A Numerical Study of the Backdraft Behavior with the Variation of the Ignition Location and Time (점화원 위치 및 점화시간 변화에 따른 백드래프트 거동에 관한 수치적 연구)

  • Ko, Min Wook;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • The behavior of backdraft in the compartment with different ignition locations and times was numerically investigated. The Fire Dynamics Simulator (FDS) v5.5.3 with a model-free simulation option was used in the numerical simulation of backdraft. The ignition source was located near the inside wall, at the compartment center and near the window opening, respectively. The ignition was started at the instance when the fresh air reached the ignition location or when a sufficient time passed compare to the instance of the arriving of the fresh air to the ignition location. As a result, for the ignition source was located near the inside wall, a strong fire ball was observed at once and the result was similar to the previous experimental result. For the ignition source was located at the center of the compartment, a strong fire ball was occurred and two strong fire balls were observed consecutively for the ignition time was delayed. For the ignition source was located near the window opening and longer time was given for the ignition compare the duration of the fresh air arriving to the ignition location, the rapid temperature variation was not observed because there was no flame. However, for the ignition was started at the instance when the fresh air reached the ignition location, the ignition could be initiated and a intensive fire ball was observed. The pressure measured at the upper inside part of the window opening provided a similar trend with the previous experimental result of compartment backdraft.

Fire Risk Analysis through Airfryer's Fire Cases and Reproduction Experiments (에어프라이어의 화재사례와 재현실험을 통한 화재위험성 분석)

  • Lee, Jung-Il;Jo, Myeng-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.39-46
    • /
    • 2020
  • This paper recognizes the risk of ignition of air fryer (machine that can cook fried dishes with hot air without oil) that is far exceeding the sales rate of microwave ovens, which is necessary to modern household kitchen, and identifies fire risk through the operation principle of the process of heat transfer, and the main structure of the machine. The fire test that we conducted is to observe the risk of ignition of the machine due to the damage to the safety system and the possibility of igniting oil paper along with food, to experiment with the possibility of ignition due to blockage of the exhaust due to obstacles, and accumulation of oil stains on the hot wire, and to present the method of fire control and devise countermeasures.

A Study on the Afforestation of Fire-Resistant Forest through an Application of Forest Fire Investigation (산림 화재감식 응용을 통한 내화림 조성에 관한 연구)

  • Park, Young-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.118-129
    • /
    • 2011
  • In this study, species resistant to forest fire were extracted from high trees through an investigation of combustion mechanism. Here, the average flameless ignition temperatures of living leaves, branches and barks of oak were respectively, $365^{\circ}C$, $440^{\circ}C$ and $435^{\circ}C$, and the average flameless ignition temperatures of living leaves, branches, barks and cones of pine tree were respectively, $320^{\circ}C$, $405^{\circ}C$, $435^{\circ}C$ and $363^{\circ}C$. It shows that generally, pine tree has a lower flameless ignition temperature than oak and thus, has a relatively high risk of flameless ignition. When comparing risk of fire depending on ignition characteristics, Quercus serrata had a low risk of stem fire, and Quercus acutissima and Quercus serrata had a low risk of crown fire, as well. When analysing risk of fire depending on a duration of flame, also, Quercus dentata had a low risk of stem fire, and Quercus variabilis Blume had a low risk of crown fire too. Lastly, when comparing risk of fire, according to heat release rates, Quercus acutissima had a low risk of stem fire, and Quercus acutissima and Quercus dentata had a low risk of crown fire, as well. In conclusion, it was observed that as fire-resistant species, Quercus serrata and Quercus dentata have a low risk of ignition, Quercus variabilis Blume has a short duration of flame after discharging ignition when a forest fire occurs, and Quercus acutissima, Pinus Rigida and Antipathes japonica Brook have low heat release rates.

Design and Implementation of the Automatic Fire Extinguishing System Based on the Ignition Point Tracking using the Flame Detecter (화재감지기를 사용한 발화점추적기반의 자동소방시스템 설계 및 구현)

  • Paik, Seung Hyun;Kim, Young Wung;Oh, Se Il;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.3
    • /
    • pp.155-161
    • /
    • 2013
  • To reduce the personnel and material loss caused by fire, we propose the automatic fire extinguishing system based on the ignition point tracking using the flame detecter. This automatic fire extinguishing system is composed of the flame detecting system and the fire extinguishing system based on the water cannon. We study the method for the ignition point tracking and the automatic fire extinguishing using the water cannon and the flame detecter. The flame detecting system for the early fire detection and the ignition point tracking has to be satisfied the requirement of the detecting range and the flame detection time. So we study the signal process algorithm for an improvement of the flame detecting system.

A Study on Possibility of fire ignition by Lime(CaO) (생석회에 의한 발화 가능성 연구)

  • Noh, Jeong-Yeob;Lee, Eui-Pyeong
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.102-116
    • /
    • 2011
  • With the spread of FMD and AI in the country livestock farmers have used lime(CaO) prevalently and due to incorrect storage lime served as a fire ignition source in a number of cases. As combined chemically with water, lime has exothermic reaction. Then In these experiments we want to know how exothermic reaction - caused by lime - acts as sources of fire ignition in any circumstances and conditions. So we have done experimental work of ignition temperature and ignition process in the artificial conditions as lime combined chemically with water. As a result, we have confirmed that lime could be flammable material sufficiently as a fire ignition source with the proper presence of heat and moisture conditions. If the lime served as sources of fire ignition, as identification techniques of fire scene, we must ascertain the existence of water, flammable material and Calcium Hydroxide($Ca(OH)_2$). We should take special precautions in order to prevent fire and educate the safe handling of lime to the manufacturer and agricultural cooperative's joint livestock farmers who product or use lime.

  • PDF

A Study on the Spontaneous Ignition Possibility of Shredded Waste Thermoplastic Elastomer (폐 열가소성 플라스틱 탄성체 분쇄물의 자연발화가능성에 관한 연구)

  • Park, Young Ju;Lee, Hae Pyeong;Goh, Kyoung Chun;Eom, Young Sup
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • In this study, we considered the ignition possibility for the shredded thermoplastic elastomer at the fire ground loaded the waste TPE. The average moisture content of the TPE sample was almost 0.33 wt.% at $110^{\circ}C$ and the range of ignition point was $461.9{\sim}491.9^{\circ}C$ approximately. In addition, we analyzed the change of weight and calorie the TPE sample according to temperature variations using the TG-DTA analyzer. As a result, the weight loss occurred twice in $250{\sim}420^{\circ}C$ and $420{\sim}473^{\circ}C$, and we found the second weight loss temperature range was the ignition point of TPE. Also, we conducted the spontaneous ignition tests of TPE for the wet and dry samples and we confirmed that the possibility of spontaneous ignition of TPE was very low. The elapsed time and humidity had little influence on the spontaneous ignition of TPE in this experimental conditions. In conclusion, the spontaneous of the shredded waste TPE in this study.

A Study on the Fire Hazards of Puzzle Mats in Group Day Care Home (놀이방 퍼즐매트의 화재위험성에 관한 연구)

  • Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.73-78
    • /
    • 2008
  • The fire hazards and combustion heat of puzzle mats in group day care home were analysed using variable external irradiation level. The fire hazards such as ignition time, ignition temperature, mass loss rate, and flame temperature profile were measured. Incident heat fluxes of $15kW/m^2$, $20kW/m^2$, $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $75kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminium foil. Each sample was nominally 20mm thick and 100mm square. Five samples of puzzle mat were tested in the study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. As results, Type E of FR-grade showed the best characteristics in safety of the early fire from ignition time, critical heat flux, and ignition and flame temperature data of this study. All specimen of G-grade(Type A, B and C), however, showed the weak in safety of fire.

A Study on the Comparative Analysis of Hand Calculations and Fire Simulation for Estimating Fire Spread Paths in Jecheon Sports Center (제천스포츠센터 화재확산경로 추정을 위한 예측식 및 화재시뮬레이션 비교 분석에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.51-52
    • /
    • 2022
  • In previous studies, fire simulation was used to estimate the fire spread path. According to previous studies, the fire spread path was estimated to be the main staircase, but consideration of interior materials and internal bulkheads was insufficient. In this study, the ignition time of the 3rd layer was analyzed using the prediction formula considering the interior materials and internal bulkheads. As a result of referring to the architectural drawings, it was found that the interior material of the 3rd floor was made of polystyrene. The internal ignition time of the third floor using FDTs was calculated to be 14,070 seconds (about 234 minutes). The internal ignition time of the 3rd floor using the Handbook on Design Calculation Methods of Fire Behavior was calculated to be 3,104 seconds (about 51 minutes). As a result of calculating the ignition time through the predictive formula, there is a large difference in the ignition time, so it is necessary to review the condition of the variable as a result of the calculation in the future.

  • PDF

The Problems and Improvements of Process to Predict Fire Risk of a Building in Performance Based Design (성능위주설계에서 화재위험성 예측 과정의 문제점 및 개선방안)

  • Lee, Se-Myeoung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.145-154
    • /
    • 2014
  • Performance based design(PBD) is the method to make a fire safety design against them after predicting the factors of fire risk in a building. Therefore, predicting fire risk in a building is very important process in PBD. For predicting fire risk of a building, an engineer of PBD must consider various factors such as ignition location, ignition point, ignition source, first ignited item, second ignited item, flash over, the state of door and fire suppression system. But, it is difficult to trust fire safety capacity of the design because the process in Korea' PBD is unprofessional and unreasonable. This paper had surveyed some cases of PBD that had been made in Korea to find the problems of the process to predict fire risk. And it have proposed the improvements of process to predict fire risk of a building.

Forest Fire Ignition Patterns Caused by Farming Activities (영농활동으로 인한 산불발생 특성)

  • Koo, Kyo-Sang;Lee, Byung-Doo;Lee, Myung-Bo;Lee, Si-Young;Kim, Jeong-Hun;Park, Houng-Sek;ParK, Geon-Young
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.103-110
    • /
    • 2010
  • Farming activity was the second cause of forest fire following the carelessness. In this study, 74 forest fires caused by farming activity and waste burning in 2009 was investigated for analyzing ignition patterns. The main cause to bring about forest fire was the farming waste burning as 25 cases, burning of farming waste matter after product and household waste burning were the second causes as 19 cases. Landcovers which transfer flame from ignition point to forest were fallow field graveyard, field fruit farm, field levee fallow field. The average distance between ignition point and forest sleeve was 19 m, and the maximum distance was 130 m. The probability of forest fire ignition was high in the 100 m buffer zone from the forest sleeve that is the prohibition rule of fire use for forest fire prevention at the forest fire season.