Vulnerability Analysis on Fire Service Zone using Map Overlay Method in GIS (GIS 기반 중첩기법을 이용한 소방서비스 취약지역 분석)

  • Lee, Seul-Ji;Lee, Ji-Yeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.91-100
    • /
    • 2011
  • Fire stations should be located in optimal location to act quickly in case of emergency and minimize damages as a public facility that protects life and property of local residents. Siting fire stations without regard for the accessibility and occurrence factors of an accident may provide fire service unequally. Therefore service analysis is necessary to reduce the blind spot of disaster and safety and to offer equal fire-service at this time. Especially fire stations can service more efficiently than before by reducing a more likely vulnerable area. This study suggests methods of mapping index of value that represents vulnerability of the occurrence of an accident and extracting service zone map of fire stations, as an initial research for offering efficient fire service. Geographical distribution mismatch between service zone map and vulnerability map is figured out and vulnerable area for fire service is defined by using map overlay method.

Activation Conditions of Sprinkler Head Considering Fire Growth Scenario (화재성장시나리오에 따른 스프링클러 헤드의 작동조건)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.45-51
    • /
    • 2020
  • The aim of this study is to investigate the gas temperature and velocity during sprinkler activation considering the fire growth scenario based on the thermal response model of the sprinkler. The fire source is assumed to have time square fire growth scenarios with a maximum heat release rate of 3 MW. Eight types of standard and fast-response sprinkler heads with an operating temperature range of 65-105 ℃ and a response time index range of 25-171 m1/2s1/2 were adopted. The temperature difference between the gas stream and the sensing element of the sprinkler head decreased as the fire growth slowed down, and the RTI value decreased. The overall gas temperature and velocity conditions predicted using the FDS model at sprinkler activation were in reasonable agreement with those of standard test conditions of the sprinkler head response. However, the sprinkler head could be activated at lower limits of gas temperature and velocity under the current test conditions for a slowly growing fire scenario.

Risk Assessment of Smoke Generated During Combustion for Some Wood (일부 목재의 연소 시 발생되는 연기의 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.33 no.4
    • /
    • pp.373-380
    • /
    • 2022
  • In this study, Chung's equations 1, 2, and 3 were extended to standardize smoke safety rating evaluation in case of fire, and Chung's equations-V, smoke performance index-V, and smoke growth index-V were calculated. Five types of wood were selected and their smoke indices were measured using the cone calorimeter method according to ISO 5660-1. The smoke risk was graded by the smoke risk index-VI according to Chung's equation-VI. Smoke risk index-VI increased in the order of PMMA (1) ≈ maple (1.01) < ash (1.57) < needle fir (4.98) < paulownia (46.15) < western red cedar (106.26). It was predicted that maple and ash had the lowest smoke risk, and paulownia and western red cedar had the highest. The five samples' CO mean production rate (COPmean) was 0.0009~0.0024 g/s, indicating that these woods were incompletely burned than the polymethyl methacrylate (PMMA) reference material. Regarding the smoke properties of the chosen woods, the smoke performance index-V (SPI-V) increased as the bulk density increased, and the smoke risk index-VI (SRI-VI) decreased.

Experimental Study on the Toxicity Characteristics of Non-Class 1E Cables according to Accelerated Deterioration (가속열화에 따른 비안전등급 케이블의 독성특성에 관한 실험적 연구)

  • Jang, Eun-Hui;Kim, Min-Ho;Lee, Min Chul;Lee, Sang-Kyu;Moon, Young-Seob
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.105-113
    • /
    • 2019
  • This study investigates the toxicity characteristics of two Non-Class 1E Cables (For security reasons, we refer to company A and company B) used in nuclear power plants according to the accelerated deterioration period. In accordance with NES 713 test equipment and standards, tests were carried out on non-aged cables and the cables subjected to 20- and 40-year-accelerated-deterioration; each of the cables was further classified into sheath and insulation. The test results showed that the toxicity indices of 20- and 40-year-accelerated-aged cables were higher than those for the non-aged cables, and 20-year-aged cables of both A and B companies showed the highest toxicity indices. This is attributed to the extensive emissions of carbon monoxide and halide gases such as hydrogen chloride and hydrogen bromide. Furthermore, to analyze the toxicity indices of sheath and insulation in detail, the US Department of Defense standard (MIL-DTL) was applied to determine whether the Toxicity index (T.I.) allowance was exceeded, and the results showed that the insulating materials emitted considerably more than the allowable limit.

A Study on the Planning Direction for Social Communication in a High-density Residential Environment (고밀 주거환경에서의 사회적 소통을 위한 계획 방향 연구)

  • Lee, Jae-Young;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • The purpose of this study is to present the direction of the plan to transform the residential complex into a space that can provide an open residential environment that can lead to social communication and exchange without being closed to the urban residential environment, especially in the apartment complex environment, which is becoming more dense. As a result of the Openness analysis of the 'Codan Shinonome Canal Court', the overall accessibility was good in terms of space utilization, and the openness was low in terms of the spatial composition, which is a physical environment due to the dense block type. When looking at the overall openness of the Codan Sinonome complex in terms of analysis by block, the corrected openness index (C.O.I) for all six blocks was 0.245, the corrected accessibility index (C.A.I) was 1.447 and the openness composite index (O.C.I) was assessed at 1.692. This was due to the formation of high-density block-type urban dwellings and the introduction of S-shaped streets and the layout of low-rise urban support facilities and commercial facilities. The Codan Sinonome Canal Court, which is considered an "open city residence," quantitatively confirmed that it embodies macro-space structure and human-scale space environment even in high-precision environments.

Rejection Degree by Fuzzy Significance Probability

  • Choi, Gyu-Tag;Park, Il-Soo;Nam, Hyun-Woo;Moon, Jong-Choon
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.135-139
    • /
    • 2014
  • We propose some properties for fuzzy hypothesis test by fuzzy significance probability. First, we define fuzzy number data and fuzzy significance probability for repeatedly observed data with alternated error term. By the agreement index, we compare fuzzy significance probability with significance level and drawing conclusions the degree of acceptance and rejection by agreement index.

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

New Smoke Risk Assessment on Wood Treated with Silicone Compound (실리콘 화합물로 처리된 목재의 새로운 연기위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.16-27
    • /
    • 2019
  • A burning test was conducted on the smoke and combustion gases generated from cypress wood treated with sodium silicate, 3-aminopropyltrimethoxysilane sol, 3-(2-aminoethylamino)propylmethyldimethoxysilane sol, and 3-(2-aminoethylamino) propyltrimethoxysilane sol. The silicone compound sol was applied to each of the cypress wood specimens three times with a brush. The smoke and combustion generation gas were analyzed using a cone calorimeter (ISO 5660-1) and the smoke was also evaluated by applying new smoke risk assessment method. The smoke performance index (SPI) of the cypress treated with silicone compound increased 1.66 to 8.42 times and the smoke growth index (SGI) was 11.8 to 88.2%, respectively. The smoke intensity (SI) is expected to be 1.0~50.5% lower than that of the base specimens, resulting in lower smoke and fire hazards. The third maximum carbon monoxide (COpeak) concentration of the specimens treated with silicone compounds was 22.5~33.3% lower than that of the base specimens. On the other hand, it produced potentially fatal toxicity that was 1.48~1.72 times higher than the US Occupational Safety and Health Administration (OSHA) acceptance standard (PEL). Cypress wood itself produced a high carbon monoxide concentration, but the silicon compound played a role in reducing this level.

Postfire reliability analysis of axial load bearing capacity of CFRP retrofitted concrete columns

  • Cai, Bin;Hao, Liyan;Fu, Feng
    • Advances in concrete construction
    • /
    • v.10 no.4
    • /
    • pp.289-299
    • /
    • 2020
  • A reliability analysis of the axial compressive load bearing capacity of postfire reinforced concrete (RC) columns strengthened with carbon fiber reinforced polymer (CFRP) sheets was presented. A 3D finite element (FE) model was built for heat transfer analysis using software ABAQUS. Based on the temperature distribution obtained from the FE analysis, the residual axial compressive load bearing capacity of RC columns was worked out using the section method. Formulas for calculating the residual axial compressive load bearing capacity of the columns after fire exposure and the axial compressive load bearing capacity of postfire columns retrofitted with CFRP sheets were developed. Then the Monte Carlo method was used to analyze the reliability of the axial compressive load bearing capacity of the RC columns retrofitted with CFRP sheets using a code developed in MATLAB. The effects of fire exposure time, load ratio, number of CFRP layers, concrete cover thickness, and longitudinal reinforcement ratio on the reliability of the axial compressive load bearing capacity of the columns after fire were investigated. The results show that within 60 minutes of fire exposure time, the reliability index of the RC columns after retrofitting with two layers of CFRPs can meet the requirements of Chinese code GB 50068 (GB 2001) for safety level II. This method is effective and accurate for the reliability analysis of the axial load bearing capacity of postfire reinforced concrete columns retrofitted with CFRP.

Research on Risk Assessment of Lithium-ion Battery Manufacturing Process Considering Cell Materials (셀소재를 고려한 리튬2차전지 제조공정 위험성 평가 방법 연구)

  • Kim, Taehoon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.76-87
    • /
    • 2022
  • Lithium-ion batteries (LIBs) have attracted much interest for their high energy density (>150 mAh/g), high capacity, low self-discharge rate, and high coulombic efficiency. However, with the successful commercialization of LIBs, fire and explosion incidents are likely to increase. The thermal runaway is known as the major factor in battery-related accidents that can lead to a series of critical conditions. Considering this, recent studies have shown an increased interest in countering the safety issues associated with LIBs. Although safety standards for LIB use have recently been formulated, little attention has been paid to the safety around the manufacturing process for battery products. The present study introduces a risk assessment method suitable for assessing the safety of the LIB-manufacturing process. In the assessment method, a compensation parameter (Z-factor) is employed to correctly evaluate the process's safety on the basis of the type of material (e.g., metal anode, liquid electrolyte, solid-state electrolytes) utilized in a cell. The proposed method has been applied to an 18650 cell-manufacturing process, and three sub-processes have been identified as possibly vulnerable parts (risk index: >4). This study offers some crucial insights into the establishment of safety standards for battery-manufacturing processes.