• Title/Summary/Keyword: Fire effluent

Search Result 11, Processing Time 0.02 seconds

Toxicity Evaluation of Effluent Gases from a Residental Fire by Rats (연립 주택 화재시 유독가스 방출 특성과 Rats를 이용한 독성평가)

  • Kim, Hong;Kang, Young-Goo;Kim, Dong-Hyun;Jung, Ki-Chang;Lee, Chang-Seop;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.12-15
    • /
    • 2002
  • It has long been recognized that exposure to fire-induced toxic gases is a fatal hazard confront-ing people in fires. In this study, an indoor fire experiment was conducted in an unoccupied residential building located in An-san city, Kyoung-gi province, and the composition of effluent gases, which include CO, $CO_2$, $O_2$, $SO_2$, NO and $NO_2$, were measured by a gas analyzer. A group of lab rats were exposed to the toxic gases released from fire, and the blood samples of the rats were gathered every 2 minutes. A toxicity evaluation was conducted by analyzing the concentrations of Glucose, AST(GOT), ALT(GPT), CBC Count and CO(carboxy)-Hb in the blood samples. Shown from the analysis is the does-response relationship between the CO concentration that rats were exposed to and the CO-Hb concentration in rat blood.

A Research of Grain Size Analysis of Particulate Matter in Fire Effluent (연소 생성물 내 입자상 물질의 입도에 관한 연구)

  • Kim, Sung-Soo;Choi, Seo-Yeon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.8-12
    • /
    • 2014
  • Interior finishing materials using noncombustible were regulated by the building codes to prevent the spread of fire and protect occupants. The average deed of stopping time of experimental mouse exposing combustion gas were measured by KS F 2271 gas toxicity test. At that time, The average deed of stopping time under 9 minutes were judged a inconsistence. This experiment method has limit to find out a cause of toxicity effect factor. In this study, particle size analysis were performed for investigate a major factor.

A Research of Risk Assessment for Urethane Fire Based on Fire Toxicity (연소 독성 기반 우레탄 화재의 위험성 평가 연구)

  • Kim, Sung-Soo;Cho, Nam-Wook;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • Fire in the risk management subject belongs to high risk disaster which accompanies personnel and materiel loss. So, management of disaster and safety is required to include fire prevention activities, fire risk prediction and investment of safety management expense. Combustion toxicity is required by gas toxicity test (KS F 2271), to minimize human damage. In this study, gas toxicity test were experimented with regard to urethane sample (Depth 5~25 mm) to obtain basic data. Fire effluent exposing to experimental animal were analyzed by FT-IR (Fourier transform infrared spectroscopy). Combustion toxicity index Lethal Fractional Effective Dose ($L_{FED}$) of ISO 13344 was calculated. According to the result of calculating Lethal Concentration 50% ($LC_{50}$) based on $L_{FED}$, $LC_{50}$ of urethane sample containing certain level of fire load is confirmed as $118{\sim}129g/m^3$. Through this study, applicability of this method was confirmed for fire risk assessment. This method can provide information to predict human damage by toxicity combustion gas for securing safety.

Experimental study on applicability of compressed air foam fire water using seawater in train fire at subsea tunnel rescue station (해저터널 구난역 열차화재시 압축공기포 소화용수의 해수 적용성에 관한 실험 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.705-715
    • /
    • 2017
  • In this study, applicability of compressed air form (CAF) fire water was verified in a bid to use the undersea effluent as fire water. Foam collector was fabricated in accordance with KS B ISO 7203-1 (Specification for low expansion foam concentrates for top application to water-immiscible liquids) and the test was conducted using fresh water as fire water for 19 times and using seawater as fire water 15 times that totaled 34 times. Foam reduction time was 237.73 seconds on average with fresh water and 215.60 seconds with seawater, which proved the applicability of CAF fire water using seawater. Besides, window breaker was fabricated to directly extinguish the fire in train and a full-scale fire test was conducted three times. At the final 3rd test, window glass was broken in 2 seconds to make the hole for fire extinguishing and suppressed the fire in 3 seconds using CAF fire extinguisher.

Occurrence of EDC/PPCPs in Influent and Effluent of a Wastewater Treatment Plant (하수처리장 유입.유출수 내 EDC/PPCPs의 발생 특성)

  • Lee, Min-Ju;Ryu, Jae-Na;Oh, Je-Ill;Kim, Hyun-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.783-792
    • /
    • 2009
  • This study investigated 31 selected EDCs(Endocrine Disrupting Compounds) and PPCPs(Pharmaceutical and Personal Care Products) in the influent and effluent of a wastewater treatment plant(WWTP) nearby Seoul metropolitan area. The chemical compounds of EDC/PPCPs detected from the plant influent sample include stimulant, X-ray contrast media and fire retardant. The total amount of each compound class were 59.67%, 20.20% and 9.00% respectively. However, in the effluent sample, the major micropolutants detected were oral beta-blocker(30.54%), fire retardant(20.49%), X-ray contrast media(18.17%). The EDC/PPCPs occurrence levels of this study were somewhat lower than previous domestic studies'. When compared to those of overseas, the values were even lower. Some pharmaceutical compound levels particularly measured in European studies were even several thousand times high. This study then compared PECs(Predicted Environmental Concentration) and MECs(Measured Environmental Concentration) of 9 selected pharmaceuticals compounds. The calculated PECs were substantially different with the MECs, while the occurrence order between the PECs and MECs in terms of concentrations of the compounds were similar.

Review of Safety for Pressure-Relieving Systems of Small to Middle Scale Chemical Plants (중소규모 화학공장의 압력방출시스템에 대한 안전성 검토)

  • Yim, Ji-Pyo;Jin, Dae-Young;Ma, Byung-Chol;Kang, Sung-Ju;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.48-55
    • /
    • 2015
  • A variety of safety issues were investigated for chemical reactors using a toluene solvent in case of a fire at small to middle scale chemical plants. The issues covered the operation of pressure-relieving valves and the subsequent discharges of the toluene to the atmosphere either directly or through an absorber, which represent the current practice at most small chemical plants. It was shown that the safety valve on the reactor may not operate within about twenty minutes after an external fire breaks out, but, once relieved, the toluene vapor released directly to the atmosphere may form a large explosion range on the ground. It was also shown that if the discharge is routed to an existing absorber used for the scrubbing of volatile organic compounds or dusts, the column may not operate normally due to excessive pressure drops or flooding, resulting in the hazardous release of toluene vapors. This study proposed two ways of alleviating these risks. The first is to ruduce the discharge itself from the safety valve by using adequate insulation and protection covers on the reactor and then introduce it into the circulation water at the bottom of the absorber through a dip linet pipe equipped with a ring-shaped sparger. This will enhance the condensation of toluene vapors with the reduced effluent vapors treated in the packing layers above. The second is to install a separate quench drum to condense the routed toluene vapors more effectively than the existing absorber.

Research of Sea Food Wastewater Treatment using Membrane Filter (Membrane Filter를 이용한 수산물 가공폐수처리에 대한 연구)

  • Han, Dong-Joon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.4
    • /
    • pp.119-130
    • /
    • 2007
  • Sea food wastewater including high concentration of organics and nutrients is hard to treat stably by established traditional activated sludge process. This research is aimed to obey more and more of strengthened the law and to secure stable effluents by using advanced treatment process applied membrane filter in aeration tank for treatment of wastewater from marine products. It must maintain pH of influent over 6.0 to keep up stably biological sludge of advanced treatment process. At 38hr of HRT, removal rates of TBOD and TCOD were 99.9% and 99.4% respectively and TSS also removed with high efficiency. Most organics in the effluent was constituted with soluble type materials, it caused that membrane filter installed aeration tank should remove minute suspended particles. The reactor was operated well to get stable treatment results for operation period, in spite of high loading of organics like that $0.67{\sim}1.67\;kgTBOD/m^3/day$ of organics loading and $0.10{\sim}0.21\;kgBOD_5/kgMLSS/day$ of F/M ratio. At $36{\sim}48hr$ of HRT, removal rates of T-N and T-P were $89.7{\sim}90.7%\;and\;91.5{\sim}96.0%$ respectively. It means this treatment process also work to remove nutrients of high concentration. Upon investigation of advanced treatment's operation factors, optimum SRT was about 30days and average SNR that showed tendency to increase according to increase water temperature was calculated 0.014 gN/g MLVSS/d. SDNR was risen in conformity to increase F/M ratio of Non-aeration tank and investigated as $0.038{\sim}0.051\;gN/gMLVSS/d$.

Study of Smoking Booth Design for the Treatment of Hazardous Pollutants (유해오염물질 처리를 위한 흡연부스의 설계)

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.107-111
    • /
    • 2017
  • The purpose of this study was to develop a Eco smoking booth that can effectively reduce hazardous pollutants generated during smoking and evaluate the efficiency and effectiveness of removing hazardous pollutants. The design and manufacture of an eco-friendly automatic smoking booth equipped with deodorizing facilities, such as inlet - HEPA filter - electrostatic precipitator (EP) - impregnated activated carbon - exhaust port, etc., and the efficiency of removing hazardous pollutants from inside and outside was measured and evaluated. The complex odor removal efficiency was 95.37% inside the smoking booth, and 97.38% at the exit of the preventive facility. The carbon monoxide removal efficiency was 94.25% in the inside and 98.32% in the outlet. In addition, the removal efficiency of particulate matter, (PM1, PM2.5, and PM10) inside the smoking booth was 98.59%, and 98.85% at the outlet. The total volatile organic compounds (TVOCs) decreased from $26,000{\mu}g/m^3$ to $5,203{\mu}g/m^3$ in the smoking booth, resulting in 79.99% removal efficiency. After the ventilator was operated, the measured effluent concentration was $5,019{\mu}g/m^3$, and the removal efficiency was 80.70%. Therefore, the smoking booth designed and manufactured through this study can be applied to the removal of harmful pollutants even in the small working environment in the future.