• Title/Summary/Keyword: Fire Road

Search Result 201, Processing Time 0.022 seconds

A Study on the Model Experiment for Smoke Flow in Road Tunnel Fire (도로터널 화재발생시 연기유동에 관한 축소모형실험 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kang, Se-Gu;Ahn, Kyung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2004
  • In this study, smoke movement in tunnel fire with natural and longitudinal ventilation systems has been investigated. Reduced-scale experiments were carried out under the Froude scaling using 14.55kW fire source with a wick and experimental data is obtained with 1/18 model tunnel test. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gas was measured at emergency exit point. The results show that refuge time for 225m intervals of emergency exit in case of natural ventilation systems is 256 seconds and critical velocity for sufficient back-layer prevention is 2.8m/s for fire strength of 20MW.

  • PDF

The study on application of automatic monitor system for initial fire suppression in double-deck tunnel (대심도 복층터널 초기화재 진압을 위한 자동모니터 소화설비의 적용성 연구)

  • Yoo, Yong-Ho;Park, Sang-Heon;Han, Sang-Ju;Park, Jin-Ouk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.419-429
    • /
    • 2016
  • In a bid to avoid the economic loss resulting from traffic jam in urban area, a deep underground road at 40 m depth has been considered and the first class disaster prevention facilities shall be applied according to domestic guideline. Automatic-monitoring fire extinguishing system designed to use for fire fighting has been widely applied at home and abroad. Recently development and commercialization through theoretical and experimental research to apply to road/railroad sector have been underway. Based on such performance of automatic fire extinguishing system, technical/economic analysis of existing water spray systems was conducted and as a result, it has demonstrated the superiority in terms of fire suppression as well as in cost efficiency. Then to commercialize this system, more diverse studies that will incorporate the characteristics of domestic tunnels are needed and should the system be promoted through institutional improvement, it's expected to become one of the advanced nations with own original technology in a life safety system industry throughout the world.

Night fire fighting helicopters operations and Aviation Safety (야간산불진화 헬기 운영과 항공안전)

  • Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.1
    • /
    • pp.145-151
    • /
    • 2014
  • Not only in Korea, but also in other countries, most helicopter accidents occur at low altitude. Analysis on accidents data collected both in Korea and other countries has brought two conclusions. Firstly, helicopter operations during the night hours carries a high risk. Secondly, the most common cause of night hour operations is loss of control due to the flight illusion. As an operation relying on a night vision in particular has a very high accident hazard, accompanying instruments such as NVG are ought to be provided. Hence, a thorough preparation and inspection on missions for night forest fire extinguishing should be required and perfect guidelines/road maps and enough training programs for the operation should be provided before the engagement in missions.

A Study on the Roadmap Design for Electrical Safety Technology (전기안전기술 로드맵 설계 연구)

  • Shin, Heung-Sik;Lee, Jae-Chon;Lee, Bung-Gil
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.3
    • /
    • pp.1-7
    • /
    • 2007
  • A roadmap for Electrical Safety Technology has been designed based on the study that has been contributed by the specialists, professors and researchers in electral safety field. The roadmap is divided into five major fields including, for instance, the electrical fire accidents roadmap. The other four roadmaps are for electrical shock accidents, electrical facilities accidents, electrical safety policies and electrical safety culture-education, respectively. Each roadmap has a purpose, a scope, and a technical characteristic. Following the roadmaps can result in significant reduction of electrical fire accidents, electrical shock accident victims and so forth. The result can also be utilized in guiding the planning and development of the future electrical safety technology.

An Experimental Study of Smoke Movement and Evacuation in Road Tunnel (도로터널내 연기거동 및 피난에 관한 실험적 연구)

  • Kang Hyun-Wook;Lee Ho-Seok;Shin Young-Wan;Lee In-Ki
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.335-340
    • /
    • 2005
  • Recently, According to increased tunnel accident, a matter of concern in tunnel fire safety is on an interesting trend. In case of tunnel fire, Evacuation is a primary factor for refugee safety. Therefore safety measures should be taken to increase capability of evacuation. Evacuation walking speed and characteristics of movement in tunnel is differ from building or outdoor site so, these characteristics must be considered in tunnel safety planning. In this study has performed to evaluate the smoke movement and characteristics of evacuation by full-scale test method. and aimed for basic data establishment in characteristics of evacuation for tunnel safety system design.

  • PDF

A Study on the Development of Model and Application Case of Water Screen Effect for Fire Behavior Simulation in Road Tunnel (도로터널 화재성상 시뮬레이션을 위한 워터스크린 효과 모델개발 및 적용사례)

  • Han, Jung-Chul;Kim, Se-Jong;Kim, Dong-Eun;Kurioka, Hitishi;Ootuki, Masato;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.83-88
    • /
    • 2011
  • 워터스크린(이하 W/S)에 의한 화재방화시스템은 도로터널에 화재가 발생시, 공간에 수막을 사용하여 구획화하고, 열 연기의 확산을 억제하며 유해 부유입자를 세정함으로서 인간의 안전을 확보 및 구조물의 피해를 극소화 하는 시스템이다. 이 W/S에 의한 구획의 성능을 평가하기 위해, 1/2의 터널 모형에 의한 공간 내 열 성장 파악을 위한 화재 실험을 분석하였고, 그 결과, 천정 근방 온도 및 방사수열량으로서는 발열 속도의 크기, 풍속의 대소에 의하지 않고 약 80%의 저감율을 나타냈다. 또, 발생한 유해 부유입자 농도에 대해서는 약 60%, 화원 성질과 상태로서 발열 속도는 약30%의 W/S에 의한 저감 효과를 나타내었다.

  • PDF

A Study on the Model Experimet and MLZ Model Analysis for Predicting Fire Behavier in Road Tunnel (도로터널에서의 화재성상 예측을 위한 축소모형실험 및 MLZ모델 분석에 관한 연구)

  • Han, Jung-Chul;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.294-297
    • /
    • 2012
  • 본 연구는 MLZ을 활용하여 도로터널의 다양한 화재시나리오별 화재성상예측을 목적으로 1/20 Scale 모형실험을 통하여 소형차, 버스화재 시 FAN의 작동 비작동, 소형차 2대 직렬 병렬화재, 소형차 2대+버스 혼합 화재실험을 바탕으로 FAN작동시 배기구 방향으로 고온의 열기층이 생성됨을 확인하였다. 축소모형실험과 MLZ 해석결과를 비교하여 화원으로부터의 약 20m 정도의 이격거리부분 온도가 유사하게 나타났고, 시간별 온도분포를 확인한 결과 플래시오버 이전단계에 피난계획을 세우는 단계에서 예측이 가능했다.

  • PDF

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.171-174
    • /
    • 2010
  • 도로터널에서의 미분무수 소화시스템의 적용 가능성을 검토하기 위해 실물 화재 실험을 수행하였다. 적용된 화원은 실물 승용차 화재와 유류화재를 모사한 화원면적 $1.4m^2$의 heptane pool 화재이며, 기존 도로터널에 설치된 저압 물분무 시스템과 고압 미분부수 소화시스템과의 냉각효과 비교실험을 수행하였다. 도로터널 내의 환기조건을 구현하기 위해 실물모형 터널의 한 편에 터널 유속(0.9~3.8 m/sec 범위) 발생장치를 설치하였으며, 화원에서 하류 방향으로 터널 내 온도분포를 측정하였다. 실험 결과 1/5의 유량을 사용하는 고압 미분무수 소화시스템은 저압 물분무 시스템과 동등한 수준의 냉각효과를 보였다.

  • PDF

Review of fire resistance evaluation and fire resistance method of concrete segment lining for fire in tunnel (터널 내 화재발생에 대한 콘크리트 세그먼트 라이닝의 내화성 평가 및 내화방법에 대한 고찰)

  • Moorak Son;Juhyun Cheon;Youngkeun Cho;Bumjoo Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.121-139
    • /
    • 2023
  • Various tunnels such as road, subway, and railway are under construction and operation. Various types of linings are used for structural stability of tunnel structures, and concrete segment linings are mainly installed in TBM tunnel construction. In this paper, when a fire occurs in a tunnel, the impact on the concrete segment lining, which is the structure in the tunnel, and related standards, fire resistance evaluation and fire resistance method are investigated through literature review and related contents are presented. Through this, it is intended to provide an information for practitioners to secure the safety of concrete segment linings against tunnel fires.

A Study of Smoke Exhaust Rate for the Transverse Ventilation with Oversized Exhaust Ports in Road Tunnel (횡류식 대배기구 방식을 적용한 도로터널에서 화재시 최적배연풍량 선정에 관한 연구)

  • Yoo, Ji-Oh;Yoon, Sung-Wook;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.7-12
    • /
    • 2006
  • Recently, the application of transverse ventilation system with oversized exhaust ports has been increased in bidirectional road tunnel in order to improve smoke exhaust ability. Therefore, in this study, for decision of the optimal smoke exhaust rates in the transverse ventilation system, several standards of nations are compared and numerical simulations with variations of exhaust flow rates are carried out in terms of smoke spread distance by FDS ver. 3.1. As results, in the case of no internal longitudinal air velocity in tunnel, the smoke exhaust rate of $80m^{3}/s$ (the smoke generation rate at HRR of 20MW) is sufficient enough to limit the smoke spread within 250m in 6 minutes after the fire. However, in the case of the internal longitudinal air velocity at 2.5m/s, the smoke exhaust rate should be increased $130m^{3}/s$.