• Title/Summary/Keyword: Fire current

Search Result 849, Processing Time 0.024 seconds

Analysis on the Voltage, Current and Temperature Signals for Free and Locked Operation of Three Speed Electric Fan (3단 스피드 선풍기 모터의 정상 및 고정 운전에 대한 전압, 전류 및 온도 신호 분석)

  • Kim, Yoon Bok;Kim, Doo Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.87-91
    • /
    • 2014
  • This paper is aimed to find electrical fire danger for analyzing the characteristics of temperature, current and voltage signals for motor on electric fan. In order to attain this purpose, detected were the temperature, current and voltage signals on electric wire with free (normal state) and locked (abnormal state) motor. For voltage and current signals, voltage signal is no big difference with normal and abnormal states and current signal is higher in abnormal state (highest 309 mA) than the normal state (highest 203 mA). In the case of Temperature signal, the temperature distribution of the motor as a whole is different. It is difference in the case of the normal state $4^{\circ}C$ and the abnormal state $18^{\circ}C$. In particular, most of the electric wiring to the motor of the fan is attached to the fixture of motor back. Considering at allowable temperature ($60^{\circ}C$) of the electric wire could be accelerated to insulation deterioration. The results of this study will be effectively used in analyzing for electric fire and developing the preventive devices of electric fan.

Arc Detection and Interruption Algorithm Design for Fire Protection (화재 방지를 위한 아크전류 검출 제어기 설계)

  • Ban, Gi-Jong;Won, Young-Jin;Lim, Seung-Ha
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.19-24
    • /
    • 2005
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc current controller does not have the arc current interrupt function. Hence, Controller of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

A Basic Study for the Fire Potentiality in Wire being Applied Electric Current (통전중인 도선에서 화재 가능성에 관한 기초 연구)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.72-77
    • /
    • 2009
  • In total electric fire in Korea in 2006, a rate of the electric fire caused of short in electric wire is over 63.2[%]. It is needed to study a fire potentiality in electric wire. This paper studies contact and fire potentiality between a electric wire and conductors existed around the electric wire. As amplitude of current in electric wire is bigger, as it has higher possibility to contact between a electric wire and conductors existed around the electric wire. In case of temperature of wire is over combustion point of outer sheath, it is appeared to spark discharge between wire and conductors. So the fire potentiality raise up.

A Study on the Development of the Photo-electric Single Station Smoke Alarm of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력의 광전식 단독경보형감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • This is a case report of a photo-electric single station alarm for residential fire prevention. The detector was developed for the certification in Japanese market which is more than 100 times bigger than Korean market. A comparison and review for test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively is also conducted. The detector alarms with a buzzer and an indicating LED. Operating period and time in alarm, low battery and fire situation is stated. The electronics circuit part to reduce its current and the detector's characteristics are described. It is explained that the measured current and experimental result of the battery discharge can meet the 10 years operation.

A Study on the Over-current Characteristics of IV Insulated Wire Sheath According to Accelerated Degradation (가속열화에 따른 IV절연전선 피복의 과전류 특성에 관한 연구)

  • Kim, Si-Kuk;Choi, Su-Gil
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.48-56
    • /
    • 2018
  • This paper reports the results of a study on the over-current characteristics of IV insulated wire sheath according to accelerated degradation. In order to examine the degradation of a IV insulated wire sheath through insulation, acceleration degradation experiments were performed using the Arrhenius equation of acceleration life test models; test samples with equivalent lives of 0, 10, 20, 30 and 40 years were prepared. Then allowed currents with over-current of 100%~500% were introduced to measure the times of first generation of smokes and carbonization in the wire sheath, and it was found that the times of first generation of smokes and carbonization in the wire sheath decreased as the equivalent life increased. In more detail, when 270% over-current is applied, the electrical fire risk of equivalent life of 40 years increased by approximately 3.2 times based on equivalent life of 0 years. Also, when the over-current was 255% and 260%, carbonization occurred only in the equivalent life of 40 years, and the fire risk according to the accelerated degradation was increased dramatically. In addition, FT-IR and SEM analyzes were used to confirm the characteristics and surface changes of IV insulated wire sheath according to the equivalent life.

An approach for calculating the failure loads of unprotected concrete filled steel columns exposed to fire

  • Wang, Y.C.;Kodur, V.K.R.
    • Structural Engineering and Mechanics
    • /
    • v.7 no.2
    • /
    • pp.127-145
    • /
    • 1999
  • This paper deals with the development of an approach for evaluating the squash load and rigidity of unprotected concrete filled steel columns at elevated temperatures. The current approach of evaluating these properties is reviewed. It is shown that with a non-uniform temperature distribution, over the composite cross-section, the calculations for the squash load and rigidity are tedious in the current method. A simplified approach is proposed to evaluate the temperature distribution, squash load, and rigidity of composite columns. This approach is based on the model in Eurocode 4 and can conveniently be used to calculate the resistance to axial compression of a concrete filled steel column for any fire resistance time. The accuracy of the proposed approach is assessed by comparing the predicted strengths against the results of fire tests on concrete filled circular and square steel columns. The applicability of the proposed approach to a design situation is illustrated through a numerical example.

The Infrastructure Case for Reproduction or Analysis of The Mechanism on The Fire of The Electrical Appliances (가전제품 화재 메커니즘 재현 및 분석을 위한 인프라 구축)

  • Jang, In-Hyeok;Lee, Chang-Hoon;Lee, Young-Joo;Lim, Hong-Woo
    • Journal of Applied Reliability
    • /
    • v.15 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • In this paper, The infrastructure case for reproduction or analysis of the mechanism on the fire or the electrics shock of the electrical appliances is proposed. The various electrical appliances(Washing machine, Ballast, Electric heaters, Electronic switches, Mobile phone chargers) used in the home can be tested on the high voltage and over current test through the implementation of the infrastructure. The electrical tests of fire and electric shock consists of the high voltage of maximum 5000 V and over current test of 3 steps(90 A, 60 A, 40 A) and noise test. The mechanism of the fire and the electric shock tests reproduced are analyzed through the monitoring system and the oscilloscope. The electronics manufacturers can prevent accidents through the tests of the electronics factor reproduced and the analysis of the infrastructure designed.

Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire (통전 중 산불에 노출된 가공송전선의 온도 및 장력 변화 거동)

  • Kim, Byung-Geol;Jang, Young-Ho;Kim, Shang-Shu;Han, Se-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.4
    • /
    • pp.366-371
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperatures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

Literature Review and Current Trends of Automated Design for Fire Protection Facilities (화재방호 설비 설계 자동화를 위한 선행연구 및 기술 분석)

  • Hong, Sung-Hyup;Choi, Doo Chan;Lee, Kwang Ho
    • Land and Housing Review
    • /
    • v.11 no.4
    • /
    • pp.99-104
    • /
    • 2020
  • This paper presents the recent research developments identified through a review of literature on the application of artificial intelligence in developing automated designs of fire protection facilities. The literature review covered research related to image recognition and applicable neural networks. Firstly, it was found that convolutional neural network (CNN) may be applied to the development of automating the design of fire protection facilities. It requires a high level of object detection accuracy necessitating the classification of each object making up the image. Secondly, to ensure accurate object detection and building information, the data need to be pulled from architectural drawings. Thirdly, by applying image recognition and classification, this can be done by extracting wall and surface information using dimension lines and pixels. All combined, the current review of literature strongly indicates that it is possible to develop automated designs for fire protection utilizing artificial intelligence.

A Study on the Detection Technique of the Flame and Series arc by Poor Contact (접촉 불량에 의한 불꽃 및 직렬아크의 검출 기법에 관한 연구)

  • Woo, Kim Hyun;Hyun, Baek Dong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.24-30
    • /
    • 2012
  • This study is on the method of the detection for flame and series arc which can be happened at poor contact point added a vibration in part of contact point of low voltage line. In general, the causes of electric fire are over current, short circuit, poor contact, ect. The over-current or short circuit among those causes is detected by measuring a instant current value, but poor contact is difficult to detect by measuring a excessive value of the voltage and current and a distortion of waveforms. And therefore, in this paper, it is studied on the optimal technique of the arc judgement using fuzzy logic and MDET (Multi Dimension Estimation Technique). And it carries out the simulation for arc detection and the experiment for controller and load test. In result, the controller and detection algoristhm, is classified with normal wave and abnormal arc wave without relation with each loads and so the controller can detect a series arc successfully.