• Title/Summary/Keyword: Fire gas

Search Result 1,029, Processing Time 0.026 seconds

A Study on Toxicity Bio-markers of a Mouse using Combustion Gas SO2 generated from Fire (마우스(mouse)를 이용한 건축물 마감재료 연소가스 SO2의 독성생체지표 연구)

  • Rie, Dong-Ho;Cho, Nam-Wook;Choi, Soon-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.43-51
    • /
    • 2012
  • This study was carried out to observe the impacts of a mouse's inhalation of toxic gas SO2 generated from combustion on its organs by different concentrations. As for research methods: First, after concentrations of SO2 generation from combustion had been set to three: low (10.4 ppm), middle (24.9 ppm) and high (122 ppm) through Gas Toxicity Testing Method (KS F 2271) and SO2 combustion gas was exposed to eight mice in each concentration. Five mice that were able to move based on LD50, a criterion, which sets the down time of a mouse's average behaviors to over 9 minutes, were randomly selected in each concentration, and they were set up as the subjects of the study on toxicity bio-markers. Second, tissues were taken from heart, liver, lungs, spleen and the thymus gland of the mice selected in each concentration and a pathological examination of them was carried out. As a result, microvascular congestion appeared in the heart, and cell necrosis, cortex congestion and tubule medulla congestion, etc. in each concentration were observed in addition to vascular congestion in liver, lungs, spleen and the thymus gland. Also, it was found that the higher the concentrations of SO2 exposure is, the greater, the changes in the organs get. Through this study, SO2 of various toxic gases generated from fire turned out to affect the tissues of each organ of a mouse, it is expected that the toxic gases may greatly affect human body in case of actual fire, and this study is evaluated as having a significance as a basic data on inhalation toxicity assessment of toxic substances generated in combustion.

Consequence Analysis of Toxic Gases Generated by Fire of Lithium Ion Batteries in Electric Vehicles (전기자동차 내 리튬이온전지 화재로 발생하는 독성가스의 위험성 분석)

  • Oh, Eui-young;Min, Dong Seok;Han, Ji Yun;Jung, Seungho;Kang, Tae-sun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2019
  • As the market for portable electronic devices expands, the demand for Lithium Ion Battery (LIB) is also increasing. LIB has higher efficiency than other secondary batteries, but there is a risk of explosion / fire due to thermal runaway reaction. Especially, Electric Vehicles (EV) equipped with a large capacity LIB cell also has a danger due to a large amount of toxic gas generated by a fire. Therefore, it is necessary to analyze the risk of toxic gas generated by EV fire to minimize accident damage. In this study, the flow of toxic gas generated by EV fire was numerically analyzed using Computational Fluid Dynamic. Scenarios were established based on literature data and EV data to confirm the effect distance according to time and exposure standard. The purpose of this study is to analyze the risk of toxic gas caused by EV fire and to help minimize the loss of life and property caused by accidents.

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

A Study on Measuring of Fire Extinguishing Concentration for Organic Material Using Novec (노벡을 이용한 유기물의 소화농도 측정에 관한 연구)

  • Lim, Woo-Sub;SaKong, Seong-Ho;Jung, Jong-Jin;Nam, Dong-Gun;Choi, Kenu-Joo;An, Sang-Su;Kim, Jong-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.456-460
    • /
    • 2008
  • This study was on basic step to develop a good clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using Novec which is inert gas. In study used to Cup Burner Test its made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test. The finding is that a new clean agent, Novec has a very efficient extinguishing ability in a state of gas.

  • PDF

Extinguishing of Oil Fire by Water Mist Suppression System Using Compressed Inert Gas (불활성 압축가스를 이용한 미세물분무 소화시스템의 유류화재 소화특성)

  • Shin, Chang-Sub;Jeon, Go-Un;Kim, Ki-Whan
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.109-114
    • /
    • 2010
  • Water mist fire suppression system is environmental system and needs a flange pump to jet water. In this research, high pressure Nitrogen cylinder is used as a pressurizing source instead of flange pump, and also we tried to find the possibility of using compressed Nitrogen as a fire suppression agent. As a result, it was possible to design water mist fire suppression system with Nitrogen cylinder and suppress oil fire effectively. With DK1.58 nozzle, the optimum Nitrogen pressure was 80bar and the pressure was stable during water mist spray. However, jet of Nitrogen was not effective fire suppression agent when it was dually used with water mist because water mist has blown away, and it is efficient way to use compressed Nitrogen as a pressurizing source only.

Numerical Prediction of Smoke Concentration in a Compartment Fire by Using the Modified Volumetric Heat Source Model (수정된 체적열원모델을 이용한 실내 화재의 연기농도 예측)

  • Kim Sung-Chan;Lee Seong-Hyuk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.344-350
    • /
    • 2006
  • The present study investigates the characteristics of fire-driven heat flows and gas concentration in a compartment fire by using the modified VHS model (MVHS). The main idea of this model is to add some source terms for combustion products and oxygen consumption to the original VHS model for providing more accurate and useful information on gas concentration distributions as well as thermal fields. It is found that the present MVHS model shows fairly good agreement with the experimental data and the eddy breakup combustion model. The tilting angle of fire plume calculated by MVHS is larger than that of EBU model because the fire source of VHS is affected by ventilating flow less than EBU. However, this discrepancy is apparently reduced in the downstream region of fire source.

A study of the hazard of fire and explosion due to electric charge by Gas-Solids flow in pipeline

  • Chung Jae Hee;Seo Dae Won;Koo Ja Hyeuk;Kim Sung Jun;An Heau Seak;Kim Joon Ho;Hong Sung Kyung;YAMAGUMA Mizuki;KODAMA Tsutomu
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.33-38
    • /
    • 2000
  • When fire and explosion accidents have occurred due to a leak of the flammable gas involving the LNG & LPG in an industrialized society, it is a very important problem. Accordingly, in this paper, we have compared and analyzed the occurrence transition and the electrostatic energy according to dust supplies and pressure variations for the electric charge due to the gas-solids of pipe flow. As the experimental results, if dust amounts and the initial pressure increased, electric charge in the pipe and the exit increased. The Specific charge of $Fe_2O_3$ increased proportionally if the initial pressure increased but if the quantity of dust increased, the specific charge decreased. Energy increased significantly as the dust amounts and the initial pressure increased. The possibility of fire and explosion exist in the measuring point(M 1) and the Faraday cage if natural gas and LPG were used.

  • PDF

A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station (가스충전소에서 작업복의 정전기 안전관리에 관한 연구)

  • Lee, Geum-Hwan;Chung, Jae-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

A Study on the extent of damage from fire accident Caused by Unloading of LPG Bulk Lorry (LPG 벌크로리 충전중 화재사고에 따른 사고피해영향범위에 관한 연구)

  • Lee, Myoung Ho;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.1-4
    • /
    • 2015
  • The study analyses secondary damage of surrounding facilities from the fire accident by Unloading of LPG Bulk Lorry. Potential risk and extent of damage from jet flame and radiation heat is estimated with PHAST-RISK v6.7 program of DNV. According to above study, supplies can predict the damage range from gas release by Unloading, and be able to respond quickly.

A Study on Toxicity Evaluation of Combustion Gases Released from the Residental Container Fire - Efficiency Test for the Fire Gas Mask Filters (주거용 컨테이너 화재시 발생되는 연소가스의 독성 평가에 관한 연구 - 화재용 방독면 filter의 성능평가를 중심으로)

  • Lee Jung Yun;Kim Jeong Hun;Kim Youn-Hi;Jung Ki Chang
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.48-54
    • /
    • 2004
  • The recent Ire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2,\; CO_2,\;CO,\;NOx,\;SOx,\;HCI,\;HCN$ were measured, and blood samples of lab rats were analyzed in terms of Co-Hb, Glucose, AST(GOT), ALT(GPT), in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.