• Title/Summary/Keyword: Fire Safety Measures

Search Result 328, Processing Time 0.032 seconds

화학공장의 안전성 평가에 관한 고찰

  • Park, Chang-Bok
    • Fire Protection Technology
    • /
    • s.16
    • /
    • pp.28-40
    • /
    • 1994
  • This objective of safety assessment is to determine the acceptability of risks of hazards, or the coping measures, if not acceptable, by identifying and quantifying the risks potentially involved in incidents, with the information of new technology and the disasterous cases.

  • PDF

Derivation of Cause Variables necessary for Electrostatic Fire/Explosion Risk Assessment and Accident Investigation (정전기 화재·폭발 위험성평가 및 사고조사에 필요한 발생원인 변수 도출)

  • Junghwan Byeon;Hyeongon Park
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.9-21
    • /
    • 2024
  • Static-electricity-induced fires and explosions persistently occur every year, averaging approximately 80 and 20 cases annually according to fire statistics provided by the National Fire Agency and industrial accident statistics provided by the Ministry of Employment and Labor, respectively. Despite the relatively low probabilities of these accidents, their potential risks are high. Consequently, effective risk assessment methodologies and accident investigation strategies are essential for efficiently managing static-electricity hazards in fire- and explosion-prone areas. Accordingly, this study aimed to identify the causal variables essential for accident investigations, thereby facilitating risk assessments and the implementation of effective recurrence prevention measures to mitigate static-electricity hazards in fire-and explosion-prone regions. To this end, industrial accident statistics recorded over the past decade (2012 to 2021) by the Ministry of Employment and Labor were analyzed to identify major fire and explosion incidents and related industrial accidents wherein static electricity was identified as a potential ignition source. Subsequently, relevant investigation reports (63 cases) were thoroughly analyzed. Based on the results of this analysis, existing electrostatic fire and explosion risk assessment techniques were refined and augmented. Moreover, factors essential for investigating electrostatic fire and explosion disasters were delineated, and the primary causal variables necessary for effective risk assessments and scientific investigations were derived.

A Case Study of Risk Assessments and Safety Measures in a PCB Manufacturing Process (인쇄회로기판 제조 공정에서 위험성평가와 안전조치 적용 사례 연구)

  • Lee, Young Man;Lee, Inseok
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.120-128
    • /
    • 2022
  • Printed circuit boards (PCBs) are a basic component in the electronics industry and are widely used in nearly all electronic products, such as mobile phones, tablet computers, and digital cameras, as well as in electric equipment. PCB manufacturing involves the use of many chemicals and chemical processes and therefore has more risks than other manufacturing sectors. This study aims to identify the causes of possible accidents during PCB manufacturing through risk assessment, develop and implement safety measures, and evaluate the effectiveness of these measures. Note that the safety measures developed to mitigate the risks of a certain process were also implemented for other similar processes. The risk assessments conducted over seven years, from 2015 to 2021, at a PCB manufacturing company identified 361 hazardous processes. Between 2016 and 2019, 41-56 hazardous processes were identified per year; such processes decreased to fewer than 20 per year after 2020. Application of the risk assessment results to the improvement of the hazardous processes with the similar characteristics seems to be effective in decreasing the risks. Equipment-related factors such as lack of appropriate maintenance, low work standards, and defective protection devices were responsible for 59.8% of all possible accidents. Because PCB manufacturing involves many chemicals, skin contact with hazardous substances, electric shock, fire, and explosion were the most common types of possible accidents (81.7%). In total, 505 safety measures were implemented, including 157 related to purchase and improvement of equipment and devices for safety (31.1%), 147 related to the installation/modification of fire prevention facilities (29.1%), and 69 related to the use of standard electrical appliances (13.7%). Risk assessment conducted after implementing the safety measures showed that these measures significantly decreased risk; 247 processes (68.4%) had a risk level of 3, corresponding to "very low," and 114 processes (31.6%) showed a risk level of 4, corresponding to "low." In particular, risk assessment of 104 processes with risk scores of 12 and 10 other processes with risk score of 16 showed that the risk decreased to 4 after implementing the safety measures. Thus, implementing these measures in similar manufacturing sectors that involve chemical processes can mitigate risk.

A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique (4M 기법을 활용한 전기화재 예방대책 수립 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

Mechanism analysis through Water fire case (정수기 화재발생 사례를 통한 재현실험)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.593-618
    • /
    • 2011
  • Development of the economy and the growing income of people interested in the leisure and health has been focused. Past the town common wells and groundwater around the water, but health is a priority these days to solve the drinking water directly from tap water, but most people work from home, through the water purifier has been resolved. Depending on seasonal changes and personal taste of coffee, if you can enjoy a snack and water purifier is a restaurant, lounge, public areas and focusing on the rapid spread of the fire, water purifier as compared to the total number of fires increased by 0.03% per year trend on, but the washrooms fire and fire-related research data and case studies with analysis of the exact cause lack of proper preventive measures are insufficient reality. In this study, focusing on electrical energy using a water cooler to understand the structure and principles of fire, the fire revealed the mechanism is vulnerable to the consideration of factors, the exact cause of the fire investigation and the Assistant, manufacturing defects, and to contribute to fire prevention review should.

  • PDF

Evacuation Safety Evaluation of Tourist Hotels with the Fire Alarm Method

  • Moon, Sung-Chun;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.363-375
    • /
    • 2021
  • The purpose of this study is to analyze the safety of evacuation using the Pathfinder program for the alert at once, the priority alarm method, the priority alarm method for the four floors above, and the sequential priority alarm method, which is a modification of the priority alarm method specified in the tourist hotel building. Currently, in Korea's National Fire Safety Codes (NFSC), fire alarm methods are compulsorily applied differently depending on the number of floors and total floor area of a building. Although the growth rate is getting faster due to the diversification of building structures, it is still an obstacle to improving evacuation safety to comply with the standardized fire alarm method in NFSC. As a result of the experiment, the evacuation time was found to be faster with the priority alarm method for the four floors above than the priority alarm method applied to the specific firefighting object. Compared to the priority alarm method applied to the tourist hotel, which is a specific firefighting target with 5 or more floors and a total floor area of more than 3,000m2, the time was shortened by 3.7 seconds when measured by applying the priority alarm method for the four floors directly above. This indicates that it is necessary to take measures to select a fire alarm method suitable for the structure and environmental conditions of the building rather than applying the uniform NFSC regulations.

Fire Safety Measures for the Key Cultural Assets in Korea through Case Analysis (화재사례분석을 통한 문화재 화재안전 대책)

  • Park, Daewoo
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.1
    • /
    • pp.64-74
    • /
    • 2011
  • Cultural properties should be protected more than other facility because of its symbolization of a nation's historic and conservative value. So proper and effective actions for the management of our legacies is necessary. On this study, we'll research cases of cultural properties fires and manage to show the safety system of legacy and analyze problems of the system so that we can result in improvements for the safety of our treasures. This study is not to include almost all kind of cultural assets but only confined in a category of wooden materials, so there's limit of this study. And we should consider fires of tangible cultural properties, souvenirs and folk materials later period.

노말프로판올의 자연발화온도와 발화지연시간의 관계

  • 하동명;최용찬;한종근;김한돌;신용범;정세훈;이문선;윤준혁;류정열
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.154-159
    • /
    • 2003
  • 화학공장과 제조업 등의 사업장에서 발생하는 화재 및 폭발은 설비와 건물의 파괴뿐만 아니라 사업장의 근로자와 인근 주민에 대한 인명 피해까지 초래하는 경우가 많으므로 공정 안전을 위해 화재 및 폭발 분야의 연구에 많은 관심을 가져야 한다. 방화(Fire Protection) 및 방폭(Fire Protection)에 관련되는 특성치로 MSDS의 5번째 항목인 폭발화재시대처방법(Fire-fighting Measures)에서는 폭발(연소)한계(Explosive Limit 혹은 Flammability Limit), 인화점(Flash Point), 최소발화온도(AIT: Auto-ignition Temperature)가 제시되고 있다.(중략)

  • PDF

Cause of Explosion of the Indoor Shooting Range Fire in Busan and Safety Measures (부산 실내사격장 화재의 폭발원인과 안전대책)

  • Park, Woe-Chul
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.68-72
    • /
    • 2010
  • 부산 실내사격장 화재의 사격실 내 폭발의 원인을 추정하고 안전대책을 강구하기 위해 화재 시뮬레이션과 외국 실내사격장 화재의 사례조사를 수행하였다. 사격실 내의 폭발원인은 다공성 계란판형 폴리우레탄 흡음재와 흡음재에 축적된 잔류화약 분말의 격렬한 연소로 추정되었다. 실내사격장의 안전대책으로 폴리우레탄 흡음재의 사용금지, 잔류화약의 제거와 철저한 관리, 금연, 탄자받이 주위의 강재 요소 제거, 효율적 환기 등이 요구된다.

  • PDF