• 제목/요약/키워드: Fire Road

검색결과 202건 처리시간 0.022초

횡류식 대배기구 방식을 적용한 도로터널에서 화재시 최적배연풍량 선정에 관한 연구 (A Study of Smoke Exhaust Rate for the Transverse Ventilation with Oversized Exhaust Ports in Road Tunnel)

  • 유지오;윤성욱;이동호
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.7-12
    • /
    • 2006
  • Recently, the application of transverse ventilation system with oversized exhaust ports has been increased in bidirectional road tunnel in order to improve smoke exhaust ability. Therefore, in this study, for decision of the optimal smoke exhaust rates in the transverse ventilation system, several standards of nations are compared and numerical simulations with variations of exhaust flow rates are carried out in terms of smoke spread distance by FDS ver. 3.1. As results, in the case of no internal longitudinal air velocity in tunnel, the smoke exhaust rate of $80m^{3}/s$ (the smoke generation rate at HRR of 20MW) is sufficient enough to limit the smoke spread within 250m in 6 minutes after the fire. However, in the case of the internal longitudinal air velocity at 2.5m/s, the smoke exhaust rate should be increased $130m^{3}/s$.

중규모터널 방재용 제트팬 초기 가동시간에 관한 연구 (A Study on Jet Fan Start Time in Medium-Length Tunnel Fires)

  • 김두영;이창우
    • 터널과지하공간
    • /
    • 제20권6호
    • /
    • pp.465-474
    • /
    • 2010
  • 중규모 터널(연장 1 km 이내) 건설은 최근 매년 30% 이상의 증가율을 보이고 있으나 환기 및 방재시설 설치기준은 제정되어 있지 않은 상태라 장대터널을 대상으로 한 설치기준을 따르고 있다. 이에 따라 중규모터널 환기 및 방재시설의 최적화 노력이 요구되고 있다. 본 연구에서는 중규모 터널 내 20 MW 규모의 화재 시 발생하는 화재연 역류거리, 고온 열기류 확산범위, 가시거리 20 m 이하(상류) 구간분포, 임계풍속 확보여부, 대피시간 등을 CFD 분석을 통해 방재팬의 적정 초기 가동시간을 도출하여 방재시스템의 최적운전 방안의 제시를 목적으로 한다.

내화패널이 부착된 프리캐스트 PSC 풍도슬래브의 정적/동적하중에 관한 실험연구 (Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads)

  • 김태균;배정;최헌;민인기
    • 대한토목학회논문집
    • /
    • 제32권4A호
    • /
    • pp.245-253
    • /
    • 2012
  • 본 연구에서는 장대터널이나 지하차도 등에 시공되는 횡류식 환기시스템을 구성하는 내화패널이 부착된 프리캐스트 풍도슬래브의 구조성능을 평가하기 위해서 실물모형 구조실험을 수행하였다. 또한, 내화패널의 휨강도와 Pull-off test를 통하여 내화패널과 슬래브의 부착성능 등의 기초성능을 우선적으로 확인하였다. 실물모형시험은 내화패널과 프리캐스트 PSC 슬래브의 정적 휨성능과 차량의 통행 시 발생하는 표면압력 이상의 하중에 대한 동적피로부착성능을 평가하였다. 동적피로하중 시험에서 내화패널과 PSC 슬래브 사이의 탈락이나 손상은 발생하지 않았으며, 정적재하시험에서도 매우 안정적인 거동을 보였으며, 하부에 부착된 내화패널의 탈락은 발생하지 않았다. 따라서 시공 중이나 시공 후 외부하중에 의해 내화패널의 탈락은 발생하지 않을 것으로 판단된다.

도로터널 화재 시의 행위자 기반 대피 시뮬레이션 (Agent-Based Evacuation Simulations of Road Tunnels in the Event of a Fire)

  • 김병일;김창윤;김두연
    • 대한토목학회논문집
    • /
    • 제35권5호
    • /
    • pp.1157-1163
    • /
    • 2015
  • 최근 들어 도로의 선형 개량 및 설계속도 향상으로 인해 장대터널에 대한 수요가 증가함에 따라 대피 시간의 지연과 같은 이용자 취약성이 더욱 높아지고 있다. 향후 도로터널의 장대화 경향은 심화될 전망이므로 화재에 대한 이용자 취약성을 검토하고 효율적 대피 방안을 세우지 못한다면 더 큰 인명 피해가 발생할 수 있을 것이다. 이에 본 연구는 적정시간 안에 이용자들이 대피해야 사상자 발생이 최소화 될 수 있다는 점을 고려해 다양한 상황 조건 아래 대피 시간을 산정하는 연구를 수행하였다. 개발된 모형에서 행위자는 이용자이며, 이들은 퇴피성, 직진성, 좌향성 등의 행위 규칙에 따라 대피를 진행하도록 모형을 설계하였다. 개발된 모형은 ODD 규약에 따라 설명하였고 시뮬레이션을 위해 NetLogo 5.2를 활용해 구현하였다. 이 모형과 두 가지 시나리오를 활용해 현행 피난연결통로 설치지침을 평가하였다. 그 결과 터널 내부의 차량이 정체 수준일 경우 현행 지침은 다소 미흡한 것으로 판명되었다.

포스트 - 묵시록 미래의 생존과 선의 실행: 코맥 매카시의 『로드』 (Survival and Goodness in a Post - apocalyptic Future: Cormac McCarthy's The Road)

  • 성정혜
    • 영미문화
    • /
    • 제16권2호
    • /
    • pp.71-88
    • /
    • 2016
  • Cormac McCarthy's The Road depicts a post-apocalyptic future in which the time and reason of catastrophe are not specified, but it can be seen to project the contemporary social and ethical concerns in the dismal setting. In this respect, the journey the man and boy depart for to the South is on one hand a journey to seek a warmer place to support their lives in the literal sense and, on the other hand, a journey to seek 'what a human being is' in the devastated world in a metaphorical sense since they face extremely harsh and tremendously poignant conditions in which their creed as human beings is tested. This paper aims to explore the hazards of the current society that the text criticizes and the morality and ethical values to be preserved and pursued. The second chapter examines how the text describes the contemporary crisis through the dark and coldness of the land and its sterility. The land produces almost nothing as the entire surface was scorched and is now covered with thick ashes. It shows perfectly a destroyed and irrecoverably frozen land. Throughout this desolate and ruined land, the atrocity and violence of the survivors goes beyond the limit. Ravaging strangers and plundering villages are widely spread. These conditions mirror the apparent selfishness and immorality of the recent society. The third chapter analyzes the man's inconsistent or dualistic narrative on the good. He knows what the good is but doesn't allow the boy to demonstrate the good behavior on others. His conflict is rooted in his hope to protect his son from being attacked by others. Therefore it can be interpreted that the meaning and orders of living in this post-apocalyptic period are uncertain and indecisive. The fourth chapter examines the belief the man and the boy clings to. Unlike the man's contradictory decisions, he shows definite firmness to be 'the good' by not eating people and carrying 'the fire.' Until he dies, the man endeavors to protect his son and have him acquire the moral conviction and strength to carry the fire in the world. In conclusion, the text reads the current society critically and highlights the importance of the humanity that must not be discarded throughout the generations.

터널에서 차량의 운행에 의해 생성되는 비정상 유동에 대한 실험적 연구 (Experimental study on vehicle-induced unsteady flow in tunnel)

  • 김정엽;신현준
    • 한국터널지하공간학회 논문집
    • /
    • 제11권4호
    • /
    • pp.411-417
    • /
    • 2009
  • 도로터널내 열유동장의 형성은 여러 가지 요인의 영향을 받는다. 즉 차량의 이동에 의한 피스톤 효과, 환기설비의 환기력, 자연풍 영향, 화재시 부력 등에 따라 도로터널내 기류가 형성된다. 차량의 이동에 의한 피스톤 효과는 도로터널내 기류생성의 일차적인 요인이며, 화재시 연기의 초기 거동에 영향을 줄 수 있다. 본 연구에서는 도로터널내 차량의 이동에 의해 생성되는 비정상 기류를 분석하기 위해서 단순한 형태의 터널과 차량에 대한 축소모형실험장치를 제작하고 실험을 수행하였다. 기본형, 전두부 사변형, 후두부 계단형의 3가지 형태로 차량의 형상을 변화시켜가며 차량운행에 따라 형성되는 터널내 압력과 기류속도를 측정하였다. 실험결과 터털내 생성되는 압력과 속도의 크기는 "기본형>후두부 계단형>전두부 사변형"의 순서로 증가하였다. 실험결과는 향후 3차원 수치해석 결과와의 비교, 검토를 통해서 수치해석 기술의 보완 및 신뢰성 확보를 위한 기초자료로 활용될 수 있다.

대공간용 비상피난지원 시스템에 화재가 미치는 영향 분석 (Influence of the Fire on Emergency Evacuation Support System)

  • 김지태;성건혁;박원희;이덕희;유우준;노경철
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.626-631
    • /
    • 2018
  • 비상 피난 지원 시스템은 화재시 차연막이 형성되며 차연막 내에 가압을 하여 안전한 피난로를 확보해주는 시스템이다. 안정적인 작동을 위해서는 비상 피난지원 시스템의 차연막은 적절한 내화성능을 갖추어야 한다. 따라서 본 연구에서는 화재가 차연막에 미치는 영향을 수치해석적 방법으로 분석하였다. 수치해석 대상은 다중이용 건축물의 대공간 의류 상점의 화재로 가정 하였으며 상점의 가연물에 따라 화재 시나리오를 설정하였다. 차연막의 내화 안전 온도는 화재에 의해 발생하는 고온의 가스 온도가 $200^{\circ}C$ 이하 일때로 가정 하였다. 그 결과 Ceiling jet 의 영향으로 천장 부분에서 가장 높은 온도가 나타났으며 차연막의 내화 안전성은 열 방출률에 따라 화재로부터 차연막의 거리가 20 m부터 또한 최대 열방출율시 30 m 이후에 확보 할 수 있을 것으로 판단하였다. 또한 비상 피난지원 시스템 내부로 연기 유입을 차단하기 위해 차연막 내부를 양압으로 유지 하여야 하며 약 5 Pa 이상 가압이 필요 할 것으로 판단하였다. 따라서 향후 비상 피난 지원 시스템의 설계시 본 연구의 결과가 유용하게 사용 될 수 있을 것으로 판단된다.

도로터널 화재시 반횡류식 균일배기 환기방식에서의 최적배연 연구 (A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation)

  • 전용한;유지오;김남진;서태범;김종윤
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.186-192
    • /
    • 2009
  • In this study it is intended to review the moving characteristics of smoke by performing visualization for calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for design of the smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, if it was assumed 0 critical velocity in the tunnel, the smoke exhaust air volume was limited within 250 meter in the road-tunnel disaster prevention indicator and the exhaust efficiency was from 55.1% to 95.8% in the result of this study. In case of oversized exhaust ports, the generated smoke is more than the case of uniform exhaust. When the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173\;m^3/s$, $236\;m^3/s$ for the distance of the moving smoke which can limit the distance to 250 m.

자동차 클러치, 수동변속기, 타이어 시스템의 마찰에 관련된 화재사례 연구 (Study for Examples of Fire Including Friction with Automotive Clutch, Manual Transmission and Tire System)

  • 이일권;문학훈;김진준
    • 한국가스학회지
    • /
    • 제19권3호
    • /
    • pp.49-53
    • /
    • 2015
  • 이 논문의 목적은 자동차 클러치, 수동변속기와 타이어 시스템의 마찰에 관련된 화재에 대한 고장사례를 분석하고 연구하는 것이다. 첫 번째 사례는 반복적으로 클러칭하면서 자동차의 클러치 디스크가 플라이 휠의 접촉면과 접촉하면서 열에 의해 과열되어 이 열이 수동변속기의 외부로 흘러 고착된 오일 찌꺼기에 옮겨 붙어 화재가 발생된 것으로 확인되었다. 두 번째, 사례로 변속 장치는 기어와 기어의 접촉에 의해 동력을 전달한다. 변속기 오일이 변속기 케이스의 균열로 인해 오일 부족 현상이 일어나 변속기 케이스 상단의 퇴적물에 의해 화재가 발생된 것을 확인하였다. 세번째 사례는 건조한 구덩이에서 빠져나오려고 반복적으로 가속페달을 작동시키면서 타이어와 도로의 마찰이 반복되면서 내부의 축적된 열에 의해서 화재가 발생된 것으로 확인되었다. 따라서, 운전자는 운전 중 마찰부에 화재가 발생하지 않도록 세심하게 관리하여야 한다.

고인성내화모르터(FR-ECC)를 사용한 장대터널 내화안전대책에 관한 연구 (A study on the fire resistance method using FR-ECC in long tunnel)

  • 김세종;김동준;권영진
    • 한국터널지하공간학회 논문집
    • /
    • 제13권1호
    • /
    • pp.9-18
    • /
    • 2011
  • 최근 이동거리와 물류수송의 급격한 증가로 인해 거리의 단축과 지형의 한계를 극복하기위해 장대터널의 수요가 급격히 증대되고 있으며 이에 따라 터널내화재사고에 대한 우려가 함께 증가하고 있다. 특히 터널 화재 온도는 일반 화재 온도와 달리 초기에 급격히 증가하는 현상을 보이고 있다. 하지만 국내에서는 이에 대한 대책마련이 미흡하고 실제시공한 사례가 없으므로 일본의 히다터널에 사용된 고인성 내화모르터의 사용과 국내에서 개발한 신기술의 현장적용을 통해 시공한 사례와 함께 그에 따른 앞으로의 터널구조물의 내화 및 내구성에 대한 방안을 제시해 보았다.