• Title/Summary/Keyword: Fire escape simulation

Search Result 52, Processing Time 0.024 seconds

Numerical Simulation of Smoke Ventilation in Rescue Route and Cross Passage of Railroad Tunnel (철도터널 화재시 연결통로 및 대피로 제연을 위한 수치해석 연구)

  • Yang, Sung-Jin;Hur, Nahm-Keon;Ryou, Hong-Sun;Kim, Dong-Hyeon;Jang, Yong-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • A transient 3-D numerical simulation was performed to analyze the fire safety in a railway tunnel equipped with a mechanical ventilation system. The behavior of pollutants was studied for the emergency operation mode of ventilation system in case of fire in the center of the rescue station and near the escape route. Various schemes of escape route construction for connection angle($45^{\circ}$, $90^{\circ}$, 135^{\circ}$) and slope($10^{\circ}$) were evaluated for the ventilation efficiency in the fire near the escape route. From the results, it was shown that the mode of the ventilation fan operation which pressurizes the tunnel not under the fire and ventilates the smoke from the tunnel under the fire is most effective for the smoke control in the tunnel in case of the fire occurrence. It was also shown that the blowing of jet fan from the rescue tunnel to the main tunnel should be in the same direction as the flow direction in the main tunnel arising from the traffic and the buoyancy.

Development of Post-Processor for Fire Simulation (화재 시뮬레이션을 위한 후처리장치 개발)

  • Hur S.;Chang J.;Hur N.
    • Journal of computational fluids engineering
    • /
    • v.7 no.3
    • /
    • pp.27-34
    • /
    • 2002
  • When caught in a fire inside a building or a tunnel the generated smoke is the main cause of the bad visibility, which makes it difficult for a person to find escape route. Therefore of the fire simulation it is required to visualize the simulated results of smoke realistically form a viewpoint of a person caught in a fire. In the present study, developed is a CFD post-processor which can visualize the object through smoke from the results of CFD fire simulation. Examples of some applications of the program are shown in the paper.

Study on the Analysis of Fire Propagation in Road Tunnels (도로터널의 화염전파해석에 관한 연구)

  • 권용일;유지오;이동호;권순석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.616-622
    • /
    • 2000
  • This paper concerns the application of smoke and fire spread to road tunnel fire problems. When a road tunnel is on fire. a fire protection system of road tunnel have to offer an adequate escape space to human. Therefore, this study carried out a simulation for predicting a spreading path of smoke and fire. The evolution of the flow field is simulated with the low Reynolds number k-$\varepsilon$ turbulent model and SIMPLE algorithm based on the finite volume method.

  • PDF

A Study for Evacuation Assistance to Vulnerable People by MAS Based Evacuation Simulation (MAS 기반 대피시뮬레이션을 활용한 안전약자 대피지원 개선방안 연구)

  • Jung, Tae Ho;Park, Sang Hyun;Jang, Jae Soon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.121-127
    • /
    • 2017
  • Recently, many patients in a hospital are threatened life by fire disaster. Because many patients like vulnerable people have more evacuation problem than ordinary person. So a patient who can escape by oneself with walking assistance device like crutches or wheelchair and another patient who can't escape by oneself are should be supported safety technologies and service. Earlier research of 'hospital evacuation' led by actual experiments or computer evacuation simulation. Actual experiment is effective to gain credibility of result but it is difficult for patients to experiment repeatedly and it requires consideration for spatial problem and economic problems. Although computer evacuation simulation have been used to solve these problems, almost have concluded only results based on velocity without evacuation device. In this study, evacuation results with support device application or not are analysed used by computer evacuation simulation based on MAS(Multi Agent System). As a result, it is drawn through proof of efficiency of evacuation device in the vertical space like stairs that can improve the evacuation plan for vulnerable people in the hospital.

A Study of Proper Escape way interval by QRA on Single bored double track tunnel (정량적 위험도 분석을 이용한 복선철도터널에서의 적정 대피통로 간격 산정을 위한 연구)

  • Roh, Byoung-Kuk;Lee, Ho-Suk;Song, Myung-Kyu;Choo, Seok-Yeon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.371-376
    • /
    • 2007
  • This paper describes a study to determine proper escape way interval for the design phase of single bored double track tunnel. Among many methods which determine escape way interval, we choose a QRA(Quantitative Risk Analysis) method. But a different method must be chosen differ from other country because of special design situation of Korea. So, it is necessary to develop a method which considers a special design condition of Korea. Because fire accidents of railway tunnel are a rare event, simulated situation can be produced by CFD simulation and evacuation analysis simulation. However, it is generally difficult to estimate of fatalities from these methods, so a concept of FED is introduced to estimate of fatalities. Quantification process provides effective results for practical design stage and the result were employed in design.

  • PDF

RSET Analysis According to the Width of Escape Routes in Large Supermarkets (대형마트의 피난로 폭에 따른 RSET 분석)

  • Boohyun Baek;Hongsang Lee;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.29-38
    • /
    • 2024
  • The purpose of this study is to use an evacuation simulation program to measure the change in evacuation time according to the width of the evacuation route due to the installation of an intermediate sales counter and the placement of a shopping cart between the sales counters of a large supermarket and to analyze the results. Currently, the "Distribution Industry Development Act" does not regulate the size and installation method of intermediate sales counters installed between sales counters that serve as practical evacuation routes in the event of a fire at a large supermarket, the size of shopping carts, etc. Considering this, we set evacuation route widths of 40, 50, 60, 70, 80, and 100 cm and compared and analyzed evacuation times according to various variables in the facility space. As a result of the experiment, as the width of the evacuation route was expanded, there was a significant difference in the evacuation time, from a maximum of 468.3 seconds to a minimum of 320.8 seconds. Considering the safety of evacuees in large supermarkets used by many people, it is time to regulate the size of intermediate sales stands installed between sales counters in large supermarkets and shopping carts that can become obstacles in an emergency.

A Study on Escape Safety Assessment of High-Rise Office Buildings for Security Plans (경호경비계획을 위한 사무용 고층건축물의 피난안전성평가에 관한 연구)

  • Park, Nam-Kwun;Lee, Young-Ju;Yoon, Myong-O
    • Korean Security Journal
    • /
    • no.28
    • /
    • pp.57-77
    • /
    • 2011
  • Recently, property and life loss is increasing internally and externally, due to fire spread in high-rise buildings which results from a variety of disasters like fire and terror. In this study, therefore, an evacuation simulation was performed to predict escape behaviors of occupants and assess escape safety in high-rise office buildings after setting up each scenario, as part of safety measures for high-rise buildings. Based on the results and data obtained, escape safety was assessed, finally. The results and suggestions of this study are as follows. Firstly, most of the present researches on high-rise building and multiple-use facilities are weighted towards qualitative perspectives. It is, therefore, considered that we have to establish concrete, practical, systematical and rational safety measures to minimize damages in dangerous situations, by analyzing security plans for high-rise buildings in depth and preparing for those situations from various angles. Secondly, setting up evacuation sections in security plans for high-rise buildings is an important factor which influences refuge. Thirdly, in relation to security plans for high-rise buildings, it is possible to reduce the entire time for escape, by setting up escape exits of each floor in consideration of a simultaneous evacuation situation.

  • PDF

A Study on the Evaluation Method of the Building Safety Performance and the Prediction of Occupants′ Egress Behavior during Building Fires with Computer Simulation (컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가방법에 관한 연구(II))

  • 최원령;이경회
    • Fire Science and Engineering
    • /
    • v.3 no.2
    • /
    • pp.11-19
    • /
    • 1989
  • In this study, the independent variables are the floor plan configulation. The dependent variables are the occupant's egress behavior, especially spatial movement pattern, and life - safety performance of building. Fire events were simulated on single story of office building. Simulation run for allowable secaping thime(180 seconds) arbitrarily selected, and involved 48 occupants. The major findings Pre as follows. 1) Computer simulation model suggested in this study can be used as the Preoccupancy evaluation method of the life-safety performance for architectural design based on prediction of occupants' egress behavior in the levels of validity and sensitivity, 2) Sucess or failure in occupants' escape is determined by decreasing walking speed caused by jamming at exits or over crowded corridor, and increasing route length caused by running about in confusion at each subdivision and corridor. 3) In floor plan configuration which safe areas located at the extreme ends of the corridor, cellular floor planning have to be avoided preventing jamming and running about in confusion at overcrowded corridor.

  • PDF

ANALYSIS OF FIRE CHARACTERISTICS IN APARTMENT BUILDING THROUGH FULL SCALE EXPERIMENT AND ZONE MODEL SIMULATION

  • Yoon, Myong-O;Park, Jin-Kook;Kim, Choong-Ik;Ryou, Hong-Sun;Kim, Jin-Gon;Kim, Myung-Bae;Choi, Jun-Seok;Kim, Kwang-Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.413-422
    • /
    • 1997
  • Fire characteristics of a typical apartment building in Korea was studied through full scale experiment and zone model simulation. The fire was ignited at the living room and allowed to spread to other parts of a single unit in a five storied apartment building. Various data including temperatures, species concentrations, and images were collected in the experiment. A zone model(CFAST) was used to analyze the same apartment building that represents the average households in Korea. The results were compared with a full scale experiments. While CFAST allows one compartment involved with fire, the experiment allowed the fire to spread to other compartments. Therefore, the comparison between experimental data and Zone-Model data is valid until the living-room fire spread to other parts of the apartment. Flashover occurred at approximately 380 seconds in a fire experiment, and at approximately 420 seconds in Zone-Model. Based on all of data between experimental data and Zone-Model data, it is concluded that the safe escape time is about 250 seconds.

  • PDF

Construction of the Smoke Exhaust System and Its Applicability by the Fire Model Test for a Bidirectional Tunnel (대면교행터널에서 배연시스템의 구축과 화재모형실험에 의한 적정성 평가)

  • Lee Sang-Eun;Lee Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.15 no.6 s.59
    • /
    • pp.452-461
    • /
    • 2005
  • In a bidirectional tunnel, the accident rate is 1.5 times as high as that of one directional tunnel , the risk of a fire is increased. On fire, there is a problem that the jet fan should not be operated until completion of refuge. To be special, as the great damages occur owing to the expansion of smoke in long tunnels, there is a need to minimize fatality by constructing cross passage and smoke removal system. This study aims at verifying the efficiency of smoke exhaust system through fire propagation simulation as well as scale model test. The results show that completion of escape through emergency exit requires 335 seconds, while addition of smoke exhaust system reduce the escape time to 185 seconds. Also, near the fire source temperature decreased by about $60^{\circ}C$. Without the exhaust system, fire propagation speed was in the range of 0.36 and 0.82 m/s, and it dropped to $0.27\~0.58\;m/s$ with the exhaust system on. Taking into account the escape speed of tunnel users, usually $0.7\~1.0\;m/s$, the emergency exit built every 150m is sufficient for the safe egress. The ultimate goal of this study is to provide fundamental information for the smoke exhaust system in bidirectional tunnels.