• 제목/요약/키워드: Fire Road

검색결과 202건 처리시간 0.026초

터널운영시스템 표준화 연구 (A Study on the Standardization of Operation System for Road Tunnels)

  • 김태형;김진;금재성;태재호;김선홍;홍대희
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.75-79
    • /
    • 2008
  • Since tunnel construction order was placed one by one, various sensors and actuators installed at the RTU and higher level system in each tunnel maintenance office had their own protocols depending on construction company. The TGMS testbed established on the extended region of Yong-dong Highway, for example, did not have consistent protocol between each automation levels and management levels without considering the functions and/or roles of each level. The management sever in each tunnel was simply networked to the TGMS server. Therefore, it is impossible to implement a new control algorithm as well as to integrate each other since each tunnel was constructed by different company. So, if the construction company is out of business, there is no way to maintain the corresponding tunnel effectively. In order to solve this problem, all the necessary standard protocols was established between automation level and management levels. These interface standards provide the clear classification between individual tunnel system and tunnel management system. So, even if construction company is different, its effect is minimized, so that it is expected to successfully establish PC based TGMS.

  • PDF

국내·외 구급차 규정, 디자인 및 개선에 관한 조사연구 (An Investigation of the Regulation, Design and Improvement of Domestic and International Ambulances)

  • 신동민;김승용;한용택
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.172-179
    • /
    • 2014
  • This research suggests that the regulation, design and improvement of domestic and international ambulances so that make the basis for the future ambulance in Korea. It is true that the diversification of current disasters, increasing elderly population, the increase in emergency patients, due to the lack of effective transfer system, emergency vehicle's performance problem, and the aging of ambulances cause have difficulty in providing effective emergency services in domestic country. Therefore, in order to improve the effectiveness of ambulance, the history of ambulance, other relevant provisions include international, design and directions to be improved were investigated, and also research directions of the ambulance are suggested in domestic country. In this research, suggests the following conclusions to improve domestic ambulance 1. Through standardization of the spacing and location of an ambulance is needed to maximize the treatment room. 2. The interior of the ambulance design for hygiene and infection control should be included. 3. Stretcher and equipment are designed to be fitted to each other should be standardized. 4. Especially during transfer maintain the road, noise, vibration, and shock-absorbing function to emphasize the importance. 5. The improvement of ergonomic design is necessary for the possibility of applying to many people.

다중 분산부하 전압강하산정 프로그램 연구 (A Study of the Voltage drops computation program on multi-distributed random loads)

  • 강차녕;권세혁;조성필
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.37-42
    • /
    • 2006
  • 전선에서 전압강하는 열 손실을 의미한다. 이 열은 절연체의 특성을 변화시켜 절연성능을 저하시키게 되고 나아가 누전, 감전, 정전 및 화재 등의 사고를 일으키는 원인이 되기도 한다. 그러므로 전압강하에 대한 최적화 설계는 전기설비의 안전성과 경제성을 보장하는 중요한 요소가 되고 있다. 이에 저압의 전기설비인 가로등, 빌딩, 지하철역사 등 공공의 안전확보가 요구되는 다중 분산부하계통에서의 전압강하가 전기배선에 미치는 영향을 분석하고, 안전성 및 경제성 확보를 위한 전압강하산정 프로그램 및 최적화 방안을 연구 제시하고자 한다.

  • PDF

수소스테이션용 $20Nm^3/hr$급 수소제조장치 스케일-업 및 성능시험 (Performance test of scale-up $20Nm^3/hr$ scale hydrogen generator for hydrogen station)

  • 오영삼;백영순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.37-42
    • /
    • 2006
  • In this study, $20Nm^3/hr$ scale compact hydrogen generator which can be apply to the hydrogen station was tested for hydrogen station application. $20Nm^3/hr$ scale compact hydrogen generator was developed by upgrading concept of stacking plate reactor from former $20Nm^3/hr$ scale plate hydrogen generator. concepts for improving system efficiency and performance include such as idea of heat recovery from the exhaust, exhaust duct which is especially design for plate type reactor reinforcement of insulation, enlargement of heat exchange area of reactor, introduction of desulphurizer reactor and PROX rector in a compact design, introduction of back fire protection structure of plate burner and so on, We can learn that final prototype of scale-up $20Nm^3/hr$ scale compact hydrogen generator can be operated steadily in 100% road at which over 94% of methane conversion(S/C=3.75) was obtained. In case of making up the weak point, we expect that it is possible to apply to hydrogen station by way of showing an example.

  • PDF

GIS를 활용한 119 구조구급서비스의 도착지체 및 출동배치에 대한 공간분석 - 경상북도 사례 연구 - (A Spatial Analysis about Arrival Delay and Dispatch Distribution of the 119 Rescue-Aid Service utilizing GIS - Gyeongsangbuk-Do Case Study -)

  • 오창석;이승원;이인묵;고승영
    • 대한토목학회논문집
    • /
    • 제32권1D호
    • /
    • pp.13-22
    • /
    • 2012
  • 국가가 운영하는 119 구조 구급 출동서비스는 응급상황에서 인간의 생명과 직결되는 매우 중요한 사회적 응급 운송시스템이며, 고령화 사회로의 급속한 전이를 보이는 우리나라의 현 사회구조를 비추어 볼 때 그 중요성은 더욱 커져가고 있다. 특히 긴급차량의 사고현장 도착시간은 환자의 초등 조치에 영향을 미치는 중요한 변수이며, 출동서비스 센터의 위치, 사고 현장까지의 접근성 등 도로네트워크 속성에 따라 영향을 받을 수 있다. 따라서 본 연구에서는 경상북도의 구조 구급활동자료를 바탕으로 119 긴급차량의 도착지체 및 출동배치의 효율성을 분석하고자 하였다. 먼저 구조 구급서비스의 출동분포 특성을 살피고, 구조 구급서비스 시설, 도로 네트워크의 위치정보가 주어진 상태에서 GIS의 공간분석을 활용하여 구조 구급서비스 시설의 일정 반경에 포함되지 않는 사고다발지역(사각지역)과 국가교통 DB상의 도로네트워크 입력속도, 실제 구조 구급일지 상의 현장 도착시간을 각각 입력 값으로 하는 긴급차량 도착지체 지역을 GIS 맵으로 표출하였다. 또한 출동거리가 10km 넘는 원거리 출동빈도가 높은 구조구급 서비스시설의 출동배치 효율성을 분석하고, GIS의 OD 네트워크 분석을 이용하여 도로네트워크상 최단거리에 위치한 서비스시설에서 출동이 이루어지도록 구조 구급서비스망을 개선하였다.

Fingerprint of Carcinogenic Semi-Volatile Organic Compounds (SVOCs) during Bonfire Night

  • Pongpiachan, Siwatt
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권5호
    • /
    • pp.3243-3254
    • /
    • 2013
  • It is well known that increased incidences of lung, skin, and bladder cancers are associated with occupational exposure to PAHs. Animal studies show that certain PAHs also can affect the hematopoietic and immune systems and can produce reproductive, neurologic, and developmental effects. As a consequence, several studies have been attempted to investigate the fate of PAHs in atmospheric environment during the past decades. However, there is still a lack of information in regard to the atmospheric concentration of PAHs during the "Bon Fire Night". In this study, twenty-three polycyclic aromatic hydrocarbons and twenty-eight aliphatics were identified and quantified in the $PM_{10}$ and vapour range in Birmingham ($27^{th}$ November 2001-$19^{th}$ January 2004). The measured concentrations of total particulate and vapour (P+V) PAHs were consistently higher at the BROS in both winter and summer. Arithmetic mean total (P+V) PAH concentrations were $51.04{\pm}47.62$ ng $m^{-3}$ and $22.30{\pm}19.18$ ng $m^{-3}$ at the Bristol Road Observatory Site (BROS) and Elms Road Observatory Site (EROS) respectively. In addition arithmetic mean total (P+V) B[a]P concentrations at the BROS were $0.47{\pm}0.39$ ng $m^{-3}$ which exceeded the EPAQS air quality standard of 0.25 ng $m^{-3}$. On the other hand, the arithmetic mean total (P+V) aliphatics were $81.80{\pm}69.58$ ng $m^{-3}$ and $48.00{\pm}35.38$ ng $m^{-3}$ at the BROS and EROS in that order. The lowest average of CPI and $C_{max}$ measured at the BROS supports the idea of traffic emissions being a principle source of SVOCs in an urban atmosphere. The annual trend of PAHs was investigated by using an independent t-test and oneway independent ANOVA analysis. Generally, there is no evidence of a significant decline of heavier MW PAHs from the two data sets, with only Ac, Fl, Ph, An, 2-MePh, 1+9-MePh, Fluo and B[b+j+k]F showing a statistically significant decline (p<0.05). A further attempt for statistical analysis had been conducted by dividing the data set into three groups (i.e. 2000, 2001-2002 and 2003-2004). For lighter MW compounds a significant level of decline was observed by using one-way independent ANOVA analysis. Since the annual mean of $O_3$ measured in Birmingham City Centre from 2001 to 2004 increased significantly (p<0.05), it may be possible to attribute the annul reduction of more volatile PAHs to the enhanced level of annual average $O_3$. By contrast, the heavier MW PAHs measured at the BROS did not show any significant annual reduction, implying the difficulties of 5- and 6-ring PAHs to be subject to photochemical decomposition. The deviation of SVOCs profile measured at the EROS was visually confirmed during the "Bonfire Night" festival closest to the $6^{th}$ November 2003. In this study, the atmospheric PAH concentrations were generally elevated on this day with concentrations of Fl, Ac, B[a]A, B[b+j+k]F, Ind and B[g,h,i]P being particularly high.

진주시 교통사고의 도시공간분포패턴 분석 (Pattern Analysis for Urban Spatial Distribution of Traffic Accidents in Jinju)

  • 성병준;유환희
    • 대한공간정보학회지
    • /
    • 제22권3호
    • /
    • pp.99-105
    • /
    • 2014
  • 교통사고는 화재와 더불어 도시지역에서 발생하는 인위적 재해 중 가장 높은 비중을 차지하고 있어서 보다 과학적인 원인분석과 더불어 다양한 예방대책수립이 필요하다. 본 연구에서는 지방중소도시인 진주시를 대상으로 2013년 발생한 교통사고 데이터를 교통사고 발생 원인별 분석, 발생 시간 및 계절적 특성분석 등 위치정보와 연계하여 시공간적 분포특성을 분석하고 토지이용계획에 따른 도시공간개발 특성과 연계함으로서 교통사고와의 공간적 상관성을 분석하였다. 그 결과 사고유형별 사고 분포특성을 보면 측면직각추돌(차 대 차), 횡단중사고(차 대 사람)가 밀도분석과 최근린분석에서 가장 군집도가 높았으며, 중심상업지역과 고밀도 주거지역, 공업지역을 연결하는 도로상에서 가장 많이 발생하는 특성을 보였다. 또한 피해상황에서는 인적피해가, 기상상태에서는 맑은 날이, 노면상태는 건조할 때가, 도로형태는 삼지교차로 일 때가 가장 높은 군집도를 보여주었다.

도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구 (An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel)

  • 이동호;김하영;윤찬훈;김진
    • 한국터널지하공간학회 논문집
    • /
    • 제12권3호
    • /
    • pp.215-222
    • /
    • 2010
  • 본 연구에서는 도로터널 화재 시 지하 및 지상 환기소의 방재 효율을 검토하기 위해 터널 축소모형실험을 실시하였다. 터널 모형은 Froude 상사를 기본으로 도로터널을 1/50로 축소하여 20 m의 모형 터널을 제작하였다. 방재 효율 분석에 적용된 연직갱은 설제 터널 설계시 고려된 두 가지 모형으로서 실터널 560, $280\;m^3/s$의 배연량을 1/50으로 상사하여 적용하였다. 결과로 모두 연직갱을 통한 CO 가스의 전량 배출이 가능한 것으로 분석되었다. 두 환기소의 CO 농도는 지상 환기소가 지하 환기소 보다 2.23~2.73 ppm 작게 배출되었다. 그리고 지상 환기소의 경우 터널 벽면의 냉각효과로 인해 화재 후 온도의 상승이 지하 환기소보다 $0.53{\sim}0.94^{\circ}C$ 낮게 나타났다. 이상의 축소모형 환기소 내 CO농도 및 온도변화의 분석 결과, 방재적인 측면에서 볼 때 도로터널 내 환기소의 위치는 지하보다 지상에 위치하는 것이 유리할 것으로 판단되었다.

수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석 (Numerical analysis on effect of hole size on Emergency Evacuation Support System)

  • 김지태;박원희;이덕희;노경철
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.324-329
    • /
    • 2020
  • 비상피난 지원시스템은 화재 발생시 차연막이 형성되고 차연막 내부로 외기를 급기 가압을 해주어 연기의 유입을 막아주어 안전한 대피로를 제공한다. 본 연구에서는 수치해석을 통해 급기구 지름이 10, 15, 20, 30 mm로 변화 할 때 비상피난 지원시스템 차연막 내부에 급기구 크기가 유동에 미치는 영향을 분석하였다. 그 결과 급기구 지름이 감소할수록 비상피난지원 시스템 입구부터 출구 길이 방향으로 급기구를 통한 유량이 비교적 고르게 형성 되는 양상을 보였다. 또한 20 mm 이상으로 급기구를 타공 할 경우 출구부 근처에는 급기 유량이 거의 발생하지 않는 문제점이 발생 하므로 급기구 지름을 20 mm 보다 작게 타공 해야 할 것으로 판단된다. 차연막 내부 공간 압력은 20 mm 이하로 타공시 길이 방향으로 비교적 매우 균일한 분포를 보였다. 또한 수치해석 결과를 이용하여 급기구의 부차 손실계수을 산출 하였으며 약 K=1.5 으로 계산되었다. 따라서 향후 비상피난 지원 시스템 설계시 본 연구에서 도출한 급기구 지름에 따른 유동특성과 급기구의 부차손실을 적용하여 적절한 설계가 수행될 수 있을 것으로 판단된다.

리빙 씨어터: 탄생과 소멸에 관한 사적(史的) 연구 (The Living Theatre: A History Study of Its Birth and Death)

  • 김중효
    • 한국연극학
    • /
    • 제40호
    • /
    • pp.207-237
    • /
    • 2010
  • Concentrating on the birth, life, and death of the Living Theatre, almost half a century avant-garde group, the primary purpose of this study at large is to explore its counter-cultural philosophy. While taking a chronological form adapting the biological order, the paper focuses on the troupe's productions: , , , , and . Through out these productions the philosophy of the Living Theatre seemed to included communal, anti-intellectual, politically radical, generally Utopian, and proselytizers for sexual freedom. The history of the Living Theatre interestingly parallels the history of the Beck's theatre in occupation and shut down. The first New York theatre was closed by fire inspectors for instance. The second theatre was declared unsafe, and locked up by the Building Department. The third theatre was seized by the IRS, consequently shut down. In 1984, after more than 25years from the third building, the Living Theatre settled once again on East Third Street in Manhattan. The theatre was however evacuated by the New York City Fire Department in 1993 and once more took to the road. With these struggles, the Becks' profound aspiration of the counter-cultural insurgency came to harden as strong as 'iron' in some ways. With the outstanding components of counter-cultural philosophy and style, the Living Theatre, in the course of the transformation, absorbed and then reflected virtually every phase for the Living Theatre were vehicles for more than just aesthetics. The group seemed to propagandize its beliefs rather performing productions. Accordingly, both on and off-stage action of the Living Theatre caused great controversy either through political activism of individual members or through the unconventional collective life style. No avant-garde theatre company was more emblematic of the rebellious spirit of the sixties than the Living Theatre. Like the first great transformation, the Becks' encounter, their personal values and the form of theatre they created had blended 'so inextricably that the vitality of each was dependent on the other.' The Becks always urged unity and harmony at all levels of human life, but not at any price. The anticapitalist ideal inspired the Becks to promote a politically motivated campaign throughout their productions. They believed the revolution is desirable but in the state of non-violence and the expansion of human consciousness. Julian Beck's gravestone identifies his as pet, painter, actor, and anarchist. The Living Theatre was a 'small umbrella' under which the Becks and its members could breath and unfold their dream on stage or in the street.