• 제목/요약/키워드: Fire facility

검색결과 447건 처리시간 0.033초

방화설비계통 설계용 전산소프트웨어 개발에 관한 연구 (A Study on the Development of Computer Software for the Design of Fire Protection System)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.275-284
    • /
    • 1998
  • Standard on the carbon dioxide extinguishing system was prepared by the committed of the national fire protection assocition(NFPA)in USA on 1980. And this code is also applied to the design of a marine fire extinguishing system The most important problem in design is the uniform discharge of $CO_2$ through each nozzle from the high pressure $CO_2$ storage facility. The purpose of this paper is to develop the computer software to design the marine fire protection piping system. By solving the continuity equation energy equation and Bernoulli's equation simulataneously the flowrate in branch pipelines and discharge nozzles can be calculated.

  • PDF

Experimental testing and evaluation of coating on cables in container fire test facility

  • Aurtherson, P. Babu;Hemanandh, J.;Devarajan, Yuvarajan;Mishra, Ruby;Abraham, Biju Cherian
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1652-1656
    • /
    • 2022
  • Fire tests were conducted on cables using fire-retardant paint employed in nuclear power plants that transmit electrical power, control and instrument signals. The failure criteria of various power and control cables coated with fire retardant coating at three different coating thicknesses (~0.5 mm, 1.0 mm & 1.5 mm) were studied under direct flame test using Container Fire Test Facility (CFTF) based on standard tests for bare cables. A direct flame fire test was conducted for 10 min with an LPG ribbon burner rated at ten by fixing the cable samples in a vertical cable track. Inner sheath temperature was measured until ambient conditions were achieved by natural convection. The cables are visually evaluated for damage and the mass loss percentage. Cable functionality is ascertained by checking for electrical continuity for each sample. The thickness of cable coating on fire exposure is also studied by comparing the transient variation of inner sheath temperature along the Cable length. This study also evaluated the adequacy of fire-retardant coating on cables used for safety-critical equipment in nuclear power plants.

내화용 오일붐의 내화성에 대한 실험적 연구 (An Experimental Study on Fire-Resistant Boom)

  • 유정석;성홍근;오준헌
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제3권2호
    • /
    • pp.25-32
    • /
    • 2000
  • 내화용 오일붐은 해상누유사고시 누유현장소각기술에 있어서 핵심적인 방제장비이다. 본 논문에서는 내화용 오일붐의 성능평가기법으로 전기로시험과 수조시험을 제안하였다. 전기로시험에는 내화용 재질의 내화성을 평가하며, 수조시험에서는 실제 현장소각시에 화염에 노출된 내화용 오일붐의 상태를 최대한 모사하였다. 수조시험장비는 유조, 내화용 오일붐 모형, 연소가스 흡입을 위한 후드, 소각로와 온도계 등으로 구성된다. 본 연구에서 개발된 내화용 오일붐에 대하여 성능평가를 수행한 결과, 화염온도 800℃에 대하여 견딜 수 있음을 확인할 수 있었다. 본 연구의 성능평가기법이 실제 해상에서 사용할 수 있는 내화용 오일붐에 대하여 적용할 수 있기 위해서는 보다 더 높은 측도의 시험시설 및 장시간의 실험이 요구된다.

  • PDF

주요 사례를 통한 재래시장의 전기화재 위험성 및 안전대책에 관한 연구 (A Study on Electric Fire Risk and Safety Measures in Traditional Markets through the Significant Fire Events)

  • 최승복;이창우;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.122-127
    • /
    • 2010
  • 재래시장은 전국적으로 약 1,550여개에 달하며 이들 대부분은 임대형식으로 운영되고 있기 때문에 영세하고 공간 또한 협소한 상태이며 다양한 종류의 전기제품이 내재되어 있기 때문에 화재 위험성이 높다. 근래에 들어 국가적 차원에서 재래시장의 현대화를 독려.지원하고 있지만 현대화 시설이 완료된 곳은 약 50%에 불과하다. 또한 현대화 시설중 전기설비는 '전기설비 기술의 판단기준'에 부합되지 못하여 화재위험성이 상존하고 있다. 본 연구에서는 현대화 시설이 완료된 곳과 그렇지 못한 재래시장의 전기설비의 설치와 사용 실태를 알아보고 이에 따른 전기 화재 위험성을 분석하였다.

환기량 조건이 열차 화재 성장에 미치는 영향성에 대한 FDS 화재 시뮬레이션 (Numerical study of the Effect of Ventilation Condition on Rolling Stock Fire Growth through the FDS Simulation)

  • 양성진;이창덕;오지은;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.124-132
    • /
    • 2010
  • To predict and analyze the rolling stock's fire growth is considered not only important factor in estimating hazard analysis of rolling stock, but also a primary factor in aspect of a rail load facility. Because it's could be regarded as a ignition source in risk assesment for the facility i.e. tunnel and station. However, currently, standardized method to predict and analyze the fire growth has not been completed yet. it is due to the fact that fire growth is not only depended on thermal property of interior materials, but also is affected dominantly by various factors such as ignition source (characterized by location, duration, and intensity), train running condition and in/exterior ventilation condition. Especially, ventilation condition is one of the most effective factor to affect fire growth in compartment space as noticed by under-ventilation fire condition. In this study, the effect of each ventilation condition on fire growth and load were examined through the numerical method through FDS (Fire Dynamics Simulator).

  • PDF

조선 후기 도서 지역의 봉수 연구 - 강화도와 제주도를 중심으로 - (A Study on the Bongsu (Beacon Fire Station) in the late Joseon Dynasty - Focusing on Ganghwado and Jeju Islands -)

  • 오신일;이왕훈;김영재
    • 건축역사연구
    • /
    • 제32권1호
    • /
    • pp.35-45
    • /
    • 2023
  • Bongsu(Beacon Fire Station) is a facility that sends signals with fire and smoke and has been used in Korea since the Three Kingdoms period. This facility was installed to know the north and south crises. This trend continues until the Joseon Dynasty, and it has been somewhat completed in the 17th century. In previous studies, beacon fire was identified mainly from the border area to Hanyang. Based on this, it was classified into Gyeongbongsu, Yeonbyeonbongsu, and Naejibongsu. However, it is difficult to define the characteristics of beacon fire in coastal areas only with this classification. In the case of beacon fire in island areas, there was a tendency to value communication connection within the region rather than connection with the capital. As a case analysis for this, an academic review was conducted with the cases of Ganghwa Island and Jeju Island. As a result, it was confirmed that the role and character of the beacon vary depending on the defense system and the physical distance from the land, even if it has the topographical commonality of the same island.

아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석 (An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building)

  • 손주달;공하성
    • 대한안전경영과학회지
    • /
    • 제22권1호
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

도시 재해위험도 평가 모형 연구 - 화재, 시설, 피난위험도 중심의 청주시 사례 - (Empirical Application for the Urban Disaster Risk Assessment : Fire, Facility and Escape Cases in Cheongju City)

  • 황희연;백기영;박병호;이만형;황재훈;류을렬;김태환
    • 한국방재학회 논문집
    • /
    • 제1권2호
    • /
    • pp.123-137
    • /
    • 2001
  • 본 연구는 우리나라의 도시재해의 특성과 자료확보 가능성을 기반으로 청주를 사례로 화재, 시설, 피난위험도에 한정하여 재해위험도 평가모형을 제시하고 있다. 평가기준에 있어 동별 기준으로 화재위험도는 화재발생건수와 피해액을 기준으로 하고 있으며, 시설위험도의 경우 중점관리시설의 개소 수와 관리등급을 기준으로 하고 있고, 피난위험도는 지목별 면적과 지목별 가중치로 모형을 설정하였다. 청주시에 대한 모형 적용 결과 화재위험도는 불량주거지역과 생활편익시설이 집중되어 있는 중심 상업지역내의 시가화구역이 상대적으로 높게 나타났으며, 반대로 시설위험도와 피난위험도는 신흥 아파트 밀집지역과 구주거지역 모두가 높게 나타났다 종합위험도에 있어서는 중심상업지역과 그 주변밀집주거지역에서 높은 점수를 나타내는 것으로 판명되었다.

  • PDF

사회복지시설의 유형에 따른 안전관리의 차이에 관한 연구 (A Study on the Safety Management Differences According to Social Welfare Facility Type)

  • 신효진;공하성
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.89-97
    • /
    • 2014
  • 이 연구는 사회복지시설의 증가로 인하여 사회복지시설의 안전관리의 중요성이 대두되고 있는 현시점에서 사회복지시설의 안전관리인식, 안전관리실태, 시설구조 및 설비인식에 대한 분석을 하였다. 총 12개 사회복지시설에 소속된 204명의 시설이용자와 시설관리운영자를 대상으로 설문조사를 실시하였으며, 사회복지시설의 유형에 따른 의미 있는 차이를 알아보기 위해 평균차이검증(t-test)과 일원분산분석(ANOVA)을 실시하였다. 분석결과는 다음과 같다. 첫째 안전관리인식, 안전관리실태, 그리고 시설구조 및 설비인식에 있어서 시설관리운영직원의 인식수준이 시설이용자보다 통계적으로 유의하게 높은 것으로 나타났다. 둘째, 시설유형에 따른 안전관리분석 결과는 건강가정지원센터 관리자 및 사용자의 안전 인식수준이 안전관리인식, 안전관리실태, 시설구조 및 설비인식의 모든 분야에 있어서 다른 사회복지시설의 응답자보다 유의하게 낮게 나타났다. 셋째, 6~10년 미만 시설의 응답자 보다 10년 이상 된 시설 응답자의 안전관리인식과 시설구조 및 설비에 대한 인식이 높게 나타났다. 넷째, 건물높이에 따른 안전인식에 있어서는 3층과 4층이 1층보다 유의하게 높게 나타났다. 마지막으로 바닥면적과 안전인식과의 관계를 살펴보면, $400m^2$ 미만 또는 $600m^2$ 이상의 바닥면적을 가진 응답자들의 안전인식이 400 이상${\sim}600m^2$ 미만 응답자들보다 유의하게 높게 나타났다.

Radio Frequency Based Emergency Exit Node Technology

  • Choi, Youngwoo;Kim, Dong Kyoo;Kang, Do Wook;Choi, Wan Sik
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제2권1호
    • /
    • pp.91-100
    • /
    • 2013
  • This paper introduces an indoor sensor fusion wireless communication device which provides the Location Based Service (LBS) using fire prevention facility. The proposed system can provide information in real time by optimizing the hardware of Wi-Fi technology. The proposed system can be applied to a fire prevention facility (i.e., emergency exit) and provide information such as escape way, emergency exit location, and accident alarm to smart phone users, dedicated terminal holders, or other related organizations including guardians, which makes them respond instantly with lifesaving, emergency mobilization, etc. Also, the proposed system can be used as a composite fire detection sensor node with additional fire and motion detect sensors.