• Title/Summary/Keyword: Fire initiation

Search Result 34, Processing Time 0.024 seconds

Collapse Initiation and Mechanisms for a Generic Multi-storey Steel Frame Subjected to Uniform and Travelling Fires

  • Rackauskaite, Egle;Kotsovinos, Panagiotis;Lange, David;Rein, Guillermo
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.265-283
    • /
    • 2021
  • To ensure that fire induced collapse of a building is prevented it is important to understand the sequence of events that can lead to this event. In this paper, the initiation of collapse mechanisms of generic a multi-storey steel frame subjected to vertical and horizontal travelling fires are analysed computationally by tracking the formation of plastic hinges in the frame and generation of fire induced loads. Both uniform and travelling fires are considered. In total 58 different cases are analysed using finite element software LS-DYNA. For the frame examined with a simple and generic structural arrangement and higher applied fire protection to the columns, the results indicate that collapse mechanisms for singe floor and multiple floor fires can be each split into two main groups. For single floor fires (taking place in the upper floors of the frame (Group S1)), collapse is initiated by the pull-in of external columns when heated beams in end bays go into catenary action. For single floor fires occurring on the lower floors(Group S2), failure is initiated (i.e. ultimate strain of the material is exceeded) after the local beam collapse. Failure in both groups for single floor fires is governed by the generation of high loads due to restrained thermal expansion and the loss of material strength. For multiple floor fires with a low number of fire floors (1 to 3) - Group M1, failure is dominated by the loss of material strength and collapse is mainly initiated by the pull-in of external columns. For the cases with a larger number of fire floors (5 to 10) - Group M2, failure is dominated by thermal expansion and collapse is mainly initiated by swaying of the frame to the side of fire origin. The results show that for the investigated frame initiation of collapse mechanisms are affected by the fire type, the number of fire floors, and the location of the fire floor. The findings of this study could be of use to designers of buildings when developing fire protection strategies for steel framed buildings where the potential for a multifloor fire exists.

Individual Behavioral Response in an Emergency (비상시 개인별 대응행동)

  • Jeong, Hyun-Gyu;Song, Yong-Sig;Cho, Won-Chol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.625-628
    • /
    • 2008
  • The behavioral response of the individuals intimately involved with the initiation of the fire or those who aware of the initial fire cue, often appeared to be a determinant to the outcome of the fire incident, the nonadaptive flight or panic type behavioral response appears to be an infrequent, unusual or unique participant behavioral response in most fire incidents. Therefore, this study focused on the investigation of the individual behavioral responses depend on the distinction of sex and age.

  • PDF

A Study on the Riskiness of Dust Explosion of Feed-Stuff (가축사료의 분진폭발 위험성에 관한 연구)

  • 이창우;함영민;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.61-68
    • /
    • 1998
  • According to the results for the thermodynamic stability of feed-stuff dust, there are little change of initiation temperature of heat generation and heating value for used particle size. But initiation temperature of heat generation decreased with high heating rate whereas decomposition heat increased with particle size. Using the supporting gas, O2, initiation temperature of heat generation decreased remarkably than using the inert gas, N2, and heating value increased as twenty times under the same condition. When the ignition energy is given from the outside, used fine particle which can float in the air easily reacted tremendously with oxygen. Average maximum explosion pressure was 6.88 Kgf/$\textrm{cm}^2$ for 80/100 mesh.

  • PDF

Design and Reliability Analysis of the Through Bulkhead Initiation Module for Arm-Fire-Device(AFD) (점화안전장치용 격벽 착화모듈 설계 및 신뢰도 분석)

  • Jang, Seung-Gyo;Cha, Hong-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.273-276
    • /
    • 2008
  • A Through Bulkhead Initiation Module(TBIM) has been designed which guarantees the seal property without using O-ring. The TBIM works as the shock wave generated by a donor charge transmits to the acceptor charge. The structural safety of TBIM housing has been calculated via modeling analysis, and the ignition performance has been proved by 10 cc closed bomb test. The reliability analysis has been made using Probit method on the base of performance test results. According to the reliability analysis the bulkhead thickness of TBIM which is the most important design parameter has been determined.

  • PDF

Fire Simulation by Pyrolysis Method of FDS for the Small Cone Calorimeter (ISO 5660) (FDS 열분해 모델을 이용한 콘칼로리미터(ISO 5660) 화재 시뮬레이션)

  • Yang, Sung-Jin;Jang, Jung-Hun;Kang, Chan-Yong
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.206-212
    • /
    • 2009
  • Chemical behaviors of each surface material for interior facilities affect to fire initiation and growth in general fire situation. These chemical behaviors were characterized by thermal properties (Heat release rate, Pyrolysis rate, specific heat, etc) which could be derived from experimental test. Especially, Heat release rate which indicates aspect of fire size is one of the most important property to asses fire hazard and protection needs. The cone calorimeter test (ISO 5660) has recently assumed to a dominant role in bench scale fire testing to obtain the Heat release rate of materials. This value could be calculated by the 'Oxygen Consumption Method' under various producing irradiances to each surface of materials. In this study, Process of the cone calorimeter test was simulated by Pyrolysis model of FDS (Fire Dynamics Simulator by NIST) base on the ISO 5660 international standard. Then, we could estimate the simulation method of FDS in case of single materials through the comparative study with test results.

  • PDF

Assessment of Fire-induced Damage to Tunnel Structural Members at Different Fire Scenarios (화재이력에 따른 터널구조물 시공재료의 화재손상 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Kwon, Jong-Wook;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.960-969
    • /
    • 2006
  • In this study, a series of fire tests was carried out to evaluate fire-induced damage to structural members in tunnels. From the tests, the loss amount of concrete materials by the RWS fire scenario was slightly bigger than by the RABT fire scenario. Especially under the RWS fire scenario where the maximum temperature is over 1,200, the loss of concrete materials was mainly induced by melting. Generally, the loss of materials in reinforced concrete was slightly smaller than that in unreinforced concrete. Depending upon an applied fire scenario, fire-induced damage to shotcrete was quite different. From the real-time investigation of a specimen surface by a digital camcorder, it was proved that the material loss under the RABT fire scenario was mainly induced by spalling. However, it was also revealed that although fire-induced damage in the initial heating stage under the RWS was so close to that under the RABT, the material loss under the RWS at the later stage after 50 minutes elapsed since fire initiation was induced not by spalling but by melting.

  • PDF

The Design and Implementation of the Fire Spot Display System Using s Smart Device (스마트 기기를 이용한 화점 표출 시스템의 설계 및 구현)

  • Kim, Sang-Gi;Kim, Dong Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1287-1292
    • /
    • 2018
  • In case of fire, the information related with the fire need to be provided to fire fighters in order to extinguish the fire efficiently. However, existing fire detection systems have the problem not to provide the data of the fire to fire fighters visually. In this paper, we propose the fire spot system using a cloud server to solve this problem. In the proposed system, the sensors installed in a building collect the gas and temperature data and store them into the cloud database using a wireless network. For fire fighters in the field, the details and history of the fire spot are displayed visually on top of the blue print retrieved from the cloud database using a smart device.

A Full-scale Fire Test of an Apartment House (공동주택 실물화재 실험)

  • Kim, Myung-Bae;Han, Yong-Shik;Choi, Byung-Il;Do, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2009
  • To research about the fire spread in Korean apartment house, a full-scale fire test in a four-story apartment was executed. The fire started at the third floor, and originated from overheated cooking oil in the kitchen. The apartment included all combustibles in general house. Through measuring temperature, measuring the concentration of oxygen and observing, we investigated the fire spread inside the apartment house. As a result, we got the data of the time needed for the initiation of fire, the time for fire to spread into each area in the house, and the time required until flash-over was seen. Also we grasped the understanding of the fire spread to the upper floor.

The onset of extreme fire behaviour in a mine drift

  • Hansen, Rickard
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.282-290
    • /
    • 2018
  • The onset of extreme fire behaviour in a mine drift with longitudinal ventilation was analysed. A fire in a mine drift with continuous fuel load, involving several separate fires may lead to flames tilted horizontally and filling up the entire cross section. This will lead to earlier ignition, higher fire growth rate, higher fire spread rate and a severe fire behaviour. The focus has been on what changes take place at the onset and signs of the impending phenomenon. It was found that the fire gas temperature at the ceiling level provided a poor indicator. At the downstream far-field region of the fire, the sudden temperature increase at the lowest levels of the cross section and the sudden increase in flow velocities would provide signs of extreme fire behaviour. The corresponding full-scale heat release rates of the experiments at the onset of extreme fire behaviour were found to be very high for mining applications but not necessarily for tunnel fires. The heat release rate threshold for a mine drift with smaller cross-sectional dimensions would decrease considerably, increasing the likelihood of occurrence. The distance between the fuel items will play an important role during the initiation of horizontal flames.

AN INTRODUCTION TO SEMICONDUCTOR INITIATION OF ELECTROEXPLOSIVE DEVICES

  • Willis K. E.;Whang, D. S.;Chang, S. T.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.21-26
    • /
    • 1994
  • Conventional electroexplosive devices (EED) commonly use a very small metal bridgewire to ignite explosive materials i.e. pyrotechnics, primary and secondary explosives. The use of semiconductor devices to replace “hot-wire” resistance heating elements in automotive safety systems pyrotechnic devices has been under development for several years. In a typical 1 amp/1 watt electroexplosive devices, ignition takes place a few milliseconds after a current pulse of at least 25 mJ is applied to the bridgewire. In contrast, as for a SCB devices, ignition takes place in a few tens of microseconds and only require approximately one-tenth the input energy of a conventional electroexplosive devices. Typically, when SCB device is driven by a short (20 $\mu\textrm{s}$), low energy pulse (less than 5 mJ), the SCB produces a hot plasma that ignites explosive materials. The advantages and disadvantages of this technology are strongly dependent upon the particular technology selected. To date, three distinct technologies have evolved, each of which utilizes a hot, silicon plasma as the pyrotechnic initiation element. These technologies are 1.) Heavily doped silicon as the resistive heating initiation mechanism, 2.) Tungsten enhanced silicon which utilizes a chemically vapor deposited layer of tungsten as the initiation element, and 3.) a junction diode, fabricated with standard CMOS processes, which creates the initial thermal environment by avalanche breakdown of the diode. This paper describes the three technologies, discusses the advantages and disadvantages of each as they apply to electroexplosive devises, and recommends a methodology for selection of the best device for a particular system environment. The important parameters in this analysis are: All-Fire energy, All-Fire voltage, response time, ease of integration with other semiconductor devices, cost (overall system cost), and reliability. The potential for significant cost savings by integrating several safety functions into the initiator makes this technology worthy of attention by the safety system designer.

  • PDF