• Title/Summary/Keyword: Fire Safety Test

Search Result 543, Processing Time 0.022 seconds

Perception and Work Performance of Patient Safety among Nurses Working in Long-term Care Hospitals (요양병원 간호사의 환자안전인식도와 업무수행도 비교)

  • Moon, Ok Nyun;Kim, Young Im;Geun, Hyo Geun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.25 no.2
    • /
    • pp.118-129
    • /
    • 2016
  • Purpose: This study aims to examine the levels of the perception and work performance of patient safety based on the healthcare accreditation criteria among long-term care hospital nurses. Methods: A cross-sectional study was performed using questionnaires. Out of 205 criteria, 39 items relevant to patient safety were selectively adapted for this study. Data were analyzed with descriptive statistics, t-test, ANOVA, and Pearson correlation coefficient. Results: The mean scores of perception and work performance were 4.36 and 4.24 out of 5, respectively, and the difference between them was significantly different (t=5.78, p<.001). The two variables were both significantly higher among those nurses who were older, married, head nurses, had many nursing experiences, and aware of Healthcare Accreditation than the other nurses. Positive correlations were observed between perception and work performance in all three sub-systems. The relations between these two in the patient care system was the most highly correlated (r=.894, p<.001). The lowest scores of perception and work performances were fire-related criteria (i.e., reporting). Conclusion: Overall, subject's perception proves to be higher than their work performance. It is necessary to develop some viable environment and training programs to enhance their work performance up to the level of their perception of patient safety.

Evaluation of Ignition Performance of Green Hypergolic Propellant (친환경 접촉점화 추진제 점화 성능 평가)

  • Sunjin Kim;Minkyu Shin;Jeongyeol Cha;youngsung Ko
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • Hypergolic propellants, which can ignite themselves without an ignition source, are difficult to handle due to their corrosiveness and toxicity. Therefore, it is necessary to develop green hypergolic propellants with little or no toxicity. In this study, basic research on green hypergolic ignition propellants was conducted. With 95% hydrogen peroxide as an oxidizer and CNU_HGFv1 as a fuel, ignition and combustion characteristics of propellants were evaluated through a drop test, an ignition test, and a combustion test. As a result of the drop test, the ignition delay time was 9.7 ms. It was 27 ms in the ignition test, which was fast enough to be used as a propellant. As a result of the combustion test, a combustion efficiency of 95.4~98.1% was achieved at about 11.7 bar. It was confirmed that fast and stable combustion was possible without hard start or combustion instability.

Test and estimation of ballistic armor performance for recent naval ship structural materials

  • Shin, Yun-ho;Chung, Jung-hoon;Kim, Jong-Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.6
    • /
    • pp.762-781
    • /
    • 2018
  • This paper presents the ballistic armor performance examination and thickness estimation for the latest naval ship structure materials in the Republic of Korea. Up to date, research regarding methods of ballistic experiments establishing database on the latest hull structure materials as well as a precise method of estimating required thickness of armor against specific projectiles have been rarely researched. In order to build a database and estimate proper thicknesses of structure materials, this study used four structure materials that have been widely applied in naval ships such as AH36 steel, AL5083, AL5086, and Fiber Reinforced Plastics (FRP). A $7.62{\times}39mm$ mild steel core bullet normally fired by AK-47 gun was considered as a threat due to its representativeness. Tate and Alekseevskii's penetration algorithm was also used to calculate a correction factor (${\alpha}$) and then estimate the armor thickness of naval ship hull structure materials with a given impact velocity. Through live fire experiments, the proposed method performance difference was measured to be 0.6% in AH36, 0.4% in AL5083, 0.0% in AL5086, and 8.0% in FRP compared with the experiment results.

Research on Improvement of Power Control System of Cold & Hot Water Purifier (냉온정수기의 전원 제어 시스템 개선에 관한 연구)

  • Lee, Ki-Yeon;Choi, Chung-Seog;Kim, Dong-Ook;Kim, Hyang-Kon;Kim, Dong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.45-50
    • /
    • 2007
  • In this paper, this paper discusses how to improve the power control system of cold and hot water purifiers, in particular, system protecting device against abnormal voltage. The existing power supply control system came with a protecting device composed of varistor device only for impulse-type surges. Even though the existing system senses surge other than impulse-type, the system can not be protected. Accordingly, a new type of power control system was designed to protect the system from surge and ultimately prevent electricity accidents. The power control system suggested in this paper will be designed to protect the system by sensing input voltage and discontinuing power supply by means of SSR if voltage exceeding set value is sensed. To test the designed system, surge was imposed on the existing system and processes of system failure were experimented before safety of the designed power control system was simulated via P-spice program developed by Orcad in order to examine safety and reliability of the system.

Measurement of Flash Point for Binary Mixtures of 2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane, and Toluene at 101.3 kPa (2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane 그리고 Toluene 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • For the design of the prevention and mitigation measures in process industries involving flammable substances, reliable safety data are required. An important property used to estimate the risk of fire and explosion for a flammable liquid is the flash point. Flammability is an important factor to consider when developing safe methods for storing and handling solids and liquids. In this study, the flash point data were measured for the binary systems {2-butanol + 2,2,4-trimethylpentane}, {2-butanol + methylcyclohexane} and {2-butanol + toluene} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a Stanhope-Seta closed cup flash point tester. A minimum flash point behavior was observed in the binary systems as in the many cases for the hydrocarbon and alcohol mixture that were observed. The measured flash points were compared with the predicted values calculated via the following activity coefficient (GE) models: Wilson, Non-Random Two-Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC) models. The predicted data were only adequate for the data determined by the closed-cup test method and may not be appropriate for the data obtained from the open-cup test method because of its deviation from the vapor liquid equilibrium. The predicted results of this work can be used to design safe petrochemical processes, such as the identification of safe storage conditions for non-ideal solutions containing flammable components.

High Altitude Test Facility for Small Scale Liquid Rocket Engine (소형 액체로켓엔진 고공환경 모사시험 설비)

  • Kim, Taewoan;Kim, Wanchan;Kim, Sunjin;Han, Yeoungmin;Ko, Youngsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.3
    • /
    • pp.73-82
    • /
    • 2015
  • A high altitude test facility which includes supersonic diffuser and ejector has been developed to simulate atmospheric pressure at 25 km using a 500 N class small scale liquid rocket engine. Also high altitude simulation test for the small scale liquid rocket engine was performed to verify the facility's performance. The experimental facility consists of high altitude simulation device, propellants supply system and coolant supply system. Low pressure condition corresponding to about 27 km(0.021 bar) altitude atmosphere was successfully simulated and a small scale liquid rocket engine thrust level was confirmed at the simulated condition by the high altitude test facility verification test.

Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function (데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Seok-Myung;Joo, Nam-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.

Rejection Degree by Fuzzy Significance Probability

  • Choi, Gyu-Tag;Park, Il-Soo;Nam, Hyun-Woo;Moon, Jong-Choon
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.135-139
    • /
    • 2014
  • We propose some properties for fuzzy hypothesis test by fuzzy significance probability. First, we define fuzzy number data and fuzzy significance probability for repeatedly observed data with alternated error term. By the agreement index, we compare fuzzy significance probability with significance level and drawing conclusions the degree of acceptance and rejection by agreement index.

Study on Electrical Properties of Ceramic Coated Al Bus Bar (세라믹 코팅 Al 부스바의 전기적 특성 연구)

  • Baek, Seung-Myeong;Kwak, Min-Hwan;Kwag, Dong-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1647-1650
    • /
    • 2017
  • Bus bars are used in place of cables because they can carry more electrical energy with the same volume of conductors. This paper deals with the electrical properties of ceramic coating material for busbars. A ceramic coated samples were prepared for the electrical properties test. There are two types of samples. One is a sample without degradation, and the other is a sample degraded for 30 days. Four electrical properties tests were carried out in accordance with domestic standards. Four electrical characteristics tests are AC dielectric breakdown, V-t, lighting impulse dielectric breakdown, and discharge arc. Both samples showed excellent electrical properties, and the ceramic coating material is very good insulating materials for bus bar.

A study on the Performance of Hybrid ventilation system in High-rise Apartment Houses (초고층 공동주택의 하이브리드 환기시스템의 성능평가에 관한 연구)

  • Kim, Ok;Park, Chang-Bong;Park, Jin-Chul;Kim, Nam-Gyu;Rhee, Eon-Ku
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.113-118
    • /
    • 2007
  • As the economic living standards are higher, the demands for more comfortable living space are also larger. In the response of this requirements, studies for improving indoor air environment have been conducted. In case of newly-built apartment buildings, the standard for the minimum ventilation to improve their indoor air quality was made. This study analysed the experimental results from the mock-up test of the hybrid ventilation system which is composed of natural and mechanical ventilation.

  • PDF