• Title/Summary/Keyword: Fire Simulation

Search Result 1,021, Processing Time 0.028 seconds

Analysis on the Impact of Draft Curtains on Hospital Building Fires

  • Xiaopei Liu;Hasung Kong
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.367-375
    • /
    • 2024
  • Draft curtains are an important tool to reduce the spread of fire smoke in buildings. This paper mainly studies the influence of draft curtains on smoke spread in a hospital outpatient building with a spacious hall. The outpatient building of a county hospital in China is taken as the research object, and a fire simulation model is established based on PyroSim software. Four scenarios are designed: no draft curtains in the hall, draft curtains with a length of 1.5m in the hall, draft curtains with a length of 2.0m in the hall, and draft curtains with a length of 2.5m in the hall. At the same time, considering the worst situation, only the main emergency exit is opened, while the remaining emergency exits and windows are all closed, and the fire-fighting facilities are not activated. The detection point is set at the open emergency exit, 1.8m above the ground. Through the simulation of four scenarios, the effect of draft curtains on smoke spread is discussed from four aspects: smoke layer height, temperature, visibility, and CO concentration. The results show that draft curtains have a significant impact on the spread of smoke in a hospital outpatient building with a spacious hall. The longer the draft curtains are, the better the smoke-blocking effect. It should be noted that in the actual design, the length of the draft curtains should be considered without affecting the evacuation of personnel.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

A Numerical Analysis for Fire Spread Mechanism of Residential Building Fire (주거용 건축물의 화염전파 현상에 대한 수치해석적 검토)

  • Ahn, Chan-Sol;Kim, Heung-Youl;You, Yong-Ho;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • This study is intended to present a computational thermal model for a residential building. As the Performance Based Design is more popular, fire-intensity and fire-load have turned out to be very important factors for building design and can be predicted through some computational work. To predict and estimate the fire properties of a residential fire, we made some numerical models of combustibles and residential building. In a bid to validate the estimate values, computational analysis results from numerical models were compared with real fire tests. For computational analysis, the Fire Dynamics Simulator (FDS) was used with Large Eddy Simulation (LES) model for turbulence. Consequently, fire-intensity was well predicted and flash-over of rooms were successfully estimated.

Effects of Geological Structure and Tree Density on the Forest Fire Patterns (지형구조와 나무밀도가 산불패턴에 미치는 영향)

  • Song, Hark-Soo;Kwon, Oh Sung;Lee, Sang-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.4
    • /
    • pp.259-266
    • /
    • 2014
  • Understanding the forest fire patterns is necessary to comprehend the stability of the forest ecosystems. Thus, researchers have suggested the simulation models to mimic the forest fire spread dynamics, which enables us to predict the forest damage in the scenarios that are difficult to be experimentally tested in laboratory scale. However, many of the models have the limitation that many of them did not consider the complicated environmental factors, such as fuel types, wind, and moisture. In this study, we suggested a simple model with the factors, especially, the geomorphological structure of the forest and two types of fuel. The two fuels correspond to susceptible tree and resistant tree with different probabilities of transferring fire. The trees were randomly distributed in simulation space at densities ranging from 0.5 (low) to 1.0 (high). The susceptible tree had higher value of the probability than the resistant tree. Based on the number of burnt trees, we then carried out the sensitivity analysis to quantify how the forest fire patterns are affected by the structure and tree density. We believe that our model can be a useful tool to explore forest fire spreading patterns.

A Comparative Study on the Toxicity Evaluation for Fire Smoke by FDS (FDS를 이용한 화재시 연소가스의 독성평가에 관한 비교 연구)

  • Jeong, Beom Jin;Lee, Keun Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • FDS (Fire Dynamics Simulator) is the most widely used computational fluid dynamics software in the fire safety engineering community, and it is applicable to various evaluations of fire growth and its effects. This study made use of a range of outputs from FDS simulation to predict FED (Fractional Effective Concentration) and FEC (Fractional Effective Concentration) levels which are often adopted to evaluate toxicity of fire smoke. As it is not possible to calculate these values directly from outputs of FDS, it was necessary to produce them by means of additional calculation procedures incorporating results of evacuation simulation. In this study, the latest version of FDS, which was recently updated in November 2013, was utilized for the purpose of quantitative comparison with the old version of FDS. As a result, it was found that they make about 10 percent difference on average in predicting FED and FEC levels for the cable fire case study.

Revision of the Input Parameters for the Prediction Models of Smoke Detectors Based on the FDS (FDS 기반의 연기감지기 예측모델을 위한 입력인자 재검토)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.44-51
    • /
    • 2017
  • Accurate predictions of the activation time for smoke detectors using a fire simulation is are required to ensure the reliability of the RSET (Required Safe Egress Time) calculation in the process of PBD (Performance-Based Design). The objective of this study was to enhance the accuracy of input parameters for the numerical models of smoke detector based on the FDS. To this end, a Fire Detector Evaluator (FDE) developed in previous studies was improved. The uniformities of flow and smoke inside the FDE were improved and accurate measurements of the obscuration per meter (OPM) related to detector operation were also performed through a decrease in the forward scattering of smoke particles. The input parameters using the improved FDE showed a significant difference from the previous FDE quantitatively. In particular, a larger difference was found in a photoelectric detector compared to an ionization detector. Considering that the operating conditions of smoke detectors are affected by the detector type, combustibles, smoke particulars, and color, the database (DB) on the input parameters for various detectors and combustibles should be built to improve the reliability of PBD in future studies.

The Study of fire Driven flow and Smoke Exhaust Efficiency for PSD Installation Subway Station (PSD 설치역사의 화재유동 및 배연 효율 연구)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Kim, Hag-Beom;Kim, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1054-1061
    • /
    • 2009
  • This research was performed with emphasis on fire driven flow behavior and smoke exhaust efficiency which depend on the presence of PSD which are being installed domestically and overseas. For simulation, Jung-ang-ro station of Dae-gu subway station was chosen as model, and fire driven flow analysis was performed by using FDS as flow analysis code. Since many calculation time are required for calculation due to increase in the number of grid as the entire station is modeled, simulation was conducted in parallel processing technique. The fire driven flow analysis was analyzed case by case with composing fire scenario to compare fire driven flow and smoke exhaust efficiency changes depending on the presence of PSD. For fire scale, fire strength of 10MW was studied by referring to NFPA-l30. The calculation results were analyzed with focus on passenger safety by referring to NFPA-130.

  • PDF

The Transfer Characteristics of $CO_2$ Extinguishant According with the Location of Fire Plume (화재위치에 따른 $CO_2$소화제 전달특성)

  • 박찬수;최주석
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2003
  • To analyze the transfer characteristics of $CO_2$ extinguishant when extinguishant is injected into a closed space similar to a marine engine room, a numerical simulation was performed. Flow and Concentration fields are calculated according with the variation of the fire plume,s location. The results show that tile variation of fire plumes, location greatly effected on the flow patterns and the characteristics of $CO_2$ extinguishant transfer. In case of the fire plume located at left region of the 2nd floor center in the engine room consisted of first and second floor, The effects similar to the air curtain is found and cut off the mass transfer. In the characteristics with hight, the iso-concentration line below the extinguishable limit is formed in the left region of the 1st and 2nd floor center after the $CO_2$ extinguishant is completely injected. therefore I think that the results of this study are considered to arrange the $CO_2$ injection nozzles for the $CO_2$ fire fighting equipments.

Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel (중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.9-17
    • /
    • 2016
  • In the case of a medium length road tunnel, the installation of a smoke control facility is not mandatory so users can suffer considerable injuries if a fire breaks out. Therefore, this study analyzed the high-temperature air and toxic gas generated by fire proliferating with time when a smoke barrier is not installed and when the installation interval is 100, 150, 200, and 250 m through 3-dimensional numerical analysis, evacuation simulation, and Quantitative Risk Assessment Methodology targeting the medium length road tunnel. As a result, the diffusion of the high-temperature air and toxic gas occurring from the a fire was delayed when the smoke barrier was installed in a medium length road tunnel compared to that when it was not installed. In addition, when the installation interval of a smoke barrier was 100m and the numerical analysis target was 100m, the diffusion of high-temperature air and toxic gas generated by the fire was delayed more than in the other cases, which was most suitable for tunnel users to evacuate.

3D finite element analysis of the whole-building behavior of tall building in fire

  • Fu, Feng
    • Advances in Computational Design
    • /
    • v.1 no.4
    • /
    • pp.329-344
    • /
    • 2016
  • In this paper, a methodology to simulate the whole-building behaviour of the tall building under fire is developed by the author using a 3-D nonlinear finite element method. The mechanical and thermal material nonlinearities of the structural members, such as the structural steel members, concrete slabs and reinforcing bars were included in the model. In order to closely simulate the real condition under the conventional fire incident, in the simulation, the fire temperature was applied on level 9, 10 and 11. Then, a numerical investigation on the whole-building response of the building in fire was made. The temperature distribution of the floor slabs, steel beams and columns were predicted. In addition, the behaviours of the structural members under fire such as beam force, column force and deflections were also investigated.