• Title/Summary/Keyword: Fire Road

Search Result 202, Processing Time 0.022 seconds

A Study on the Standardization of Operation System for Road Tunnels (터널운영시스템 표준화 연구)

  • Kim, Tae-Hyung;Kim, Jin;Keum, Jae-Sung;Tae, Jae-Ho;Kim, Sun-Hong;Hong, Dae-Hie
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.75-79
    • /
    • 2008
  • Since tunnel construction order was placed one by one, various sensors and actuators installed at the RTU and higher level system in each tunnel maintenance office had their own protocols depending on construction company. The TGMS testbed established on the extended region of Yong-dong Highway, for example, did not have consistent protocol between each automation levels and management levels without considering the functions and/or roles of each level. The management sever in each tunnel was simply networked to the TGMS server. Therefore, it is impossible to implement a new control algorithm as well as to integrate each other since each tunnel was constructed by different company. So, if the construction company is out of business, there is no way to maintain the corresponding tunnel effectively. In order to solve this problem, all the necessary standard protocols was established between automation level and management levels. These interface standards provide the clear classification between individual tunnel system and tunnel management system. So, even if construction company is different, its effect is minimized, so that it is expected to successfully establish PC based TGMS.

  • PDF

An Investigation of the Regulation, Design and Improvement of Domestic and International Ambulances (국내·외 구급차 규정, 디자인 및 개선에 관한 조사연구)

  • Shin, Dong-Min;Kim, Seung-Yong;Han, Yong-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.172-179
    • /
    • 2014
  • This research suggests that the regulation, design and improvement of domestic and international ambulances so that make the basis for the future ambulance in Korea. It is true that the diversification of current disasters, increasing elderly population, the increase in emergency patients, due to the lack of effective transfer system, emergency vehicle's performance problem, and the aging of ambulances cause have difficulty in providing effective emergency services in domestic country. Therefore, in order to improve the effectiveness of ambulance, the history of ambulance, other relevant provisions include international, design and directions to be improved were investigated, and also research directions of the ambulance are suggested in domestic country. In this research, suggests the following conclusions to improve domestic ambulance 1. Through standardization of the spacing and location of an ambulance is needed to maximize the treatment room. 2. The interior of the ambulance design for hygiene and infection control should be included. 3. Stretcher and equipment are designed to be fitted to each other should be standardized. 4. Especially during transfer maintain the road, noise, vibration, and shock-absorbing function to emphasize the importance. 5. The improvement of ergonomic design is necessary for the possibility of applying to many people.

A Study of the Voltage drops computation program on multi-distributed random loads (다중 분산부하 전압강하산정 프로그램 연구)

  • Kang, Cha-Nyeong;Kwon, Sae-Hyuk;Cho, Sung-Pil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.37-42
    • /
    • 2006
  • The voltage drop in electrical circuits causes a heat accumulation of wiring. This heat could change the specific character of an insulator and deteriorate the dielectric strength so that it could affect an electric leakage, an electric ant a power failure and a fire caused by the short circuit. Therefore optimal design for voltage drop in electrical wiring became an important factor to ensure the safety and economical efficiency of electrical facilities. So in this paper, I analyzed consequences that voltage drop affects in electrical wiring in multi-distributed system used for low electrical system such as road lights, Building, subway station which needs securities for the public society. And I proposed voltage drops computation program and optimal design to ensure the safety and economical efficiency.

  • PDF

Performance test of scale-up $20Nm^3/hr$ scale hydrogen generator for hydrogen station (수소스테이션용 $20Nm^3/hr$급 수소제조장치 스케일-업 및 성능시험)

  • Oh, Young-Sang;Baek, Young-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.37-42
    • /
    • 2006
  • In this study, $20Nm^3/hr$ scale compact hydrogen generator which can be apply to the hydrogen station was tested for hydrogen station application. $20Nm^3/hr$ scale compact hydrogen generator was developed by upgrading concept of stacking plate reactor from former $20Nm^3/hr$ scale plate hydrogen generator. concepts for improving system efficiency and performance include such as idea of heat recovery from the exhaust, exhaust duct which is especially design for plate type reactor reinforcement of insulation, enlargement of heat exchange area of reactor, introduction of desulphurizer reactor and PROX rector in a compact design, introduction of back fire protection structure of plate burner and so on, We can learn that final prototype of scale-up $20Nm^3/hr$ scale compact hydrogen generator can be operated steadily in 100% road at which over 94% of methane conversion(S/C=3.75) was obtained. In case of making up the weak point, we expect that it is possible to apply to hydrogen station by way of showing an example.

  • PDF

A Spatial Analysis about Arrival Delay and Dispatch Distribution of the 119 Rescue-Aid Service utilizing GIS - Gyeongsangbuk-Do Case Study - (GIS를 활용한 119 구조구급서비스의 도착지체 및 출동배치에 대한 공간분석 - 경상북도 사례 연구 -)

  • Oh, Chang-Seok;Lee, Seungwon;Lee, Inmook;Kho, Seung-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1D
    • /
    • pp.13-22
    • /
    • 2012
  • The 119 emergency rescue-aid service operated by Korean government is a very valuable in a society and its importance is growing in Korea as an aging society. Especially, the emergency vehicle's arrival time to accidents place is an important variable which affects initial emergency measure for patients and it depends on the road network attributes, such as emergency service station's location, accessibility to accidents place and so on. This study aims to analysis the emergency vehicles' arrival delay and the dispatch station in the viewpoint of efficiency utilizing the real rescue-aid activity data. We analyzed the dispatch distribution of the emergency rescue-aid service at first. And we analyzed high accident rate locations not involved in the fixed radius of rescue-aid service stations and display GIS map showing regions have been delayed. The input data of the road network speed is based on the KTDB (Korea Transportation Database) and historical rescue-aid data is from Gyeongsangbuk-do's fire service headquarters.

Fingerprint of Carcinogenic Semi-Volatile Organic Compounds (SVOCs) during Bonfire Night

  • Pongpiachan, Siwatt
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3243-3254
    • /
    • 2013
  • It is well known that increased incidences of lung, skin, and bladder cancers are associated with occupational exposure to PAHs. Animal studies show that certain PAHs also can affect the hematopoietic and immune systems and can produce reproductive, neurologic, and developmental effects. As a consequence, several studies have been attempted to investigate the fate of PAHs in atmospheric environment during the past decades. However, there is still a lack of information in regard to the atmospheric concentration of PAHs during the "Bon Fire Night". In this study, twenty-three polycyclic aromatic hydrocarbons and twenty-eight aliphatics were identified and quantified in the $PM_{10}$ and vapour range in Birmingham ($27^{th}$ November 2001-$19^{th}$ January 2004). The measured concentrations of total particulate and vapour (P+V) PAHs were consistently higher at the BROS in both winter and summer. Arithmetic mean total (P+V) PAH concentrations were $51.04{\pm}47.62$ ng $m^{-3}$ and $22.30{\pm}19.18$ ng $m^{-3}$ at the Bristol Road Observatory Site (BROS) and Elms Road Observatory Site (EROS) respectively. In addition arithmetic mean total (P+V) B[a]P concentrations at the BROS were $0.47{\pm}0.39$ ng $m^{-3}$ which exceeded the EPAQS air quality standard of 0.25 ng $m^{-3}$. On the other hand, the arithmetic mean total (P+V) aliphatics were $81.80{\pm}69.58$ ng $m^{-3}$ and $48.00{\pm}35.38$ ng $m^{-3}$ at the BROS and EROS in that order. The lowest average of CPI and $C_{max}$ measured at the BROS supports the idea of traffic emissions being a principle source of SVOCs in an urban atmosphere. The annual trend of PAHs was investigated by using an independent t-test and oneway independent ANOVA analysis. Generally, there is no evidence of a significant decline of heavier MW PAHs from the two data sets, with only Ac, Fl, Ph, An, 2-MePh, 1+9-MePh, Fluo and B[b+j+k]F showing a statistically significant decline (p<0.05). A further attempt for statistical analysis had been conducted by dividing the data set into three groups (i.e. 2000, 2001-2002 and 2003-2004). For lighter MW compounds a significant level of decline was observed by using one-way independent ANOVA analysis. Since the annual mean of $O_3$ measured in Birmingham City Centre from 2001 to 2004 increased significantly (p<0.05), it may be possible to attribute the annul reduction of more volatile PAHs to the enhanced level of annual average $O_3$. By contrast, the heavier MW PAHs measured at the BROS did not show any significant annual reduction, implying the difficulties of 5- and 6-ring PAHs to be subject to photochemical decomposition. The deviation of SVOCs profile measured at the EROS was visually confirmed during the "Bonfire Night" festival closest to the $6^{th}$ November 2003. In this study, the atmospheric PAH concentrations were generally elevated on this day with concentrations of Fl, Ac, B[a]A, B[b+j+k]F, Ind and B[g,h,i]P being particularly high.

Pattern Analysis for Urban Spatial Distribution of Traffic Accidents in Jinju (진주시 교통사고의 도시공간분포패턴 분석)

  • Sung, Byeong Jun;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.99-105
    • /
    • 2014
  • Since traffic accidents account for the highest proportion of the artificial disasters which occur in urban areas along with fire, more scientific an analysis on the causes of traffic accidents and various prevention measures against traffic accidents are needed. In this study, the research selected Jinju-si, which belongs to local small and medium-sized cities as a research target to analyze the characteristics of temporal and spacial distribution of traffic accidents by associating the data of traffic accidents, occurred in 2013 with the causes of traffic accidents and location information that includes occurrence time and seasonal features. It subsequently examines the spatial correlation between traffic accidents and the characteristics of urban space development according to the plans of land using. As a result, the characteristics of accident distribution according to the types of accidents reveal that side right-angle collisions (car versus car) and pedestrian-crossing accident (car versus man) showed the highest clustering in the density analysis and average nearest neighbor analysis. In particular, traffic accidents occurred the most on roads which connect urban central commercial areas, high-density residential areas, and industrial areas. In addition, human damage in damage conditions, clear day in weather condition, dry condition in the road condition, and three-way intersection in the road way showed the highest clustering.

An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel (도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Yoon, Chan-Hoon;Kim, Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • An experimental study was carried out on a reduced scale model tunnel to investigate the efficiency of disaster prevention at underground and ground ventilation equipments for the fire in road tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was manufactured. The vertical shafts that are used in the analysis of efficiency of disaster prevention are the two models that had considered when the real tunnels are designed and the amounts of smoke exhaust are applied the miniature of the real tunnels' smoke exhaust, 560 and $280\;m^3/s$. As the result of analysis, it is the possible the emissions of the entire quantity of CO gas through the vertical shafts. In the ground ventilation equipments, the concentration of CO is discharged 2.23~2,73 ppm smaller than the underground ventilation equipments. And the temperature rise in the ground ventilation equipments is $0.53{\sim}0.94^{\circ}C$ lower than in the underground ventilation equipments because of a cooling effect of the surface of the tunnel wall. As a result of analysis of CO concentration and the temperature rise in the modeling ventilation equipment, the position of ground ventilation equipment is more effective than the underground ventilation equipment in disaster prevention measures.

Numerical analysis on effect of hole size on Emergency Evacuation Support System (수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석)

  • Kim, Ji Tae;Park, Won Hee;Lee, Duck Hee;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.324-329
    • /
    • 2020
  • The emergency evacuation support system provides a safe means of evacuation by preventing the inflow of smoke through the formation of a smoke shield curtain in fire situations and pressurizing fresh air to the inside of the smoke shield curtain. In this study, numerical analysis was performed to examine the effects of the hole size on the flow inside the smoke curtain. As the air supply size decreased, the flow rate through the air supply was formed relatively uniformly from the inlet to the outlet length of the emergency support system. In addition, the size of the air supply hole was more than 20 mm, the flow rate was very low near the outlet, so the air supply hole size should be smaller than 20 mm. In addition, the minor loss of the air supply hole was calculated to be K = 1.5 from the numerical results. Therefore, the proper design of an emergency evacuation support system is possible using the flow characteristics according to the size and minor loss of the air supply hole.

The Living Theatre: A History Study of Its Birth and Death (리빙 씨어터: 탄생과 소멸에 관한 사적(史的) 연구)

  • Kim, Jung-hyo
    • Journal of Korean Theatre Studies Association
    • /
    • no.40
    • /
    • pp.207-237
    • /
    • 2010
  • Concentrating on the birth, life, and death of the Living Theatre, almost half a century avant-garde group, the primary purpose of this study at large is to explore its counter-cultural philosophy. While taking a chronological form adapting the biological order, the paper focuses on the troupe's productions: , , , , and . Through out these productions the philosophy of the Living Theatre seemed to included communal, anti-intellectual, politically radical, generally Utopian, and proselytizers for sexual freedom. The history of the Living Theatre interestingly parallels the history of the Beck's theatre in occupation and shut down. The first New York theatre was closed by fire inspectors for instance. The second theatre was declared unsafe, and locked up by the Building Department. The third theatre was seized by the IRS, consequently shut down. In 1984, after more than 25years from the third building, the Living Theatre settled once again on East Third Street in Manhattan. The theatre was however evacuated by the New York City Fire Department in 1993 and once more took to the road. With these struggles, the Becks' profound aspiration of the counter-cultural insurgency came to harden as strong as 'iron' in some ways. With the outstanding components of counter-cultural philosophy and style, the Living Theatre, in the course of the transformation, absorbed and then reflected virtually every phase for the Living Theatre were vehicles for more than just aesthetics. The group seemed to propagandize its beliefs rather performing productions. Accordingly, both on and off-stage action of the Living Theatre caused great controversy either through political activism of individual members or through the unconventional collective life style. No avant-garde theatre company was more emblematic of the rebellious spirit of the sixties than the Living Theatre. Like the first great transformation, the Becks' encounter, their personal values and the form of theatre they created had blended 'so inextricably that the vitality of each was dependent on the other.' The Becks always urged unity and harmony at all levels of human life, but not at any price. The anticapitalist ideal inspired the Becks to promote a politically motivated campaign throughout their productions. They believed the revolution is desirable but in the state of non-violence and the expansion of human consciousness. Julian Beck's gravestone identifies his as pet, painter, actor, and anarchist. The Living Theatre was a 'small umbrella' under which the Becks and its members could breath and unfold their dream on stage or in the street.