• 제목/요약/키워드: Fire case analysis

검색결과 590건 처리시간 0.026초

시뮬레이션을 이용한 철도터널 화재 사고의 승객 안전도 분석 (A Study on Analysis of Passenger Safety in Railroad Tunnel Fire - Using Simulation -)

  • 김동진;문성암;김동건;김경섭;장용준;정우성
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.131-136
    • /
    • 2007
  • In this paper, the methodology to predict the number of deaths and possible fire propagation scenarios will be described in case of fire on a train in a tunnel. We use a probabilistic analysis method for the evaluation of possibility for each scenario and the deaths tolls are calculated with the help of the passenger evacuation simulation program. The resulting safety of passengers is displayed on a F/N graph, which could be used in part as a guideline to predict the safety level of the tunnel in fire.

소방차전용출동경로의 계획기법 및 적합성 검토에 관한 연구 - 대구광역시 북구를 대상으로 - (Consideration about the Fire Lane Plan and the Conformability - A Case Study on Daegu Metropolitan City Buk-gu -)

  • 정군식;김한수
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.83-90
    • /
    • 2010
  • 본 연구는 지역의 방재성능향상을 위해 소방차 출동경로의 계획기법 및 기준마련을 위한 기초연구이다. 지역의 방재적 특성파악을 통하여 발생예상재난을 규정지었으며, 현행 소방차의 출동경로선택모델의 작성 및 네트워크해석을 통하여, 도시규모 대형재난의 발생 시에 다양한 출동경로계획의 유효성을 입증하였다. 그리고 실재(實在) 도로망을 바탕으로 네트워크모델을 작성하고 해석을 통하여, 출동경로상의 장해의 위험성에 대하여 정량적인 검토를 행하였으며, 소방차출동전용도로계획에 대한 형태학적 분석을 행하였다. 본 연구의 성과는 합리적이고 효과적인 소방차출동전용도로(Fire Lane)의 형태학적 계획과 정량적인 분석을 위한 기초자료로써의 활용이 기대된다.

화재 안전용 볼밸브의 열·구조 연성해석 (Thermal-structural Coupled Field Analysis for Fire Safety Type Ball Valve)

  • 김시범;이준호;이권희;전락원;도태완
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.28-32
    • /
    • 2011
  • The safety of transporting equipment in a cryogenic condition is one of important problems under the circumstances that the application weight of natural gas is gradually increasing. As a larger disaster may be generated by leakage of oil or gas from valves in case of fire occurrence of a ship, the present research applied a numerical analysis method on thermal stress distribution and deformation, etc. to the design of ball valves satisfying fire safety test's specification(API607) to prevent this. In addition, the present research progressed fire safety tests and compared the test result with numerical analysis results. The Max stress by parts was confirmed through thermal analysis of major parts to evaluate safety. The fire safety test was progressed according to the regulation of API607.

건축용 외장재와 접착제 연소가스의 독성분석에 관한 연구 (A Study on the Toxicity Analysis of Combustion Gases of Architectural Surface Materials and Architectural Adhesives)

  • 김원종;박영주;이해평;임석환;김정인
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.48-52
    • /
    • 2013
  • This study was carried out, using toxicity test apparatus, to analyze toxic gases of heat insulation material and adhesives of composite panels used for the architectural surface material when a fire occurs. The findings of this study show that CO, $CO_2$, HCOH, $CH_2CHCN$ and $NO_x$ were detected from styrofoam, reinforced styrofoam, polyurethane foam and glass fiber, but in the case of the polyurethane foam, HCl and HCN were detected as well. All the architectural adhesives released CO, $CO_2$ and $NO_x$, but HCHO was only detected from the adhesives for styrofoam, wood, tile, windows and doors; $CH_2CHCN$ was only from those for wood and stone; $C_6H_5OH$ was only from those for wood. The toxicity index was also measured for architectural surface material and adhesives. Polyurethane foam showed the highest index, 11.7, and glass fiber was followed as 6.8. Reinforced styrofoam showed 5.7 and styrofoam revealed the least 4.9. In the case of architectural adhesives, the highest ranking was those for stone 7.4, windows and doors 6.1, wood 5.3, tile 3.8, and styrofoam 3.7 were followed, respectively.

주행 중 발생한 자동차화재를 엔진정지 주차 후 발견한 화재 사례 분석 연구 (A Study on Case Analysis of Motor Vehicle Fires Which Occurred in Operation but Were Found after Parking)

  • 이의평
    • 한국자동차공학회논문집
    • /
    • 제20권6호
    • /
    • pp.9-16
    • /
    • 2012
  • It is often thought that when a fire is found in parked motor vehicles, the fire may occur after an engine stops. Also, it is easy to judge that when motor vehicle fires occur during engine stopping, it may be caused by arson or electrical causes irrespective of a fuel system. This study analyzed motor vehicle fires which occurred in operation but were found after parking and revealed that these fires were caused by the defect of a fuel system and the same motor vehicle types had fires by the same causes. Moreover, this study provided judgement process of major fire causes and periods for fire investigators to apply when investigating fires of parked motor vehicles. And this fire is related to automotive products liability.

초고층 건물의 재난 발생 시 작전전술 방안 (The Way of operations and tactics for Disaster plan of High-rise Buildings)

  • 이정일
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.77-83
    • /
    • 2012
  • Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.

고양종합터미널화재 시 스크린방화셔터의 작동실태 분석 (Analysis of the Working Conditions of Screen Fire Shutters in the Goyang Bus Terminal Fire)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권2호
    • /
    • pp.82-91
    • /
    • 2018
  • 고양종합터미널 건물 화재 조사 결과를 토대로 스크린방화셔터의 작동실태 및 문제점 등에 대해 분석하였다. 공사 중이던 지하 1층 공간의 스크린방화셔터는 전원을 차단하여서 작동할 수 없었다. 1층과 3층의 스크린방화셔터는 전원을 차단하지 않았음에도 4개가 작동하지 않았다. 그리고 스크린방화셔터와 관련된 문제점으로 면적별 방화구획을 변경하는 공사를 함에도 층별 방화구획용 스크린방화셔터 전원 차단, 아무런 규제 없이 일체형스크린방화셔터 설치, 피난장애와 관련이 없는 곳에도 2단 스크린방화셔터 설치, 가연성 샌드위치패널로 칸막이 후 층별 방화구획용 스크린방화셔터 기능 정지, 성능이 검증되지 않은 폭 10 m 이상의 스크린방화셔터 설치, 방화셔터 이설 또는 정비 시 안전관리 기준이 없음 등으로 분석하였다.

지하철 터널내의 객차 화재발생시 환기실 위치변화에 따른 화재특성의 수치적 연구 (Numerical Predictions of Fire Characteristics of Passenger Train Fire in an Underground Subway Tunnel, Depending on Change of Location of Ventilation Facility)

  • 손봉세;장희철
    • 한국화재소방학회논문지
    • /
    • 제22권5호
    • /
    • pp.1-8
    • /
    • 2008
  • 본 연구의 목적은 지하철 터널에서 화재가 발생한 경우 역사와 환기실의 위치에 따른 화재특성을 수치적으로 분석하는데 있다. 이를 위해 피난거리, 피난시간 및 최악조건 화재가 발생한 2가지 시나리오를 선정하고, 환기실 위치 변경에 따른 시간별 화재상황에 대한 터널내의 시류 및 열환경을 분석하였다. 화재해석을 위해 FLUENT v.6.3.26을 이용하였으며, 난류모델은 표준 k-${\varepsilon}$ 모델을 사용하였다. 경우에 따른 터널 내 일산화탄소의 농도 분포, 온도분포 및 속도분포의 결과를 분석하였고 본 연구의 결과는 지하철 역사 및 터널 설계시 최적의 방재 및 환기시스템을 구축하는데 기여할 것으로 생각된다.

박리를 고려한 지하박스구조물의 화재하중해석 I : 박리해석 (Fire Loading Analysis of Underground Box Structure with Considering of Concrete Spalling I : Spalling Analysis)

  • 이계희;최익창
    • 한국전산구조공학회논문집
    • /
    • 제20권4호
    • /
    • pp.477-483
    • /
    • 2007
  • 본 연구에서는 전력구나 공동구와 같은 지하 콘크리트박스구조물의 화재발생시 온도분포와 박리거동에 대한 수치해석을 수행하였다. 해석에 사용된 온도장은 터널화재에 사용하는 화재곡선을 기본으로 하고 화재시 내부공간에 대한 열유체해석을 수행하여 온도분포를 결정하였다. 박리거동은 탈수화도를 따라 콘크리트의 온도가 기준값에 도달하였을때 발생하는 것으로 하였다. 이때 박리가 일어난 요소를 제거하고 경계조건과 요소망을 재생성하여 해석을 반복수행하였다. 3개의 화재 시나리오에 따라 해석을 수행하였고, 해석결과는 각 시나리오별로 타당한 박리거동을 보여주었다. 각 시나리오에 따른 구조물의 내하력은 본 논문의 2편에서 산정되었다.

에어컨 화재사례 분석 및 예방대책에 관한 연구 (A Study on the Fire Case Analysis of Air Conditioner and Preventive Measures)

  • 김동욱;이기연;김동우;길형준;방선배;정영식
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.40-45
    • /
    • 2013
  • 전기화재는 다양한 원인에 의해 발생하고 있으며 최근에는 복합적인 원인에 의해 발생하기 때문에 전기적, 열적, 기계적, 환경적 영향에 의한 제품의 열화특성과 발열 메커니즘 등 체계적인 연구와 분석을 통한 과학적이고 합리적인 안전설계애안 제시를 위한 연구가 절실히 요구되고 있는 실정이다. 재해로 인한 인적 물적 손실은 국가와 기업의 대외 신뢰도 하락을 가져오고 있으며 제품 안전에 대한 수요는 무한 경쟁에 따른 규제완화의 이유로 증가하고 있다. 기업의 이미지를 증진시키고 국제적 경쟁력을 강화시키기 위해 제품에 대한 안전 설계는 반드시 필요하다. 본 논문에서는 사용량이 점차 증가하고 있는 에어컨에서 전기화재가 발생한 사례와 원인 및 재현실험을 통해 안전설계에 대한 제시를 위해 수행 하였으며 화재 예방대책 등의 기초 자료로 할용 가능할 것으로 기대한다.