• 제목/요약/키워드: Fire Size

검색결과 632건 처리시간 0.023초

화재의 크기와 종류에 따른 선박 피난 안전 연구 (A Study on Ship Evacuation Safety Consequent on the Size and Sort of Fire)

  • 김원욱;김대희
    • 수산해양교육연구
    • /
    • 제28권5호
    • /
    • pp.1358-1364
    • /
    • 2016
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crewmen are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. According to the ship fire survey, about 50% of the total fire accidents occurred at an engine room, and the main fire origin was analyzed to be oil. In addition, ship fire breaks out in the order of baggage racks and living quarter. In short, the survey indicates that all sorts of fires belonging to A, B, C and D-class have occurred. This study, targeting an actual passenger ship 'A', found the response time to evacuation, during which the people on board a ship recognize the outbreak of fire, and act, and the travel time for evacuation which is the actual travel time. In addition, this study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of passengers and crew based on the collected simulation data by fire size and sort. As a result of the analysis, it was found that when examining the only actual evacuation movement time excepting the response time to evacuation, people are safe by completing evacuation before the effective evacuation time only in case fire size is 100Kw among all sorts of fires. In other words, in case of the outbreak of fire more than 1 MW, it was found to fail to meet evacuation safety regardless of fire size.

선박 거주구역 화재시뮬레이션을 위한 격자크기와 생성방법에 관한 연구 (A Study on Grid Size and Generation Method for Fire Simulations for Ship Accommodation Areas)

  • 김별;황광일
    • 해양환경안전학회지
    • /
    • 제23권7호
    • /
    • pp.791-800
    • /
    • 2017
  • 선박 거주구역에 화재발생 시 화재시뮬레이션 도구를 이용하여 화재확산형상을 실시간으로 예측하고 상황에 따른 적절한 대응방안을 제시할 수 있다면 화재사고로 인한 인명피해를 최소화시킬 수 있을 것으로 예상된다. 그러나 오늘날 화재시뮬레이션은 해석대상공간의 크기와 그리드 개수에 따라 해석을 하는데 있어, 매우 장시간을 필요로 하는 현실적 한계가 있다. 이에 이 연구에서는 화재시뮬레이션 시간단축을 목적으로 선박 거주구역 화재시뮬레이션에 적용할 수 있는 격자크기와 생성방법에 대한 연구를 수행하였다. 연구결과 선박 거주구역에 적용되는 격자크기는 0.25[m] 이내의 값을 사용하는 것이 가장 효율적인 것으로 판단되었다. 또한 single mesh 격자생성방법으로 수행했을 경우와 비교하여, multi mesh 격자생성방법으로 시뮬레이션을 수행하였을 때 가시거리 값은 4.3 %, 온도 값은 8.3 % 이내에서 유사하고 해석시간은 약 80 % 감소하였기 때문에, multi mesh 방법으로 격자를 생성하는 것이 해석시간을 단축하는데 있어 매우 효과적임을 확인하였다.

단면크기 및 피복두께 변화에 따른 철근콘크리트 기둥의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performance of the Reinforced Concrete Columns According to the Cross Section Size and Depth of Concrete Cover)

  • 조경숙;여인환;조범연;김흥열;민병렬
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.78-84
    • /
    • 2011
  • 최근 콘크리트 내화 연구는 대부분 고강도 콘크리트의 내화성능 확보에 많은 초점이 맞추어져 있다. 그러나 국내의 콘크리트 수요를 살펴보면 40MPa 이하의 일반강도 콘크리트의 수요가 전체 콘크리트 수요량의 대부분을 차지한다. 따라서 고강도 콘크리트의 내화성능에 대한 연구뿐만 아니라 일반콘크리트의 내화성능에 관한 연구도 필요하다. 본 연구에서는 40MPa 콘크리트 기둥을 대상으로 콘크리트 피복 두께와 단면크기를 변수로하여 내화성능을 평가하였으며, 연구 결과 단면크기가 커질수록, 피복두께가 두꺼워질수록 내화성능은 향상되는 것으로 나타났다.

FDS를 이용한 실내화재 모사의 문제점 II. 벽면형 및 모서리형 화재 (A Numerical Study of a Room Fire for Fire Sizes II. wall fire and corner fire)

  • 고경찬;박외철
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.9-13
    • /
    • 2004
  • To confirm the previous finding that FDS predicts a fire growth rate too rapid compared with an experiment in a center fire in a room with an opening, the same computational fluid dynamics was applied to two types of fires, wall fire and comer fire. First the grid size was chosen to eliminate possible numerical errors due to a coarse grid system. Then the two types of fires were simulated for three different fire sizes, 7.65, 21.25, and 51.57kW for each type, which are the same as in the experiment to be compared with. The fires were predicted to grow too fist although the average temperatures and heights of the neutral planes were in good agreement with measurement.

FDS를 이용한 대규모 건축물 화재 시뮬레이션의 격자크기 선정 (Selection of Grid Size in Fire Simulation for Large Scale Buildings by Using FDS)

  • 박외철
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.67-72
    • /
    • 2012
  • 대규모 건축물의 화재 시뮬레이션에 사용되는 FDS의 적정 격자크기를 제시하기 위해 3개의 개구부가 있는 $20{\times}10{\times}3m^3$ 크기의 실과 $44{\times}48{\times}10m^3$ 크기의 클린룸에 대한 화재 시뮬레이션을 수행하였다. z방향 격자크기를 0.2 m로 고정하고 x, y방향의 격자크기 0.1~1.0 m(종횡비 0.5~5.0)에 대한 온도와 가시거리의 변화를 비교하였다. x, y방향 적정 격자크기는 0.5 m(종횡비 2.5) 이내이며, 1.0 m의 경우에는 오차가 큰 것으로 나타났다. 온도, 가시거리 등의 변동으로 인해 유효피난시간의 산정에 주의가 요구되고, 불가피하게 큰 격자를 사용해야하는 경우에는 격자크기에 대한 검토가 필요하며, 더 큰 격자를 사용하기 위해 격자의 종횡비에 관한 추가연구가 필요함을 확인하였다.

고층건축물 수직공간의 화재 시 압력차 분석을 위한 실험적 연구 (An Experimental Study on the Analyze the Pressure Difference in case of Fire in Vertical Space of High-Rise Buildings)

  • 허예림;김혜원;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2020
  • As buildings in South Korea become more skyscrapers, the risk of fire is also emerging. Thus, regulations, regulations, and guidelines are being improved to prevent the spread of smoke in the event of a fire in high-rise buildings, but research on smoke flow and pressure distribution in vertical spaces is insufficient. Therefore, in this study, the temperature of each floor in the vertical space according to the size of the fire is measured through the miniature model experiment, and the pressure difference is calculated to establish the basic data for the improvement of the performance of domestic air supply facilities in the future. Thus, a scale model of one-sixth the size of the actual building was produced to measure the temperature, and the pressure difference was derived by substituting the value for the expression. The pressure difference varies depending on the size of the cause of the fire, and it is believed that the differential pressure and conditions of the building should be taken into account before calculating the supply volume for the analysis of the pressure difference according to the size of the cause of the fire in the event of fire.

  • PDF

재래시장의 화재확산 방지를 위한 수막설비 설치 지침 (The Water Curtain Installation Guideline for Fire Spread Prevention in Market)

  • 최정욱;조성우
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

결절법을 이용한 전영역에서의 연기입자 응집체에 대한 브라운응집현상 해석 (Simulation of the Brownian Coagulation of Smoke Agglomerates in the Entire Size Regime using a Nodal Method)

  • 구재학
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.681-691
    • /
    • 2011
  • The size distributions of smoke particles from fire are prerequisite for the studies on fire detection and adverse health effects. Above the flame of the fire, coagulation dominates and the smoke particles grow from 1 to 50 nm up to 100 to 3,000 nm, sizes ranging from the free-molecular regime to the continuum regime. The characteristics of the agglomeration of the smoke particles are well known, independently for each of the free-molecular and continuum regimes. However, there are not many systematic studies in the entire regime by the complexity of the mechanisms. The purpose of this work is to find the characteristics of the development of the size distribution of smoke particles by agglomeration in the entire size range covering the free-molecular regime, via transition regime, to the near-continuum and continuum regime for each variation of parameters such as fractal dimension, primary particle size and dimensionless coagulation time. In this work, the dynamic equation for the discrete-size spectrum of the particles was solved using a nodal method based on the modification of a sectional method. In the calculation, the collision frequency function for the entire regime, which is derived by using the concept of collision volume and general enhancement function, was applied. The self-preserving size distribution for the entire regime is compared with the ones for the free-molecular or continuum regimes for each variation of the parameters.

다양한 화재조건에서 플라스틱 종류에 따른 연기입자의 크기분포 변화 측정 (Measurement of the Size Distribution of Smoke Particles with Plastic Types Under Various Fire Conditions)

  • 구재학;황철홍
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.8-15
    • /
    • 2017
  • 화재발생 시에 대부분의 인명 피해는 연기에 의해 발생되는데, 최근 건축 내장재에서 차지하는 플라스틱의 양이 많아지며 발생되는 연기의 유독성이 점차적으로 증가되고 있다. 연기에 의한 인체피해의 상당부분은 흡입연기의 폐침전과 관련이 있으며, 연기입자의 크기분포는 폐침전 특성에 직접적인 영향을 미친다. 따라서 플라스틱 종류에 따른 연기입자의 크기별 발생량 검토는 폐침전에 의한 인체피해 연구에 필수적으로 요구된다. 최근의 목재와 폴리프로필렌(PP)에 대한 연기입자의 발생특성 연구에서 PP의 연기입자 크기분포 특성이 몇 가지 측면에서 목재와는 확연히 다르게 나타났다. 이에 따라, 본 연구에서는 다른 플라스틱들도 연기입자 크기분포에서 PP와 같은 특성을 보이는지 알아보기 위해서 대표적인 4가지 플라스틱(LDPE, PA66, PMMA, PVC)에 대하여 연기입자 크기분포 측정실험을 수행하였다. 특정 조건에서 연소생성물을 균일하게 생성하고 분석하기 위하여 ISO/TS 19700 기준에 따른 등속튜브연소로를 이용하여 연소로의 온도와 산소공급량에 따라 다양한 화재조건에서 연기입자를 균일하게 발생시키고, 정전저압 임팩터를 사용하여 연기입자의 크기에 따른 개수농도를 실시간으로 측정하였다. 실험 결과 4가지 플라스틱의 연기입자 크기분포 특성은 여러 측면에서 PP와 유사하며 목재와는 확연히 다르게 나타났다.

국내 성능위주설계의 시행현황 분석 - 화재시나리오 및 시뮬레이션을 중심으로 (Analysis on the Implementation Status of Domestic PBD (Performance Based Design) - Focusing on the Fire Scenario and Simulation)

  • 안성호;문선여;류일현;최준호;황철홍
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.32-40
    • /
    • 2017
  • The current status of Performance-Based Design (PBD) implemented in 4 wide areas (Seoul, Gyeonggi, Incheon and Busan) over the past 5 years was reviewed with regard to the number of PBD implementation and target buildings. Then, detailed status related to fire scenarios, input information for fire simulation, and grid size were analyzed with the pre-review for the PBD. As a result, the domestic PBD was mainly applied to the mixed occupancy. In the fire simulations performed on the identical fire scenario and fire space, the maximum heat release rate (HRR) varied significantly depending on the PBD designer. Various combustibles were also considered for the identical fire source, and their combustion properties also showed considerable uncertainty. In addition, the applicability of accurate input information for predictive models of heat and smoke detectors was examined. Finally, the average grid size for the fire simulation using Fire Dynamics Simulator (FDS) was analyzed, and the improvement of PBD to minimize designer dependency was proposed.