• Title/Summary/Keyword: Fire Tracking

Search Result 124, Processing Time 0.032 seconds

A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine (건조일체형 드럼세탁기의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

Cause Analysis and Countermeasure of Tracking in Mobile Phone Charger (휴대폰 충전기 내 트래킹 발생 원인 분석 및 대책)

  • Park, Jin-Young;Kim, Jae-Hyun;Park, Kwang-Muk;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.71-77
    • /
    • 2016
  • The electrolyte of the capacitor in mobile phone chargers leaks to the power input terminal resulting in tracking on the PCB board to form a carbonized conductive path. As a result of structural analysis of the cause of the tracking, It occurred when the power input terminal and the PCB board were connected directly using the connector. The larger the amount of electrolyte leaked from the capacitor into the power input terminal, or the lower the height of the partition provided between the plug pins of the power input terminal, the higher the tracking occurrence rate. Accordingly, to lower the occurrence rate of tracking in the charger, it is necessary to provide a partition on the capacitor or increase the height of the partition provided on the power input terminal so that the leaked electrolyte does not flow to the power input terminal. In addition, the tracking occurrence rate will be reduced further if the shape of the PCB board touching ther power connection terminal is changed to ${\Pi}$.

Examination on the Mounting Status of Cigar Lighter Receptacle for Vehicles and Analysis of its Tracking Characteristics (차량용 시가 잭의 장착 실태조사 및 트레킹 특성 분석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.28-33
    • /
    • 2009
  • This study examined the mounting status of cigar lighter receptacles for vehicles and analyzed the tracking phenomenon that occurs when foreign material entered a cigar lighter receptacle to obtain data for the analysis of accident investigation. Regardless of the vehicle's output, cigar lighter receptacles are mounted in a vehicle horizontally, vertically, or at tilting or inclined angle. The tilting type cigar lighter receptacle is much easier to use but current leakage resulting from foreign materials (coffee, beverages, water, etc.) falling into the cigar lighter receptacle may cause a fire to start. This study used a vehicle battery (DC 12V) as a power supply for the tracking test and configured its circuit in the same way as that of an electrical device in a vehicle. The tracking phenomenon that occurred in the standby mode of the vehicle exhibited a fine flame and an irregular occurrence of smoke. While this tracking phenomenon was occurring, the leakage current and the reaching distance of the flame were measured to be approximately 930mA and $20{\sim}50cm$, respectively. It is thought that the resultant flame may ignite toluene, dust, cigarettes, etc. It was observed that as the tracking progressed, the internal metal socket melted and a hole was created, the surface of which was also severely carbonized. In addition, the electrical resistance of the carbonized conductive path was measured to be approximately $30{\Omega}$. It is thought that this much resistance may cause local heating when leakage current flows and could ignite any nearby flammable material.

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF

A Study on the Tracking Characteristic Depending on Live Part Form on the Plug (플러그 충전부 형태에 따른 트래킹 특성에 관한 연구)

  • Sim, Sang-Bo;Jee, Seung-Wook;Oh, Sae-Byeol;Kim, Si-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.27-30
    • /
    • 2011
  • 본 논문은 플러그 충전부 형태에 따른 트래킹 발생특성을 분석하고자 현재 국내에서 시판되고 있는 플러그 중 형태가 서로 다른 플러그들을 시료로 선정하여 충전부간 거리에 따른 트래킹 특성을 KS C IEC 60112에 의거하여 실험을 실시하였다. 또한 모형 트래킹 실험장치를 제작하여 염해환경에서의 플러그 충전부간 트래킹 특성을 관찰하였고, 플러그에 가해지는 전압은 수전설비의 변압기 결선 형태에 주로 사용되는 단상 3선식과 단상 2선식의 형태로 인가하여 결선 형태에 따른 위험성을 추가적으로 분석하였다.

  • PDF

A study on the detection of poor contact and arcing fault using a fuzzy logic (퍼지논리를 적용한 전기적 접촉불량 및 아크 검출에 관한 연구)

  • Kim, Hyun-Woo;Kim, In-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.205-210
    • /
    • 2007
  • This study on the prevention of electric fire. Generally the electric fire is caused by break or disconnection of the power line, short circuit and poor contact, arcing fault ect. In these causes, this paper is studied on the detection of poor contact and arcing fault. The arcing fault is caused by poor contact mainly. The arcing fault can occurs a electric fire by interaction of flammable gas and materials and it can be caused of tracking and carbonization. These phenomenons is also caused of electric fire. Therefore this paper is studied on the detection of arcing fault and poor contact.

  • PDF

Development of Gun Fire Control System for the FFX-I Program (차기호위함 전투체계용 함포 사격제원계산장치 개발)

  • Suh, Tae-Il;Kim, Eui-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.752-761
    • /
    • 2013
  • A new gun fire control system has been developed for the Korean next generation frigate class. The engineering requirement was far more tightened than the PKG-A class for the firing range availability and gun control function since 5 inch gun is adopted for the new ship. We mention about the principal technologies required to build a generic gun fire control system and proposed methods for the new gun fire control system. The new system has been designed based on the proposed methods in order to satisfy the requirement and functionality has been proved to be acceptable through the sea trial by Korean navy.