• Title/Summary/Keyword: Fire flame

Search Result 832, Processing Time 0.036 seconds

An Experimental Investigation on Fire Characteristics of Light Oil & Methanol for Spilled Surface (경유와 메탄올의 유출표면에 따른 화재특성에 관한 실험적 고찰)

  • Lee, Jung-Yon;Jung, Ki-Chang;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.103-108
    • /
    • 2010
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate, amount of radiant heat flux from light oil fire was 4 times increases compared with fire of methanol. Depending on spill locations(kinds of road surfaces, absorbing rate) and the longer the duration of the flame important factors for the internal temperature of tank truck rise was found. Dirt roads than paved road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

Experimental Study on Flame Trajectory in Building External Walls Fire (건축물 외벽화재시 Flame Trajectory 추정을 위한 실험적 연구)

  • Shin, Yi-Chul;Park, Kye-won;Jeong, Jae-Gun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.79-80
    • /
    • 2016
  • In the event of a fire on the outer walls of an architectural structure, through real scale experiments with the purpose of estimating the Flame Trajectory, the behavior and risks of expanded combustion to an upper architectural compartment of the Fire Plume Ejected from an Opening according to changes in the aspect ratio of the opening were examined. The results showed that the more the heat release rate of the fire source increased, the heat capacity of the Fire Plume Ejected from the Opening also increased, and for the case of heptane when compared with methanol or ethanol, the results showed a trend for a significant amount of unburned gas to remain. The results also showed that the larger the aspect ratio was, the more likely it was for the Flame Trajectory to approach the outer walls and rise up. In each of the experiment conditions, as the flame rose from the lower part of the wall to the upper part of the wall, a steady decrease was shown for the temperature distribution. Also by quantitatively analyzing the amount of unburned gas that remained, a method to estimate the temperature of the Fire Plume Ejected from an Opening for a traverse opening was implemented.

  • PDF

A Numerical Study of 1-D Surface Flame Spread Model - Based on a Flatland Conditions - (산불 지표화의 1차원 화염전파 모델의 수치해석 연구 - 평지조건 기반에서 -)

  • Kim, Dong-Hyun;Tanaka, Takeyoshi;Himoto, Keisuke;Lee, Myung-Bo;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.63-69
    • /
    • 2008
  • The characteristics of the spread of a forest fire are generally related to the attributes of combustibles, geographical features, and meteorological conditions, such as wind conditions. The most common methodology used to create a prediction model for the spread of forest fires, based on the numerical analysis of the development stages of a forest fire, is an analysis of heat energy transmission by the stage of heat transmission. When a forest fire breaks out, the analysis of the transmission velocity of heat energy is quantifiable by the spread velocity of flame movement through a physical and chemical analysis at every stage of the fire development from flame production and heat transmission to its termination. In this study, the formula used for the 1-D surface forest fire behavior prediction model, derived from a numerical analysis of the surface flame spread rate of solid combustibles, is introduced. The formula for the 1-D surface forest fire behavior prediction model is the estimated equation of the flame spread velocity, depending on the condition of wind velocity on the ground. Experimental and theoretical equations on flame duration, flame height, flame temperature, ignition temperature of surface fuels, etc., has been applied to the device of this formula. As a result of a comparison between the ROS(rate of spread) from this formula and ROSs from various equations of other models or experimental values, a trend suggesting an increasing curved line of the exponent function under 3m/s or less wind velocity condition was identified. As a result of a comparison between experimental values and numerically analyzed values for fallen pine tree leaves, the flame spread velocity reveals a prediction of an approximately 10% upward tendency under wind velocity conditions of 1 to 2m/s, and of an approximately 20% downward tendency under those of 3m/s.

Effect Evaluation of Forest Fire on Governor Station (정압기지에 대한 산불화재 영향평가)

  • Jang, Seo-Il;Char, Soon-Chul;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.2
    • /
    • pp.49-57
    • /
    • 2007
  • This Study is to suggest a method of effect evaluation of forest fire on governor station in shrub land. Theoretically, to evaluate effects of forest fire, it is combined that Spread Rate of Forest Fire, Flame Model, and Thermal Radiation Effects Model; i.e. a travel time of forest fire is calculated by Spread Rate of Forest Fire, fire-line intensity is calculated by Flame Model, and effects of fire-line intensity is affected by Thermal Radiation Effects Model. With the aforementioned method, we could carry out the effect evaluation of forest fire on governor station in shrub land and could distinguish scenarios to need protection plan from all scenarios.

A Study on the Ways of Securing the Effectiveness of Field Flame Retardant Coating Process (현장방염처리제도의 실효성 확보 방안에 관한 연구)

  • Park, Sung-Hyun;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.95-100
    • /
    • 2011
  • The ultimate purpose of this study is to improve the irrational system related to flame retardant coating performance test of field flame retardant coating articles and to secure the reliability of flame retardant coating through rational flame retardant coating test. To achieve this, the analysis was conducted on the interior finishing materials used in the interior fields and the trends of recent field flame retardant coating, based on the results of flame retardant coating performance test of field flame retardant coating articles which the first-line fire stations have recently conducted. And I attempted to present the methods of field flame retardant coating performance test suitable to current realities and the ways of improvement for securing reliability by analyzing the problems with the methods and procedures of field flame retardant coating articles and the registration system of flame retardant coating business.

Fire Characteristics for Spill Rate of Light oil and Methanol (경유와 메탄올의 유출속도에 따른 화재특성)

  • Lee, Jung Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.54-60
    • /
    • 2016
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate. Depending on spill rate(30, 60, 90 and $120{\ell}/min$) and the longer the duration of the flame important factors for the internal temperature of tank lorry rise was found. Road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

A Study on Signal Circuit of the Triple Pyroelectric Infrared Flame Detector (초전형 삼파장 적외선식 불꽃감지기 신호회로 개발)

  • Song, Hyun-Seon;Lee, Yeu-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.201-207
    • /
    • 2010
  • This thesis studies development of a triple pyroelectric Infrared flame detector to have appropriate reaction characteristics with proper operational features in various and radiant energy characteristics of fire sources, and to contribute to minimize the losses of human lives and properties by detecting fire in very early stage to restrict the spread of fire.

A Room-Corner Fire Model을 적용한 건축내장재의 화재확산 특성 평가(1)

  • Kim, Un-Hyeong
    • Fire Protection Technology
    • /
    • s.24
    • /
    • pp.32-39
    • /
    • 1998
  • A room-corner fire scenario of ISO 9705 with flame spread model developed by Quintiere is applied to the interior finish materials to show the sensitivity of properties derived from AST, E-1321 and ASTM E-1354 is investigated and various range of thermal properties by the author were analyzed in the model. There are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The time for total energy release rate to reach 1MW is examined. Though some areas are neede for improvements, The model appears to predict good results with all the range of input properties and could be

  • PDF

An Experimental Study on the Risk of Vertical Flame for a Extended-Balcony (발코니 확장에 따른 수직화염 확대 위험성에 관한 실험적 연구)

  • Shin, Yi-Chul;Youn, Yoo-Hyuk;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.283-288
    • /
    • 2008
  • Since installing a balcony can significantly reduce the spread of fire, fire spread to the upper levels was confirmed, comparing the cases with and without balcony extension. It was confirmed that the fire can spread not only to the next higher level but also to two levels higher due to the outburst of flame which reached a significant temperature in the case without balcony, while the possibility of fire spread to the upper level reduced considerably with the balcony. this study is compared and analyzed to vertical diffusion appearance of an externally venting flame. An installed balcony is also applied to fire test 6.54kW to analyze about effect of a balcony.

  • PDF