• Title/Summary/Keyword: Fire damage characteristics

Search Result 184, Processing Time 0.028 seconds

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface

Forest Stand and Site Characteristics in Post Forest Fire Area and Management Treatments for Optimal Vegetation Restoration (산화지의 입지와 임분특성 및 경영시업에 따른 식생변화 추이분석)

  • Lee, Kwang-Soo;Kim, Suk-Kwon;Bae, Sang-Won;Lee, Kyung-Jae;Kang, Young-Jae;Jung, Su-Young;Moon, Hyun-Shik
    • Journal of agriculture & life science
    • /
    • v.43 no.6
    • /
    • pp.19-27
    • /
    • 2009
  • This study was carried out to obtain the basic model to estimate damage degree from the correlation analysis between forest fire and site environment factors and to clarify the restoration trends thorough multi-temporal survey by observing species diversity followed by various treatments at damaged forest area over time. From the derived model, the damage degree of forest fire was higher in the area of dense coniferous stands composed of simple story at the elevation of about 100m and 200m, and on steeper slope area over 30 degree. As results of this study, fire damaged trees are needed to cut down and a mixed stand with deciduous and coniferous species from the same area is desirable for the future species composition on fire damaged forest. Thus, site characteristics, local species, and mixed stands are the main consideration to enhance the vegetation recovery.

Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism (가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.

A Study on the Fire-Safety Design for the Historic Buildings (역사적 건조물의 화재안전을 위한 기초연구)

  • Lee Ji-Hee
    • Journal of the Korean housing association
    • /
    • v.15 no.6
    • /
    • pp.107-113
    • /
    • 2004
  • Fire was and remains a great threat to historic buildings of wood. This threat is omnipresent and often results to irreparable property losses especially cultural heritages. Fire of historic buildings continues to increase every year. The purpose of this study is to preserve a life safety, historical heritage and architectural & cultural values by pursuing for fire safety in the historical buildings. This study shall employ two research methods: a literature review and field survey methods. The literature review shall focus on the observations of characteristics noted in fire codes. The field survey shall cover a heat analysis and fire protection equipment. A method is proposed to investigate fire codes related historical building, reported fire history Fire Codes and Regulations for modern buildings are not always applicable on the historic buildings. Old buildings, and some new buildings with architectural, historical or cultural importance may have values which cannot be measured on a monetary scale. Their protection against the damage caused by fire is considered to be one of the basic moral duties of society. It is strongly recommended, therefore, legislation for fire safety in historical buildings must be extended to a complementary relationship with 'active' fire protection measures, to provide safety in real historical building in real fire situations. The development and application of performance based Codes and the Fire Safety Engineering approach seems to be a rather reasonable and effective way to deal with this historical buildings.

Experimental Study on Moisture Content According to Addition of Surfactants (계면활성제 첨가에 따른 함수율에 관한 실험적 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.79-83
    • /
    • 2015
  • The fire accident is a representative type of disaster that can largely impact on business. Therefore, precautionary measures and rapid initial response is very important when a disaster occurs. The storage of porous combustibles is inevitable in coal yard, plywood processing industry, and others that are currently operating. Initial fire fighting of fire and identifying the ignition point in such a porous combustible storage space are so difficult that if the initial response is failed, being led to deep-seated fire, surface fire is likely to result in secondary damage. In addition, deep-seated fire can cause personal injuries and property damage due to a large amount of toxic gases and reignition. Therefore damage reduction measures is required around the storage space to handle a porous flammable. Improving the penetration performance of the concentration of the surfactant is carried out as underlying study, which is about an deep-seated fire extinguishing efficiency augmentation when using wetting agents. The porous materials used in the experiments is radiata pine wood flour, which occupies more than 75% of the domestic wood market. Fire fighting water is selected as Butyl Di Glycol (BDG), which is being used for infiltration extinguishing agent, and the experiment was carried out by producing a standard solution. The experiment was carried out on the basis of the Deep-Seated Fire Test of NFPA 18. The amount of watering, porous material to the internal amount of penetration, and runoff measurement out of the porous material was conducted. According to experimental results, as the surface tension is reduced, the surfactant concentration macroscopic penetration rate decreases, but infiltration to a porous material is shown to have growth characteristics.

A Study on Fire Flame Detection Performance in the Images of Various Color Spaces (다양한 컬러 공간에 따른 영상 내 화염 검출 성능 연구)

  • Choi, Byung-Soo;Kim, Jeong-Dae;Do, Yong-Tae
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.284-286
    • /
    • 2012
  • There has been increasing attention about the prevention and counter-measure of disasters. Particularly, for the case of fire disaster, early detection reduces the damage caused by fire significantly and effective detection method is important. Since most existing detectors need to be located at a close distance to fire, analyzing camera images to find fire becomes active research topic. In this paper, we analyze the color characteristics of fire images in various color spaces and report the experimental detection results. The best result is 77.8% success rate in YIQ space.

  • PDF

Fire Resistance of Repaired High Strength Concrete Column Damaged by Fire (화재 피해를 입은 고강도 콘크리트 기둥의 보수공법 변화에 따른 내화특성)

  • Park, Chun-Jin;Back, Dae-Hyun;In, Gi-Ho;Yeo, In-Hwan;Min, Byung-Yeol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.113-116
    • /
    • 2009
  • This study analyzed fire-resistant characteristics according to changes in repair methods of PFH mixed high-strength concrete roof structures having undergone fire damage. The results of the study are as follows. First, as a repulsive characteristics of structures, the remaining repulsion was shown to increase following fire-resistance tests according to increases in depth of coverings. The results of the relationship between depth of coverings and remaining repulsion rates following fire-proofing tests showed a high correlation. At a covering depth of 67.3mm, remaining repulsion rate was estimated to be 100%. For fire-resistant characteristics following repairs of structure, as for spalling, severe separation was shown in the case of general plaster while general plaster + Metal Lath showed overall superior spalling prevention. For internal structure temperatures, general plaster showed max temperatures of 705℃, average temperatures of 636℃ while general plaster + metal lath showed max temperature of 660℃ and average temperature of 520℃, demonstrating lower temperature distributions than use of only general plaster. In conclusion, after removing the covering of structures damaged due to high temperatures of fires within high-strength concrete installations, the use of fire-resistant mortars and applying metal laths on surfaces of general plaster will provide superior fire-resistance performance in the occurrence of a 2nd fire.

  • PDF

A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables (동파방지열선 화재 흔적분석과 발화원인 연구)

  • Lee, Jung Il;Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

Anatomical and Physical Characteristics of Pinus densiflora Wood Damaged by Forest Fire - Difference by Damage Level - (산불 피해 소나무 목재의 해부 및 물리적 특성 - 피해 정도에 따른 차이-)

  • Kwon, Sung-Min;Chun, Kun-Woo;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.84-92
    • /
    • 2008
  • Anatomical and physical characteristics of Pinus densiflora woods damaged by forest fire at Yangyang-gun, Kangwon-do were investigated in present study. Even though the bark was severly carbonized, no trace of carbonization in the xylem was found. The amount of resin exudation was different by the degree of fire damage. Green moisture content of sapwood in the damaged wood was lower than that in the sound wood, but vice versa in the heartwood. Green density of heartwood in the damaged wood was higher than that in the sound wood, but there was no significant difference in sapwood. Cambial activities were found stopped in the severely damaged wood but were identified in the lightly damaged wood. In safranine staining process, epithelial and ray parenchyma cell walls in the damaged woods showed darker hue than those in the sound wood. Granular substances were observed in the lumina of ray parenchyma and epithelial cells of the severely damaged wood. Relative crystallinity of the outermost growth ring in the severely damaged wood was slightly higher than that in the sound wood.