending on seasonal changes and personal taste of coffee, if you can enjoy a snack and water purifier is a restaurant, lounge, public areas and focusing on the rapid spread of the fire, water purifier as compared to the total number of fires increased by 0.03% per year trend on, but the washrooms fire and fire-related research data and case studies with analysis of the exact cause lack of proper preventive measures are insufficient reality. In this study, focusing on electrical energy using a water cooler to understand the structure and principles of fire, the fire revealed the mechanism is vulnerable to the consideration of factors, the exact cause of the fire investigation and the Assistant, manufacturing defects, and to contribute to fire prevention review should.

  • PDF

A Phenomenological Studies on Ignition Characteristics of Wires by Local Impact, Over Loading and Overcurrent (국부적 충격, 과부하 및 과전류에 의한 전선의 발화특성에 관한 현상학적 연구)

  • Lee, Jeong-Jin;Lee, Chang-Woo;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.53-60
    • /
    • 2010
  • When a fire breaks out, it is difficult to find out the causes of the fire, because combustible things around fire scene are usually burnt away. Among many causes of fires are electronic wires, this thesis deal with the destroyed sheath of electronic wires caused by fire. It was studied with the use of measurement devices focusing on the distinctions of wires and conductors. This study especially emphasized the process of deterioration, burning pattern, and composition of electronic wire conductor. It also has a phenomenological approach to the distinctive cause of fire by some partial force. The fire prevention methods have been suggested through the analysing results of fire patterns. This study is expected to be a useful material for analyzing various electrical fires.

Effect Evaluation of Forest Fire on Governor Station (정압기지에 대한 산불화재 영향평가)

  • Jang, Seo-Il;Char, Soon-Chul;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.2
    • /
    • pp.49-57
    • /
    • 2007
  • This Study is to suggest a method of effect evaluation of forest fire on governor station in shrub land. Theoretically, to evaluate effects of forest fire, it is combined that Spread Rate of Forest Fire, Flame Model, and Thermal Radiation Effects Model; i.e. a travel time of forest fire is calculated by Spread Rate of Forest Fire, fire-line intensity is calculated by Flame Model, and effects of fire-line intensity is affected by Thermal Radiation Effects Model. With the aforementioned method, we could carry out the effect evaluation of forest fire on governor station in shrub land and could distinguish scenarios to need protection plan from all scenarios.

The Relationship between Job Satisfaction and Turnover Intention among Fire Protection System Management Workers (소방시설관리업 종사자의 직무만족과 이직의도와의 관계)

  • Lim, Kyoung-Yeon;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.142-151
    • /
    • 2019
  • This study examined job satisfaction among fire protection system management workers in the fire industry and analyzed how job satisfaction affects turnover intention. The results revealed that, among the control variables, including age, rank, academic background, payment, total career, license, and tasks, significant differences in job satisfaction were found in the tasks between groups, while no significant differences in turnover were found in any control variable between groups. Additionally, the results revealed that, among the lower variables of job satisfaction, increased satisfaction with payment and organizational system affected the degree of turnover intention, while work and promotion did not. These results are to be used as data for human management of technicians and for creating alternatives. Future studies are required to establish a reasonable task rotation cycle for raising job satisfaction, to examine the current status of low-cost orders and countermeasures, and to analyze the direction of development of fire protection system management business.

Development of Algorithm for Analyzing Priority Area of Forest Fire Surveillance Using Viewshed Analysis (가시권 분석을 이용한 산불감시 우선지역 선정 방안)

  • Lee, Byung-Doo;Ryu, Gye-Sun;Kim, Sun-Young;Kim, Kyong-Ha;Lee, Myung-Boa
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.126-135
    • /
    • 2011
  • In this study, the algorithm for priority area of forest fire surveillance was developed to enhance the effectiveness of fire detection. The high priority surveillance area for forest fire detection was defined as the area with not only low value of viewshed analysis of the lookouts and detection cameras but also high fire occurrence probability. To build the priority map, fuzzy function and map algebra were used. The analysis results of Bonghwa-gun, Gyeongbuk Province, showed that the surveillance priority of central and southern area is higher than north area. This algorithm could be used in the allocation of fire prevention resources and selection of suitable point for new fire detection system.

A statistics and study of fire cause by electrics (전기로 인한 화재 원인 통계와 고찰)

  • Lee, Young-Soo;Kim, Myeong-Soo;Hawng, Byung-Pyo;Kim, Hyeong-Soo;Song, Young-Hak
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.47-57
    • /
    • 2007
  • If it were the occurrence of fire by electricity with the rapid growth of economy, it would be serious damage for nation that effect human life and properties. To prevent electrical fires, it was basic countermeasure that make detail statistics classified by the source, place etc. with examining correct cause of fire. In this paper, we analuzed the present condition of fire occurrence of the lastest ten years and classified fires by the source, place, month in 2006. In addition our corporation staff execute in-depth and professional research on the actual state of electrics fire by visiting fire stations fire of the whole country for 8,554 electric fires in 2005. I expect this thesis to be used for preventing electric fires and providing a stepping stone on correct production of fire statistics.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계)

  • Han, Su-Jin;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF