• 제목/요약/키워드: Fire Resistance Test

검색결과 390건 처리시간 0.027초

초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구 (A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete)

  • 백영운;육태원;박동수;김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

강구조 부재의 표면온도 산정 및 내화피복두께에 관한 연구 (Study on the Surface Temperature and Fire Protective Thickness for Structural Steel Elements at Fire Conditions)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.55-61
    • /
    • 2010
  • 건축물 주요구조부의 내화성능은 인명과 재산보호를 위해서 반드시 확보되어야 하고,일정 규모의 가열로에 의한 재하가열시험과 비재하가열시험으로 검증, 적용되고 있다. 이러한 내화성능의 검증에는 많은 비용, 시간이 소요되므로 합리적인 부재와 공법의 개발이 활발하게 이루어지지 못하는 실정이다. 따라서 본 논문에서는 H형강을 바탕으로 콘크리트 및 방화석고보드를 활용한 기둥부재와 보부재를 제안한 후, 각각을 표준온도가열곡선의 열원으로 강재의 표면온도를 계산하여 내화성능을 예측하였다. 또한 철근콘크리트 바닥을 대상으로 온도해석을 통하여 건축물의 내화성능기준별 적정 내화피복두께를 제시하였다.

강재보용 내화피복의 내화성능 평가단면에 대한 고찰 (Review on Fire Test Section of Fire Protection Coating for Steel Beam)

  • 전수민;김재준
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.49-55
    • /
    • 2016
  • 강구조용 내화피복은 내화성능평가를 통하여 내화구조로 인정을 받아야 사용할 수 있는데 기둥용 내화피복은 4면, 보용 내화피복은 3면을 가열하여 내화성능을 평가한다. 4면이 균등하게 가열되는 기둥과 달리 3면이 가열되는 보의 경우 비가열면인 상부의 온도가 가열면의 온도와 차이가 있을 것이 예상된다. 보용 내화피복 내화성능 평가시 비가열면의 온도도 포함되는데 비가열면의 온도가 부재의 온도와 유의한 차이가 있다면 온도측정 부위에 대한 신중한 검토가 필요할 것이다. 이에 본 논문에서 내화구조로 인정된 보용 내화피복의 내화성능시험결과를 분석하여 보용 내화피복 내화성능 평가단면의 타당성을 살펴보고자 한다.

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

Fire design of concrete encased columns: Validation of an advanced calculation model

  • Zaharia, R.;Dubina, D.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.835-850
    • /
    • 2014
  • The fire resistance of composite steel and concrete structures may be determined by using the simplified methods provided in EN 1994-1-2. For the particular situations not covered by the standard, an advanced calculation model might be applied, using special purpose programs for the analysis of structures in fire. The validation of these programs has always been an important issue for software developers, but also for designers and authorities. Clause 4.4.4 from EN 1994-1-2 refers to the validation of the advanced calculation models and states that these models must be validated through relevant test results. The paper presents the calculation of fire resistance of the composite columns in a high-rise building built in Romania, and focusses on the validation of the calculation model (computer program SAFIR), for this particular case. This validation, asked by the Romanian authorities, considers the available experimental results of a fire test, performed on a similar composite steel-concrete column.

내화피복 강재의 내화성능 평가 예측에 관한 연구

  • 성시창
    • 방재기술
    • /
    • 통권17호
    • /
    • pp.5-9
    • /
    • 1994
  • With a rapid development of economy, more high-rise buildings are being constructed in large cities than before. As a result steel members such as beams, columns make a great role of the building construction, and the need of them to be protected to have enough fire resistance is in-creasing . But conducting a real fire test to all the members is almost impossible. So prior to do conduct a real fire test of the protected steel members, evaluating the fire resistant rating of them by means of their specific properties might be economical things. This study is aimed to introduce the fire resistant rating of protected steel members without a real fire test through the related studies and data.

  • PDF

건식화 P0SCO E&C Fire Board (PFB)공법 개발에 관한 연구 (A Study on the Development of a Dry PFB Method with High Fire Resistance)

  • 김우재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.953-956
    • /
    • 2008
  • 국내 초고층 프로젝트의 증가에 따라 필연적으로 고강도 콘크리트의 사용이 증가되고 있다. 콘크리트의 강도가 증가됨에 따라 화재시 단면결손을 유발하는 폭렬의 경향성이 커지고, 콘크리트부재 내부의 온도를 현저하게 증가시키며 심각한 구조적 손상을 유발할 수 있다는 문제점이 대두되었고, 정부에서도 2008년 7월부터 고강도 콘크리트의 내화성능 관리기준을 시행하고 있다. 이에 국내 각 건설사들은50MPa 이상의 고강도 콘크리트에 대하여 폭렬방지 대책을 수립 중에 있다. 본 연구소에서는 신축공사 및 리모델링공사에도 적용이 가능한 고강도 콘크리트 폭렬방지 공법인 PFB (Posco E&C Fire Board) 공법을 개발하여 지속적인 공법 개선에 노력하고 있다. 본 연구는 고강도 콘크리트 폭렬방지 대책으로 개발한 PFB 공법 개발에 대한 일반사항, 현재 건식화 공법 개발 및 당사 PJT적용 현황에 대한 내용을 기술하고자 한다.

  • PDF

콘크리트내에 표면매입 보강된 FRP의 내화성능 향상을 위한 내화단열재 열저항성능 평가 (Evaluation on the Thermal Resistance Capacity of Fire Proof Materials for Improving Fire Resistance of Near-Surface-Mounted FRP in Concrete)

  • 연제영;서수연
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.51-58
    • /
    • 2014
  • 본 연구에서는 철근콘크리트 구조의 FRP를 이용한 보강에서 낮은 내화성능을 개선하기 위한 방안을 찾기 위하여, 보강된 FRP의 외부를 내화보강하는 방법에 대한 내화실험을 실시하였다. 특히 철근콘크리트 부재의 피복에 홈을 형성하여 FRP를 매입하는 보강 즉, NSM 보강을 대상으로 하였다. 실험에서의 주요 변수는 보강방법과 사용 내화재료로서, Perlite계 재료를 표면에 분사하여 보강하는 방법, Calcium silicate계 보드로 표면에 부착하는 방법, 그리고 추가로 홈내부에 Polymer mortar 또는 Calcium silicate조각을 삽입하여 보강하는 방법으로 보강한 뒤 가열로 내부의 온도변화에 따른 열전달을 관찰하였다. 실험결과, Perlite계 내화뿜칠로 표면을 보강하는 경우보다 Calcium Silicate계 내화보드로 표면을 보강하는 방법이 효과적인 것으로 나타났다. 홈 내부의 에폭시가 유리전이온도에 도달할 때의 외부 표면온도 $820^{\circ}C$까지 내화단열성능을 확보할 수 있는 것으로 나타났다.

폴리믹스 혼입에 의한 고강도 콘크리트의 폭렬방지 방안에 관한 연구 (A study on the fire resistance properties of high strength concrete by incorporation of Polymix fiber)

  • 김정진;이상현;이주호;신재경;박종호;정용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.395-396
    • /
    • 2010
  • 본 연구는 최근 국내 초고층 건물의 고강도콘크리트 화재시 내화성능 확보와 관련하여 자체 연구개발한 폴리믹스(PP섬유 + 폴리머분말)를 적용 80MPa 고강도 콘크리트에 대한 내화성능 확인 실험을 실시함으로써, 초고층 펌프압송이 가능한 초고층용 고내화콘크리트를 개발하는데 그 목적이 있다.

  • PDF

A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험 (Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types)

  • 박우창;송창용
    • 한국해양공학회지
    • /
    • 제33권4호
    • /
    • pp.340-349
    • /
    • 2019
  • In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.