• Title/Summary/Keyword: Fire damage

Search Result 1,092, Processing Time 0.03 seconds

The Impact of Building Types on Fire Damage by Month

  • Yi, Kyoo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.567-575
    • /
    • 2019
  • Statistics show that while the number of fires has decreased over the last decade, losses of human life and economic property due to fire have increased. Moreover, the number of large-scale fires that have occurred in recent years has resulted in heightened public anxiety. This study aims to identify a specific period of the year most vulnerable to fire, and fire trends, such as damage of fire to humans, to the economy, and different building types. For this purpose, we analyzed human and economic damages using statistics related to fire from 2007 to 2017 and provided a monthly distribution of fire damages both to humans and to the economy by building type. We also identified the relationship between the human damage and the economy damage, and compared the economic losses per casualty by building type. The human damage in residential buildings occupied the highest portion, whereas the economic damage of industrial buildings represented more than a half of all economic damage due to fire. The economic damage per casualty was shown highest for industrial buildings and has also increased rapidly in recent years.

Experimental study on cyclically-damaged steel-concrete composite joints subjected to fire

  • Ye, Zhongnan;Jiang, Shouchao;Heidarpour, Amin;Li, Yingchao;Li, Guoqiang
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.351-364
    • /
    • 2019
  • Earthquake and fire are both severe disasters for building structures. Since earthquake-induced damage will weaken the structure and reduce its fire endurance, it is important to investigate the behavior of structure subjected to post-earthquake fire. In this paper, steel-concrete composite beam-to-column joints were tested under fire with pre-damage caused by cyclic loads. Beforehand, three control specimens with no pre-damage were tested to capture the static, cyclic and fire-resistant performance of intact joints. Experimental data including strain, deflection and temperature recorded at several points are presented and analyzed to quantify the influence of cyclic damage on fire resistance. It is indicated that the fire endurance of damaged joints decreased with the increase of damage level, mainly due to faster heating-up rate after cyclic damage. However, cracks induced by cyclic loading in concrete are found to mitigate the concrete spalling at elevated temperatures. Moreover, the relationship between fire resistance and damage degree is revealed from experimental results, which can be applied in fire safety design and is worthwhile for further research.

Assessment of Fire-induced Damage to Tunnel Structural Members at Different Fire Scenarios (화재이력에 따른 터널구조물 시공재료의 화재손상 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Kwon, Jong-Wook;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.960-969
    • /
    • 2006
  • In this study, a series of fire tests was carried out to evaluate fire-induced damage to structural members in tunnels. From the tests, the loss amount of concrete materials by the RWS fire scenario was slightly bigger than by the RABT fire scenario. Especially under the RWS fire scenario where the maximum temperature is over 1,200, the loss of concrete materials was mainly induced by melting. Generally, the loss of materials in reinforced concrete was slightly smaller than that in unreinforced concrete. Depending upon an applied fire scenario, fire-induced damage to shotcrete was quite different. From the real-time investigation of a specimen surface by a digital camcorder, it was proved that the material loss under the RABT fire scenario was mainly induced by spalling. However, it was also revealed that although fire-induced damage in the initial heating stage under the RWS was so close to that under the RABT, the material loss under the RWS at the later stage after 50 minutes elapsed since fire initiation was induced not by spalling but by melting.

  • PDF

Damage Degree Valuation of Forest Using NDVI from Near Infrared CCD Camera and Spectral Radiometer in a Forest Fire Area (근적외 CCD카메라와 분광반사계의 식생지수를 이용한 산불 발생지역에서의 산림 피해도 평가)

  • Choi, Seung-Pil;Kim, Dong-Hee;Park, Jong-Sun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.4
    • /
    • pp.367-374
    • /
    • 2005
  • Recently, forest damage has occurred often and made big issues. Among them, the damage by forest fire is not only damage of itself but also being connected with secondary damage like a flood. This is the fact that a forest fire is caused rather artificially by people than nature. In this study, we try to investigate damage of a forest fire through spectral reflectance of a plant community surveyed using a near infrared CCD camera and a SPM (Spectral Radiometer) as advanced work to use satellite image data. That is, damage of a forest fire by the naked eye observation was divided into the No damage, the light damage, the serious damage and we estimated activity of forest and grasped revival possibility of forest. Through correlation analysis between the spectral reflectance by SPM and the near infrared CCD camera, we could get high correlation in the No damage and light damage. Therefore, when we surveyed damage of a forest fire, we could grasp damage, that is hardly observed by the naked eye by, using jointly the spectral radiometer and the near infrared CCD camera.

The Analysis of the Risk of Vehicle Fires in Korea and the Effectiveness of Initial Fire Extinguishing (국내 자동차 관련 화재발생 위험성 분석 및 초기소화의 효과성 연구)

  • Ryu, Juyeol;Lee, Changwoo
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.20-27
    • /
    • 2019
  • Purpose: In this study, the status and the risk of fire occurrence in domestic automobile were evaluated and the damage reduction effect by using the fire extinguishing mechanism was evaluated. Method: The analysis of the risk of the occurrence of Vehicle Fires in Korea and the damage of human and property by the use of fire extinguisher applied to fire extinguisher were investigated and analyzed. Results: The annual damage rate of the damage caused by the automobile fire is 4.74%, which shows an annual increase. As a result of the analysis of the personal injury caused by the passenger car in the car fire situation, the damage amount per 100 cases of the fire occurrence increased from 424.65 million won to 473.06 million won in the past 5 years (2012 ~ 2016). Conclusion: When fire extinguishers are used in the case of passenger Vehicle Fires, the average amount of property damage per fire occurrence is estimated to be about 307.5 million, emphasizing the importance and necessity of the initial fire fighting.

Evaluation of Salt Damage Resistance of Concrete according to Fire Control Time (화재진압시간에 따른 콘크리트의 염해저항성 평가)

  • Lee, Jun-Hae;Park, Dong-cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.109-110
    • /
    • 2020
  • In the event of a fire, fire engines usually arrive within 15 minutes and become a fire suppressor. In this paper, an analytical model was established to evaluate the salt damage resistance of concrete according to fire suppression time, and the concentration of salt inside the concrete after fire was measured and the time to reach the critical concentration was assessed by how short.

  • PDF

Pohang City Fire Vulnerable Area Prediction and Fire Damage Rating Measurement by Administrative District (포항시 화재 취약지역 예측 및 이에 따른 행정구역별 화재 피해 등급 측정)

  • Lim, Jung-Hoon;Kim, Heon-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.4
    • /
    • pp.166-176
    • /
    • 2021
  • Due to urbanization and industrialization, the importance of large-scale fire prevention, management and measures is increasing day by day. However, the fire site arrival rate in Golden Time, which is a factor that can minimize large-scale fire damage, of Pohang, a large city with a population of over 500,000, is relatively low. So additional fire fighting power deployment and infrastructure investment are required. However, as budget and manpower are limited, it is necessary to selectively deploy fire fighting power and invest in infrastructure. Therefore, this study attempted to present a fire damage rating that can compare the level of fire damage, which is an index that can help selectively provide fire fighting services in Pohang and make related decisions. For the index, the OD cost matrix was used to predict fire vulnerable areas with a high probability of increasing the fire scale in the event of a fire. Also fire damage was measured by predicting the level of fire damage in the event of a fire according to population, building density, and access of fire trucks. It is expected that the fire damage rating will be able to help in various decisions related to fire fighting service deployment and services not only in Pohang city, but also in other regions.

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

On modeling of fire resistance tests on concrete and reinforced-concrete structures

  • Ibrahimbegovic, Adnan;Boulkertous, Amor;Davenne, Luc;Muhasilovic, Medzid;Pokrklic, Ahmed
    • Computers and Concrete
    • /
    • v.7 no.4
    • /
    • pp.285-301
    • /
    • 2010
  • In this work we first review the statistical data on large fires in urban areas, presenting a detailed list of causes of fires, the type of damage to concrete and reinforced concrete structures. We also present the modern experimental approach for studying the fire-resistance of different structural components, along with the role of numerical modeling to provide more detailed information on quantifying the temperature and heat flux fields. In the last part of this work we provide the refined models for assessment of fire-induced damage in structures built of concrete and/or reinforced-concrete. We show that the refined models of this kind are needed to provide a more thorough explanation of damage and to complete the damage assessment and post-fire evaluations.

A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System (소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF