• Title/Summary/Keyword: Fire Type

Search Result 1,102, Processing Time 0.029 seconds

Comparative Analysis of Preparation Time between Rack-type and Reel-type Fire Hoses (호스걸이형 소방호스와 호스릴 소방호스의 전개시간 비교 분석)

  • Hong, Suk-Hwan;Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.49-53
    • /
    • 2021
  • The objective of this study was to understand which type of fire hose should be placed in indoor fireplug box upon analyzing the preparation time between rack-type fire hose and reel-type one. With respect to the type of hose, rack-type stacking method was used and hose preparation time was measured with 5 times of repeat test, separating men and women. Study results reveal that preparation time of reel-type fire hose took longer than that of rack-type one in both men and women. For both rack-type hose and reel-type hose, preparation time by two persons took shorter than that by one man. Also, preparation time by three persons took shorted than that by two women. Preparation time for both rack-type hose and reel-type one by men took shorter than that by women. In summary, it was confirmed that rack-type hose could be prepared within shorter time than reel-type one. Since the size of drum set in the reel-type fire hose is relatively small, it had some difficulty in preparation of fire hose timely.

Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver (재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

A Study on the Classification of Domestic Fire Detector using Response Time Index (반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구)

  • Hong, Sung Ho;Kim, Dong Suck;Choi, Ki Ok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

How to Reduce Fire Fatalities in Residential Occupancies on the Way to a Rapidly Aging Society?

  • Sekizawa, Ai
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2006.04a
    • /
    • pp.29-40
    • /
    • 2006
  • Everybody may be vulnerable to fires depending on the time, place, and circumstances. Fire statistics show that the occurrence of fire death depends not only on the severity of a fire itself, but also largely on the conditions of occupants such as physical functions, the environment around occupants, and the type of facility where are fire occurs. The review of fire safety from the viewpoint of vulnerable populations does not simply mean additional special attention and care only to high risk groups, but instead it means significant review of fire safety design and systems for all people from a more universal standpoint. Therefore, in order to examine the strategies of a fire death-reduction program, safety measures suitable for the relevant high-risk groups considering the type of vulnerable person, the type of fire, and the type of building in residential occupancies. Solutions will require strenuous multilateral effort and flexibility.

  • PDF

A State-of-art of Experimental Research and Calculated Models of Dowel-type Timber Connections in Fire

  • Luo, Jing;He, Minjuan;Li, Zheng
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.285-297
    • /
    • 2021
  • Fire safety is one of the most significant issues for the design of mid-rise and high-rise timber structures. A large number of experimental tests were conducted during the last three decades to investigate the fire performance of the dowel-type timber connections. Many influenced parameters (e.g. the thickness of the side timber, the load ratio, the fasteners type etc.) were considered in those experiments. Relevant calculated models were proposed by previous researchers to estimate the fire resistance of the connections. In this study, a series of experimental programs of dowel-type connections in fire are collected. Then, empirical formulas proposed by EN 1995-1-2, Fire safety in timber buildings, and previous researchers are presented and analyzed. The accuracy of those formulas is checked by comparisons between the experimental data and estimated results. The collected experimental research and empirical formulas can be used as the reference for the fire design of dowel-type timber connections in the future.

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

Study of Aerial Fire Line Construction and Suppression Method on Forest Fire (산불 공중진화 방화선 구축형태 및 진화방법에 관한 연구)

  • Bae, Taek-Hoon;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.26-31
    • /
    • 2010
  • In this study, attack process and aerial control line construction type which were considered forest fire type and a case of operations were suggested using the experience of aerial fire attack of all type of forest fires. As the spread rate of forest fire is effected by terrain, slope, wind speed, forest species and etc., we needed to analyze spreading direction, behavior type and intensity before heli-team constructed a aerial control line. Especially, It is important to consider safety of attack team as a their views were obstructed. In this study, we suggested a 13 methods from type A to type M about attack and construction of aerial indirect control line.

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

A Study on the Response Characteristics of Fire Detector by Full-scale Experiment of Fire Phenomena in the Row House (주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.67-72
    • /
    • 2009
  • This paper is for response feature of fire detectors not only to analysis response feature of fire detector, but also to observe flame spread of inside-building and fire enlargement by using the row house which is supposed to be broken up. Many kinds of popular detectors such as heat type detector(differential type, fixed temperature type, Analogue type)and smoke type(light scattered type, Analogue type, single alarm type) were installed in the house in order to check for the change of temperature by installing of thermocouples. As a result, smoke detectors are better than heat detectors when it comes to making effective fire-detect system in the row house.

A Study on the Facility Layout and Signal-fire Stand of Border Signal-fire in Chosun Dynasty (조선시대 연변봉수(沿邊烽燧)의 배치형식 및 연대(煙臺)에 관한 연구)

  • Lee, Chul-Young;Yoon, Jae-Woong
    • Journal of architectural history
    • /
    • v.15 no.5
    • /
    • pp.41-56
    • /
    • 2006
  • Signal fire was a communication system which deliver urgent news by smoke and light. It informed the condition of the border to the central government and the military base rapidly. This research was to analyze the border signal-fire which is the main facility of military protective duty for safety of sea side in chosun dynasty. The results of this research were described separately as follows. 1. The border signal-fire has three types of facility layout, The majority was one-site, near two-site, separate type. The majority was near two-site type. 2. Plan configuration of signal-fire stand which is separated with circle, oval, round-rectangular and rectangular type roughly was constructed with circle type generally. Four types of signal-fire stand was observed in southern and western sea side impartially. However, in eastern side, circle type of signal-fire stand was mainly found. Therefore, regional characteristics could be considered partially. 3. The height of signal-fire stand was about 8~10m. The diameter of combustion chamber on the signal-fire stand was 2~3m in circle type, and the dimension of rectangular type was about $1.9{\times}1.9{\sim}3.2{\times}3.0m$. 4. Building base that protect ground moisture and infilteration of rainfall was found in 10 border singal-fire, the height of it was about 0.3m~2.5m.

  • PDF