A Study on Mitigating Accidents for Liquid Hydrogen (액체수소 사고피해 완화기술에 대한 연구)

  • Jo, Young-Do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.29-33
    • /
    • 2012
  • This paper is an attempt to give a concise overview of the state-of-the-art in the recent liquid hydrogen safety researches with unwanted event progress. The vessel of liquified hydrogen may fail and liquid hydrogen spilled. The hydrogen will immediately start to evaporate above a pool and make a hydrogen cloud. The cloud will disperse and can produce a vapor cloud explosion. The vessel containing the liquid hydrogen may not be able to cope with the boil-off due to heat influx, especially in case of a fire, and a BLEVE may occur. In equipment where it exists as compressed gas, a leak generates a jet of gas that can self-ignite immediately or after a short delay and produce a jet flame, or in case it ignites at a source a certain distance from the leak (delayed ignition), a flash fire occurs in the open and with confinement a deflagration or even detonation may develop. The up-to-date knowledge in these events, recent progress and future research are discussed in brief.

A Study on the Inflammable Gas Explosion Triggered by the Electric Discharge Static Eliminator on Voltage Application Type (전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구)

  • Lee Chun Ha;Ok Kyoung Jea;Kim Jum-Ho;Kwon Byung-Duck;Cha Ha-Na;Yun Kea Won
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.22-26
    • /
    • 2004
  • The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode.

The Arc Dispersion Properties by Switching of High Sensitivity Type RCD Contacts (고감도형 누전차단기 접점의 스위칭에 따른 아크 비산 특성)

  • Choi Chung-Seog;Kim Dong-Woo;Kim Young-Seok;Lee Ki-Yeon
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.63-68
    • /
    • 2005
  • In this study, the arc dispersion properties were analyzed according to switching of high sensitive type Residual Current Protective Device(RCD) contacts. Arc dispersion and ignition process was taken by high speed imaging system(HSIS). In this experiment, electric lamps(60 W) and heaters(950 W) were connected in parallel as loads. In case of normal RCD, it took about 2.3(ms) from the generation of arc to the extinction of uc. When arc was dispersed in normal RCD, it did not ignite cotton. Whereas, in case of RCD deteriorated by NaCl solution, the range of arc dispersion was wider and the arc lasted for 3.3[ms] more compared to normal RCD. And the arc ignited cotton. In order to prevent accidents caused by RCD, we should be careful of environmental factors, such as dust and humidity, and the parts of RCD should be used as incombustible materials.

Risk evaluation of EVA dust with oxidizer by a pressure vessel (압력용기시험에 의한 EVA분진의 혼촉 위험성 평가)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.7-12
    • /
    • 1999
  • Thermal properties of EVA dust and its risks of coexisting with oxidizer were investigated by a pressure vessel. The decomposition of EVA dust with temperature using DSC and the weight loss with temperature using TGA were also investigated to find the thermal hazard of EVA dust. Using the pressure vessel which can estimate ignition and explosion of EVA dust coexisting with oxidizer by bursting of a rupture disc, many experiments have been conducted by varying the orifice diameter, heating rate, the weight ratio of the sample coexisting with oxidizer, and the species of oxidizer. According to the results of the thermal analysis of EVA dust, a little change of the decomposition initiation temperature with the heating rate could be found and the decomposition temperature zone of EVA dust was 250 to 50$0^{\circ}C$. The risk of EVA dust coexisting with oxidizer was increased as the orifice diameter was decreased. On the other hand, it was increased as the heating rate and the weight ratio of the sample coexisting with oxidizer were increased. In addition, the risk of EVA dust coexisting with oxidizer was affected by the decomposition temperature of the sample and oxidizer, respectively, at slow heating rate, but it was affected by the oxygen weight percent of oxidizer at fast heating rate.

  • PDF

A Study on Combustion Characteristics of Flame Retardant Treated Pinus Densiflora (방염처리 육송의 연소특성 연구)

  • Choi, Jung-Min;Ro, Ho-Seung;Jin, Young-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.57-62
    • /
    • 2011
  • The combustion characteristic was evaluated for Pinus densiflora, used as a building material in Hanok, which were treated with two different flame retardant method. The specimen was brushed with flame retardant liquid two or three times and then let the specimen dehydrated during 24 h for spreaded treating. And the other specimen was soaked in the liquid for 72 h. The test methods were inflammability test using meker burner and heat release rate test using cone calorimeter. As a result for the tests, flame retardant treated specimens met the requirements of the inflammability and the spreaded treated method was more efficient than immersed method. The spreaded treated specimen had lower combustive properties than immersed specimen in TTI (time to ignition), PHRR (peak heat release rate), MLR (mass loss rate) and THR (total heat release).

Measurement and Investigation of Combustible Characteristics for Risk Assessment of Toluene (톨루엔의 위험성 평가를 위한 연소특성치 측정 및 고찰)

  • Ha, Dong-Myeong;Jeong, Kee-Sin
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.76-81
    • /
    • 2010
  • For the safe handling of toluene, explosion limit at $25^{\circ}C$ and the temperature dependence of the explosion limits were investigated. And flash point and AIT (Autoignition Temperature) for toluene were experimented. By using the literature data, the lower and upper explosion limits of toluene recommended 1.13 vol% and 7.9 vol%, respectively. In this study, measured the lower and upper flash points of toluene by air-blowing tester were $5^{\circ}C$ and $40^{\circ}C$, respectively. And measured the upper flash points of toluene by Setaflash tester was $41.5^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for toluene, and the experimental AIT of toluene was $547^{\circ}C$. The new equations for predicting the temperature dependence of the explosion limits of toluene is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

Risk Assessment of Fire and Explosion of Methane (메탄의 화재 및 폭발 위험성 평가)

  • Ha Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.1-7
    • /
    • 2005
  • The thermochemical parameters for safe handling, storage, transport, operation and process design of flammable substances are explosive limit, flash point, autoignition temperature, minimum oxygen concentration, heat of combustion etc.. Explosive limit and autoignition temperature are the major physical properties used to determine the fire and explosion hazards of the flammable substances. Explosive limit and autoignition temperature of methane fur LNG process safety were investigated. By using the literatures data, the lower and upper explosive limits of methane recommended 4.8 vol$\%$ and 16 vol$\%$, respectively. Also autoignition temperatures of methane with ignition sources recommended $540^{\circ}C$ at the electrically heated cruicible furnace (the whole surface heating) and recommended about $1000^{\circ}C$ in the local hot surface. The new equations for predicting the temperature dependence and the pressure dependence of the lower explosive limits for methane are proposed. The values calculated by the proposed equations were a good agreement with the literature data.

  • PDF

The Experimental Study on the Lift-off Height due to Momentum Ratio in Swirl-Coaxial Injector (2유체 동축인젝터의 공급 운동량비가 화염부상거리에 미치는 영향에 관한 실험적 연구)

  • Moon, I.Y.;Kim, Y.;Park, H.H.;Kim, S.J.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.30-35
    • /
    • 2000
  • The experimental study on the lift-off height of diffusion flames was conducted to investigate the damage of swirl-coaxial injector used in $GO_2$/kerosene rocket engine during initial stage of ignition. To investigate the causes of damage and to prevent further damage of the injector, experimental injector was designed and hot fire tests were performed with varying propellant momentum ratio($\frac{Momentum of {GO_2}}{Momentum of Kerosene}$) from 1 to 12. In experimental coaxial injector, kerosene is sprayed from the central nozzle with swirl and $GO_2$ sprayed around the kerosene nozzle in the direction parallel to the axis of combustion chamber. Chamber pressure are close to the atmospheric condition. Lift-off height was measured by still images from camcoder and average values were used as data.

  • PDF

Numerical Study on the Effects of Surface-inhibitors on the Spontaneous Ignition of Coal Stockpile (저탄장 자연발화에 미치는 표면차단제 영향에 관한 수치 해석적 연구)

  • Kim, Jae-Kwan;Park, Seok-Un;Shin, Dong-ik
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.20-29
    • /
    • 2019
  • In this paper, the effect of spontaneous combustion inhibitor on the surface of coal stockpile in coal yard was investigated by numerical analysis. First, the numerical analysis method of the present study was compared with the results of the previous study by analyzing the case where the spontaneous combustion inhibitor was not applied, and the effect of preventing spontaneous combustion by various areas and positions for spraying spontaneous combustion inhibitor was analyzed. As a result, the larger the application area of the spontaneous combustion inhibitor, the more the effect of preventing spontaneous combustion by blocking the oxygen inflow into the coal stockpile, and the greater the effect of the spontaneous combustion prevention when spraying spontaneous combustion inhibitor from the bottom of the coal stockpile. Spontaneous combustion inhibitor should be sprayed effectively, considering the economic aspects, such as manufacturing cost etc.

IoT Platform System for Electric Fire Prediction and Prevention (전기화재 예측 및 예방을 위한 IoT 플랫폼 시스템)

  • Yang, Seungeui;Lee, Sungock;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.2
    • /
    • pp.223-229
    • /
    • 2022
  • During the winter season, when the weather gets colder every year, electricity consumption increases rapidly. The occurrence of fires is increasing due to a short circuit in electrical facilities of buildings such as markets, bathrooms, and apartments with high population density while using a lot of electricity. The cause of these short circuit fires is mostly due to the aging of the wires, the usage increases, and the excessive load cannot be endured, and the wire sheath is melted and caused by nearby ignition materials. In this paper, the load and overheat generated in the electric wire are measured through a complex sensor composed of an overload sensor, a VoC sensor, and an overheat sensor. Based on this, big data analysis is carried out to develop a platform capable of predicting, alerting, and blocking electric fires in real time, and a simulator capable of simulated fire experiments.