• Title/Summary/Keyword: Fire extinguishing performance

Search Result 131, Processing Time 0.021 seconds

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.

Evaluation of Design Fire Curves for Single Combustibles in a Cinema Complex (복합영상관 단일 가연물의 디자인 화재곡선 평가)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong;Oh, Chang Bo;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.18-27
    • /
    • 2020
  • An actual fire test was performed on single combustibles placed in a local cinema complex, and quantitative differences in the maximum heat release rate (HRR) and fire growth rate were investigated based on the design fire curve methods (i.e., the general and 2-stage methods). In terms of combustible use and fire load, a total of 12 combustibles were selected, classified into cinema lounge and movie theater. It was found that the maximum HRR and fire growth rate determined using the two-stage method were quantitatively different from those of the general method. The application of the two-stage method, which can be used to determine the fire growth rate of the initial fire stage more precisely, could be useful in accurately predicting the activation time of fire detectors and fire-extinguishing facilities, as well as the available safe egress time (ASET) and required safe egress time (RSET).

A Study on Fire Protection in Nuclear Power Plants and Application of the Code and Standards for Fire Protection Systems (원자력발전소 화재방호와 소방시설 기술기준 적용에 대한 고찰)

  • Kim, Wee-Kyong;Jeong, Kee-Sin
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.38-44
    • /
    • 2012
  • The purpose of fire protection for the nuclear power plants (NPPs) is to ensure safe shutdown state of the reactor, to minimize the release of radioactive materials to the environment, to provide physical safety of the on-site personnel, and to limit the property damage. Fire protection and extinguishing equipments are one of the important protection measures based on the defense-in-depth concept, which can promptly detect and control and extinguish those fires that do occur, thereby limiting fire damage. However, a separate evaluation process might be additionally necessary for the construction permit and operating license because the fire protection laws of the NEMA for installation standards of the fire protection systems is not fully characterized for the NPPs. It is also not easy to implement the regulations such as the performance based design concept for fire protection system of the NPPs which are characterized for a relatively low density of employee. This study suggests a guideline for the improvement of the technical standards for fire protection systems of the NPPs by evaluating the fundamental problems drawn by reviewing laws and regulatory guides relevant to fire protection and by evaluating the applicability of the KEPIC FPN in domestic nuclear power plants.

A Study on Performance-based Seismic Design Method of Fire Extinguishing Pipe System (소화설비 배관의 성능위주 내진설계 방법에 관한 연구)

  • Lee, Jae-Ou;Kim, Hong-Kyung;Cho, Soon-Bong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.86-94
    • /
    • 2017
  • In the present study, a Cook Book method and a Static System Analysis method were compared with each other on the basis of a seismic design criteria of fire-fighting facilities and analyzed. The Cook Book method is analyzed by dividing a pipeline in each same section. In this method, a stress analysis is not possible except for the section analyzed in such a way that a brace is designed according to the weight of pipe, water and pipe fitting. To the contrary, in case of the Static System Analysis method, the stress analysis for the whole pipeline can be performed because the whole pipeline is regarded as a single structure. For the fatal stress values locally generated, it is necessary to actively perform a pipeline analysis by installing a device capable of locally relieving the stress of the pipeline. In Korea, only the Cook Book method is provided as the seismic design criteria of fire-fighting facilities, which causes many problems with diversification of seismic design. Thus, it is necessary to apply the seismic design method of the pipeline by using various kinds of engineered Static System Analysis methods.

A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate (방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구)

  • Oh, Chan-Wook;Oh, Ryun-Seok;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.56-62
    • /
    • 2019
  • A sprinkler is a fire extinguishing equipment installed in a protected area where a detector or head detects a fire and automatically puts out the fire. However, the Ministry of Land, Infrastructure and Transport's "Regulations on Building Evacuation and Fire Protection Standards, etc." stipulate that fire compartment area should be reduced to three times by installing sprinkler facilities in the case of factories and warehouses. In this study, fire hazard was analyzed for a real PCB factory which mitigated the fire protection zone by sprinkler installation, and the head opening characteristics of sprinkler facilities through computer simulation, installation standards of sprinkler facilities, thermal performance, operating range, and the amount of water sprayed to identify the problems of operation of sprinkler facilities in case of fire, and to suggest the grounds such as required sprinkling flow rate for system improvement.

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.

A Study on the Fire Characteristics of Palletized Unit-Load Commodities on Racks (랙크 내 파렛트단위 적재물품의 화재특성에 관한 연구)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.23-30
    • /
    • 2016
  • A fire extinguishing system for a rack warehouse was recently designed, which only consider the gross area and number of stories. However, the design of such a system should take into account not only the planar structuree, but also the elevation perspectives due to its vertical structure. Moreover, the fire load of the commodities palletized on the racks should be considered, in order to design a performance-based fire safety system that is appropriate for these environmental conditions. For this reason, this study analyzed the fire characteristics of the commodities palletized on the racks (pallet + the commodities in a box unit + vinyl packing material), taking into consideration the results of a field investigation conducted in Korea, as well as the Hazard Classifications of Commodities used in other countries. Through this analysis, the heat release rate (HRR) and smoke production rate (SPR) were derived.

Sprinkler Layout Optimization Based on Fire Simulation and Mathematical Programming including Installation and Damage Costs (설치비와 피해액의 정형화를 통한 화재 시뮬레이션 및 수리계획법에 기반을 한 스프링클러의 배치 최적화)

  • Lee, Ki-Jun;Shin, Young-Sup T.;Hong, Gi-Hoon;Joo, Ki-Don;Shin, Dong-Il;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.52-59
    • /
    • 2012
  • The sprinkler system is regarded as the most effective fire extinguishing system. In this study, we proposed a sprinkler layout optimization framework based on fire simulation and mathematical programming. As a case study, the target space in the form of ordinary residence was set up with the size of $5.2m(L){\times}5.4m(W){\times}2.4m(H)$, and we constructed the fire scenario that polyurethane couch was ignited through carelessness. And we simulated and analyzed fire speed, temperature change and heat release rate according to the type and number of sprinklers installed. Through the formulation of installation and damage costs depending on sprinklers, the sprinkler layout showing optimal performance was resulted from mathematical programming.

Effect of Nozzle Shape and Injection Pressure on Performance of Hybrid Nozzle (노즐 형상 및 분사 압력이 하이브리드 노즐 성능에 미치는 영향 연구)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.74-79
    • /
    • 2017
  • The fire extinguishing performance of hybrid nozzle systems is improved by injecting an extinguishing agent concentrically into the target site and, in this study, water mist is used as a water curtain to confine the droplets of the agent. In this study, we numerically investigated the effect of the foundation angle and injection pressure on the performance of a hybrid nozzle by evaluating the mean radius of the volume fractions of the agent and water mists. An experiment involving a water mist nozzle was carried out to validate the numerical method and then the droplet behaviors, e.g., stochastic collision, coalescence and breakup, were calculated with 2-way interaction Discrete Particle Modeling (DPM) in the steady state for the hybrid nozzle system. The mean radius of the water mists increased by about 40 %, whereas that of the agent decreased by about 21 %, when the injection pressure was increased from 30 bar to 60 bar. In addition, the mean radius of the agent increased by about 24 % as the foundation angle of the hybrid nozzle head increased from $30^{\circ}$ to $60^{\circ}$. As a result, it can be inferred that the injection angle and pressure are important factors for hybrid water mist designs.

A study on design and performance test of fire door with high endurance performance in submarine tunnel (고내구성능을 갖는 해저터널 방화문 설계방안 및 성능시험 연구)

  • Park, Sang-Heon;Hwang, Ju-Hwan;Choi, Young-Hwan;An, Sung-Joo;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.331-346
    • /
    • 2018
  • In the tunnel of domestic high - speed railway, the main fire - fighting facility, fire - extinguishing passageway, is installed. However, due to the high pressure of the high - speed train, frequent breakage and maintenance are caused by strong shock and long - term vibration. In order to solve these problems, it is necessary to improve the fire door, but in Korea, it is installed by submitting a certificate by simple KS F 2296 performance test. At present, it is developed as a simple test certification by producing a real scale fireproof door without the theoretical examination in advance, so that a high cost for improvement is occurring in Korea. Therefore, through this study, structural analysis study which can preliminary structure review was carried out in order to design the refuge connection passage fire door and to improve the performance improvement. In order to secure the reliability of the result value, the official authentication test (KS F 2296) were compared.