• Title/Summary/Keyword: Fire equipment manager

Search Result 9, Processing Time 0.025 seconds

A Study on the Reformation of Certified Fire Fighting Specialists - Focused on Fire Protection System Managers - (소방전문자격사제도의 개선에 관한 연구 - 소방시설관리사를 중심으로 -)

  • Oh, Hyeong-Geun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.21-28
    • /
    • 2006
  • This research analyzed the operational status of fire protection system managers who execute self inspection of the fire equipment in the specific fire protection facilities and presented the improvement scheme. Being made up inquiry for job environment, institutional environment, and operational environment for the subject of fire protection system managers who execute self inspection to complement the fire equipment inspection by city public fire protection service, the issues of the operational status of the institution of fire protection system managers were positively understood. The research result showed the conflict among building owner, fire equipment inspector, and fire protection system manager was existed due to the legal and institutional inertia to the self inspection, so it is judged that mutual complementary and cooperative relation should be established.

The Present Situation and Preventive Measure of the Fire in the Cattle Shelter -Based on Jeonbuk Province- (축사 화재의 현황과 그 방지 대책 -전라북도를 중심으로-)

  • Jeng, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.81-87
    • /
    • 2007
  • The cattle shelters have been badly damaged by the recently large fires. so the reconstruction of the damaged shelter is very difficult. In the light of the seriousness of the fire like that, the preventive plan for the cattle shed should be thoroughly established. The preventive measure which the fire department performs presently is limited to the stopping the fire before it starts. More than anything else, The men who operate and manage the cattle shelters must know what to do. The written plan will assist them. To begin with, The fire authority should clearly specify how cattle should be protected from any outbreak of fire. Clear access to each fire shed is very important to protect the cattle safely. The manager of the cattle shelter should get ready for the fire defense equipment. Most fires of the cattle shelters are due to electricity faults. These renovations should be performed and checked immediately. Therefore, The manager should be ready assist fire chief or the professional organization to prevent the electricity fire. Fire Safety education should be planned for the owner and staff so all should know what is expected in case of a fire. The Fire Department will check the access road, the equipment available and an announced fire drills should take place every year in the cattle shelter. The Fire Department should check the access road, equipment for preventing fires and staff training each year.

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.

A Study on the Effective Method of Fire Safety Management of Geriatric Hospitals (요양병원 소방안전관리의 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.83-88
    • /
    • 2016
  • Currently many geriatric hospitals have been built in Korea because increasing aging rapidly. However the increasing geriatric hospitals make the increasing safety accidents. Therefore this study is conducted by survey and face-to-face talk with the fire safety managers for analyzing safety problem of geriatric hospitals which number is twelve among 15 geriatric hospitals in the north of Chung-buk area. The result of this study is that geriatric hospitals are very old. Fire safety managers holding the fire safety license are a level 2 issued by the Korea Fire Safety Association(KFSA). And the fire safety inspection ability of them is normal (58%). Furthermore a fire safety budget ratio is 83% (A little) in the company yearly budget. And ratio having the fire inspection equipment in the building is 42% (A little) and 33% (Nothing). Satisfaction ratio of their duty is 66% and they also get stress from heavy duty and heavy responsibility. In conclusion, CEO needs to invest and interest the improvement of job performance, satisfaction ratio and fire safety facility. Also government needs the improvement of system to support and supervise the fire safety of geriatric hospitals consistently.

The Relationship between Job Satisfaction and Turnover Intention among Fire Protection System Management Workers (소방시설관리업 종사자의 직무만족과 이직의도와의 관계)

  • Lim, Kyoung-Yeon;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.142-151
    • /
    • 2019
  • This study examined job satisfaction among fire protection system management workers in the fire industry and analyzed how job satisfaction affects turnover intention. The results revealed that, among the control variables, including age, rank, academic background, payment, total career, license, and tasks, significant differences in job satisfaction were found in the tasks between groups, while no significant differences in turnover were found in any control variable between groups. Additionally, the results revealed that, among the lower variables of job satisfaction, increased satisfaction with payment and organizational system affected the degree of turnover intention, while work and promotion did not. These results are to be used as data for human management of technicians and for creating alternatives. Future studies are required to establish a reasonable task rotation cycle for raising job satisfaction, to examine the current status of low-cost orders and countermeasures, and to analyze the direction of development of fire protection system management business.

Empirical Study to Strengthen the Disaster Management of Wooden Cultural Heritage - Focused on Concept and Range of Cultural Heritage Disaster Management and Investigation of On-site Manager (목조문화재의 안전관리 강화를 위한 실증적 연구 - 문화재 안전관리의 개념과 범주 및 현장 관리자 의식조사를 중심으로 -)

  • Lim, Suhng-bin;Ryu, Ho-cheol
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.2
    • /
    • pp.96-113
    • /
    • 2013
  • The concept of disaster management of cultural heritage is not clearly established and the range and type of it is not organized yet. Also, there is an ever-present danger in the field control because there is no system that can provide safety of cultural heritage from various dangerous factors. Concretely, institutionally, the regulation of disaster management of cultural heritage remains limited and there are not enough reasonableness in installation and management of fire-fighting equipment and safety equipment. Also, we need to take an action to secure the safety of cultural heritage from its surroundings. In this research, we setup the concept, type and criteria for disaster management of cultural heritage to overcome limitations and problems of management of cultural heritage. In addition, in order to raise the level of disaster management of cultural heritage, this research proposes direction to reinforce the disaster management of cultural heritage by investigating and analyzing consciousness of security guards and fire-fighting officers.

A Study on the Domestic Fireworks System (불꽃놀이 시스템의 국산화에 대한 연구)

  • Choi, Joon-Kee;Son, Moo-Yeol;Lee, Jong-Kwang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Fireworks are used in our country, most of U.S. equipment and software systems are old and outdated technology. If the Fireworks receives a signal, then the start of the pre-placed as the signal proceeds to the middle of a problem with the site manager directly turn off the power and turn on again. Manager, where it should be handled directly. So, in this paper, we researched a domestically developed technology to escape the reality that relies on foreign technology. Our technology should be suited the convenience, reliability and lower cost. This technology can generate revenue from overseas.

Multi-family Residential Construction Management Practice in the U.S.

  • Cho, Namho
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1254-1254
    • /
    • 2022
  • The Multi-family Residential is one of the most famous building types for a rental property in the US. Often times it includes multiple residential buildings and some amenity facilities, including a clubhouse or leasing office, swimming pool, dog park, and garages. Since the building type is built for rental purposes, the construction planning is phased and it makes the project complicated. Detailed planning and execution are important for successful construction management. This paper provides some management practices that are applied to one of the multi-family residential construction projects in Phoenix, AZ. The Front End Planning (FEP) process performed by both owner and contractor is the first key to a successful construction project. Specifically, the early review of phased turnover strategy, grading, fire/Americans with Disabilities Act (ADA) compliance, and Mechanical/ Electricity/Plumbing/Technology (MEPT) will provide absolute benefit to the project. Second, using a scheduling method to control short-term schedules and long-term can provide the ability to manage the issues with agility. Third, material delivery and procurement dominate the both project schedule and cost. With this COVID-19 circumstance, it is hard to expect the material, equipment, and labor forces to be delivered on time with the contracted price. Managing floats are more than important to managing construction productivity. Risk management should work to share the risks fairly. Lastly, turnover is directly linked with the profit of the project for both owner and contractor. The communication between the owner and contractor to re-schedule the proper turnover schedule is important for the phased construction project.

  • PDF

A Study on the Identification of Hazardous Factors and Prevention of Accident in Old Boilers (노후보일러 유해인자 발굴 및 사고예방에 관한 연구)

  • Sa, Min-Hyung;Woo, In-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.1-9
    • /
    • 2019
  • Large-scale industrial boilers operating at high temperature and high pressure, have a large amount of water, and a large amount of energy is released at the time of explosion. Currently, most industrial boilers use gas fuel such as LNG and LPG, etc. and fuel exists in the same space as equipment, so there is a high possibility of secondary damage such as fire or explosion in the event of a boiler accident. Both special care and management are required to operate the very dangerous equipment that causes casualty 2.51 per accident. For boilers of a certain size or more, the Korea Energy Agency conducts inspections in accordance with the Energy Usage Rationalization Act, KS, and public notice of the Ministry of Industry, Trade and Resources. In this research, based on the results of the inspection, the hazard factorss are configured, and a questionnaire is conducted to the inspector, the equipment manager, the maintenance person, and the person in charge of the manufacturer. We analyzed the results by using AHP (Analytic Hierarchy Process). As a result of analysis, generally recognized hazard factorss are not good management, measurement failure, specification failure, water leak, leak analysis, but connection, welding, scale, and corrosion, etc. are relatively less important. It is judged that the adverse factors that are recognized to be highly important among all groups and careers are already well managed, but less important and adverse factors should be well managed to ensure that the safe usage of the boiler.