• 제목/요약/키워드: Fire alarm

검색결과 257건 처리시간 0.025초

IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석 (Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권2호
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

디지털 방식 무선 화재알림설비의 신호 패턴 인식기법 적용 (Application of Signal Pattern Recognition Technique of Digital Wireless Fire Alarm System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권5호
    • /
    • pp.14-21
    • /
    • 2022
  • The purpose of this study was to apply the signal pattern recognition technique to the digital wireless fire-alarm system and to reduce unwanted fire alarms. In this study, the fire alarms of the K Institute, which operates the largest digital wireless fire-alarm system in Korea, were classified into normal operations and unwanted fire alarms, and these were analyzed and compared with actual fire signals. In addition, by designing a non-fire signal filter and applying it to the K Institute, we confirmed that the monthly unwanted fire alarm rate of all 5,713 detectors decreased sharply. In particular, the unwanted fire alarm rate for flame decreased from 1.09% to 0.11% and the unwanted fire alarm rate for smoke decreased from 0.65% to 0.035%.

공동주택에서의 화재 경보음 전달특성에 관한 연구 (An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings)

  • 이민주;김명준;윤명오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

Evacuation Safety Evaluation of Tourist Hotels with the Fire Alarm Method

  • Moon, Sung-Chun;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.363-375
    • /
    • 2021
  • The purpose of this study is to analyze the safety of evacuation using the Pathfinder program for the alert at once, the priority alarm method, the priority alarm method for the four floors above, and the sequential priority alarm method, which is a modification of the priority alarm method specified in the tourist hotel building. Currently, in Korea's National Fire Safety Codes (NFSC), fire alarm methods are compulsorily applied differently depending on the number of floors and total floor area of a building. Although the growth rate is getting faster due to the diversification of building structures, it is still an obstacle to improving evacuation safety to comply with the standardized fire alarm method in NFSC. As a result of the experiment, the evacuation time was found to be faster with the priority alarm method for the four floors above than the priority alarm method applied to the specific firefighting object. Compared to the priority alarm method applied to the tourist hotel, which is a specific firefighting target with 5 or more floors and a total floor area of more than 3,000m2, the time was shortened by 3.7 seconds when measured by applying the priority alarm method for the four floors directly above. This indicates that it is necessary to take measures to select a fire alarm method suitable for the structure and environmental conditions of the building rather than applying the uniform NFSC regulations.

공동주택 화재 경보음 전달특성과 개선방안 고찰 (An Study on the Sound Attenuation and the Improvement in Hearing Condition of Fire Alarm Device in Apartment Buildings)

  • 이민주;윤명오;김명준
    • 한국소음진동공학회논문집
    • /
    • 제16권6호
    • /
    • pp.593-601
    • /
    • 2006
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10 dBA. To give the minimum sound level 60 dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선 (Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver)

  • 지승욱;김시국;양승현;이재진;김필영;이춘하
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

공장소음으로 인한 화재 경보음 인지 영향정도에 관한 연구 (A study on Noise Generation and Awareness of the Fire Alarm Sound in the Factory)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.97-103
    • /
    • 2015
  • The people who are in the noise factory are difficult to hear and recognize about fire and to evacuate quickly when a fire occurs. This study was conducted to analyze workplace's background noise of 31 factories in Incheon and to know the workplace noise level comparing to fire alarm sound level. The measured average noise level was 96.8dB(A). Noise level of measured result was exceeded as 6.8dB(A) comparing to NFSC (National Fire Safety Code) noise level of 90dB. NFPA suggests that when background noise exceeds 85dB or more than that, other methods should be considered to know alarm sound. Also fire alarm sound should exceed more than 15dB(A) comparing to background noise level. Therefore it was concluded that the design of the fire alarm systems should not be applied to the workplace without considering background noise and it needs to be improved with regulations and the systems.

공동주택 화재경보 발생음 특성에 관한 실험연구 (Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings)

  • 이민주;강희혁;권봉석;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구 (The study of Connection Emergency lantern with Fire Alarm System)

  • 전중함;이상화;권오수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF