• Title/Summary/Keyword: Fire Services

Search Result 476, Processing Time 0.025 seconds

Prehospital care and knowledge, prehospital care confidence toward the infant and toddlers of the 119 emergency medical technicians (119 구급대원의 영유아에 대한 응급처치 현황 및 응급처치 지식과 수행 자신감 비교)

  • Song, Eun-Hye;Lee, Kyoung-Youl
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.1
    • /
    • pp.19-33
    • /
    • 2015
  • Purpose: The purpose of this study was to improve the quality of prehospital care provided to infants and toddlers (preschoolers) based on questionnaire findings. Methods: A total of 1,634 running sheets from 119 centers of D city from patients older than 1 month and less than 7 years of age from January 1, 2013 to December 31, 2013 were reviewed for 119 emergency medical technicians (EMTs) activity analysis. And a self-reported questionnaire about knowledge and competency in prehospital care of preschoolers was completed by 159 EMTs at fire stations in D city. Data were analyzed using IBM SPSS Statistics for Windows, Version 21.0. Results: Of 1,634 patients, 58.6% were call to 119 due to disease, 33.8% due to injuries and 7.5% due to traffic accident. Knowledge and confidence in treating preschoolers was significantly higher among paramedic EMTs than basic EMTs. The 119 EMTs surveyed indicated that training for preschooler prehospital care was most needed. Conclusion: In order to provide high quality prehospital care for preschoolers transported to emergency rooms, it is necessary to equip ambulances with the proper equipment. In addition, EMTs should be provided educational opportunities and clinical training.

A study on the current status and the obstacles to prehospital spinal motion restriction performed by 119 paramedics to major trauma patients (중증외상환자에 대한 119구급대원의 척추고정 실태 및 장애요인)

  • Park, Jung-Seung;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.89-106
    • /
    • 2020
  • Purpose: This study attempts to improve the status of emergency care for major trauma patients transferred by 119 paramedics by analyzing the status of emergency care and the obstacles to the spinal motion restriction (SMR) for major trauma patients. Methods: A total of 600 rescue logs were collected from major trauma patients transported by 119 paramedics in the C fire department from Jan. 1, 2015, to Dec. 31, 2017. And then, 280 questionnaires were collected from the 119 paramedics in C fire department from May 3 to Jun. 3, 2019. Data were analyzed using SPSS 24.0 version. Results: Among 499 spinal motion restriction adaptive patients, the spinal motion restriction rate was 51.1% (255 individuals). Lack of human resources and quality control problems were among the obstacles to spinal motion restriction. Conclusion: The 119 paramedics should improve their activeness and skills in performing emergency care, and since training and experience are of crucial importance, they should expand various education systematized according to demand.

Local Imbalance of Emergency Medical Services(EMS): Analyses on 119 EMS Activity Reports of Busan (구급서비스의 지역 불균형: 부산시 119 구급활동일지 분석)

  • Lee, Dalbyul
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.3
    • /
    • pp.161-173
    • /
    • 2020
  • This study analyzed local imbalances in the supply and demand of emergency medical services in Busan using the 119 emergency activity reports of the Busan Fire & Disaster Headquarters. The data for EMS activity reports in 2017 was converted into Jimgyegu units. The spatial distribution of the indicators representing the local imbalance of emergency demand and supply (number of reports, number of reports relative to the population, average coefficient of variation and outlier of on-site arrival time, and number of dispatches outside the jurisdiction) was analyzed using Hotspot analysis of GIS spatial statistics analysis. As a result of the analysis, the hot spot area and the cold spot area where both supply and demand of emergency services are concentrated were clearly distinguished. This means that the supply and demand of emergency services in Busan are locally unbalanced. In particular, there was a difference in the demand and supply of emergency services in the original downtown and its surrounding areas, and in the outskirts of Busan.

Prevention for the elderly safety issues to prepare for an aged society (고령화사회대비 노인안전사고 예방방안)

  • Moon, Gee-Sik;Choi, Jung-Kweon;Park, Hee-Jin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.2
    • /
    • pp.71-84
    • /
    • 2008
  • The usual reasons for elderly safety accidents include lack of care for disaster, physical disability, and an error of judgment and so on. But it is true that accidents will occur continuously with the afore-mentioned causes. Against the elderly safety accidents, safety is the main prerequisite for leading the successful and easy life in the elderly. Therefore, this study is purposed to provide the way of thinking about elderly safety issues by suggesting the methods and contents of education program. This study is specifically focused on developing audio-visual materials involved in all the safety accidents and researching the effect of safety education ability through materials with a view to identify the substantial problems. Education program should make a continuous and long term study so that the curricula of the safety accidents prevention education can be done systematically.

  • PDF

Performance for Geothermal Heating & Cooling System by Heatpump in Office Building (사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가)

  • An, Hyung-Jun;Baek, Sung-Kwon;Cho, Chung-Sik;Sohn, Byung-Hu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF

A Study on Fire Fighting Equipment Organization of Cheju-Do (제주도 소방조직 발전에 관한 연구)

  • Go, Jae-Mun;Kim, Tae-Min;Kim, Hyo-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.2 no.1
    • /
    • pp.47-57
    • /
    • 1998
  • Today, Korean Disaster Control System has better change the existed it for substantial prevention and the emergency control system. And it requires the new National Wide Disaster Control System through building up the cooperation system with related posts which are scattered over the National Administration and one-way management for disaster affairs by them. Therefore 119 that might have a lot of technical knowhow should be a center of disaster affairs which will be able to take all rescue, relief(first aid), fire fighting, and preventive affairs. Then it could be a service organization of citizen. Consequently, it will strengthen National Disaster Control ability and it could be a National Wide Disaster Organization which is ready for prevention, preparation, confrontation of all kinds of disasters with absolute reliance by the citizen.

  • PDF

Thermal Conductivity Measurement of Grouting Materials for Ground Heat Exchanger Borehole (지중 열교환기 보어홀 그라우팅 재료의 열전도도 측정)

  • Sohn, Byong-Hu;Shin, Hyun-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.493-500
    • /
    • 2006
  • This paper concerns the measurement of thermal conductivity of grouting materials for ground loop heat exchanger. A thermal conductivity meter, QTM-500 based on modified transient hot wire method was used to measure the thermal conductivity of neat bentonite and mixtures of bentonite and various additives. Relative to the total mixture mass, as the percent additive was increased the mixture thermal conductivity increased. For the bentonite-silica sand mixtures, the higher density of the sand particles resulted in much higher mixture thermal conductivity. The quartzite and silica sands produced the largest increases in mixture thermal conductivity, while common masonry and limestone sands produced lower thermal conductivity increases.

Performance Evaluation of a Smart CoAP Gateway for Remote Home Safety Services

  • Kim, Hyun-Sik;Seo, Jong-Su;Seo, Jeongwook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.3079-3089
    • /
    • 2015
  • In this paper, a smart constrained application protocol (CoAP)-based gateway with a border router is proposed for home safety services to remotely monitor the trespass, fire, and indoor air quality. The smart CoAP gateway controls a home safety sensor node with a pyroelectric infrared motion sensor, a fire sensor, a humidity and temperature sensor, and a non-dispersive infrared CO2 sensor and gathers sensing data from them. In addition, it can convert physical sensing data into understandable information and perform packet conversion as a border router for seamless connection between a low-power wireless personal area network (6LoWPAN) and the Internet (IPv6). Implementation and laboratory test results verify the feasibility of the smart CoAP gateway which especially can provide about 97.20% data throughput.

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.