• Title/Summary/Keyword: Fire Protection System

Search Result 566, Processing Time 0.023 seconds

A study Fire Protection and Evacuation System for Buildings (건축물의 방화 및 피난계획에 관한 연구)

  • 이경수;임만택
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.9-16
    • /
    • 1988
  • This study is intended to suggest some ideal measures available in the course of construction from the viewpoint of an architect to reduce damage of human lives and Properties caused by fire accidents in buildings. For this study, 7 buildings burnt by conflaguration in Seoul during the years of 1985 and 1987 are picked up, and 105 withnesses, who were present in one of them at them at fire, are traced for personal interview and respones to the written questionaire about 5 main issues; their perceptional behaviour, their emotional state at that time, their reactions to avoid danger, their escape routes, and their usual awareness to prevent fire. Some desirable measures suggested here are ;making Provisions to install fire centers in large buildings and underground structures in the fire fighting law, and requlating to compose fire units appropriate to the quantity of combustibles inside, limit the length of a blind corridor, furnish balustrade, and limit the width of the landing of the stairs in building code and regulations. Such measures should be considered from the time of planning to construct a building, and some drill and education in fire prevention is demanded for the occupants of the buildings too.

  • PDF

A Study on Damage Assessment for Fuel Cell Facilities in Gas Stations (주유소 내 연료전지설비에 대한 사고피해예측 연구)

  • Sung Yoon Lim;Jang Choon Lee;Jae Hoon Lee;Seung Ho Choi
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.1
    • /
    • pp.71-80
    • /
    • 2023
  • Fuel cells are low-carbon power sources that can expand distributed energy system and electric vehicle charging infrastructure when installing fuel cells in gas stations. In order to ensure safety for fuel cells in gas stations, quantitative risk assessments were conducted after deriving accident scenarios based on accident data of domestic and foreign gas stations and fuel cells. It calculates the expected extent of damage from fire and explosion that can occur in reality, not the worst accident scenario, and analyzes the damage impact. The separation distance of more than 9.0 m from a dispenser, 15.5 m from a car under refueling, 4.1 m from the ventilation pipe, 1.1 m from the gas adjustment device prevent the severe damage caused by the expected accident. This study result can be used to deploy fuel cells in gas stations and establish safety measures.

A Study on the Design Program Development of the Carbon Dioxide Fire Extinguishing System Using an Optimization (최적화 기법을 이용한 이산화탄소 소화설비의 설계프로그램 개발에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.1-9
    • /
    • 2014
  • In this study, it was developed to the design program optimization the design factors of the carbon dioxide fire extinguishing system on the basis of design theory for the carbon dioxide fire extinguishing system, national emergency management agency (NEMA) notice No. 2012-11, KS B 6261 and steepest descent method of optimization. The design program was developed to C++ compiler based on established the logic and algorithms and was to operate on the Windows operating system. The optimization of design factors for the carbon dioxide fire extinguishing system are minimized subject to constraint on agent flow rate, emission time and design variables (pipe size etc.). It was verified to the design program performance for test system, and it was provided to the foundation for optimal design in fire fighting field. Also, it is considered to improve the efficiency of the fire extinguishing system and to maximize of fire suppression as the construction of the carbon dioxide extinguishing system based on the optimal design factors.

Experimental Study on the Suppression Performance of Sprinkler Systems in Rack-type Warehouses (랙크식 물류창고의 스프링클러설비 소화성능에 관한 실험연구)

  • Choi, Ki-Ok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.44-50
    • /
    • 2019
  • In rack-type warehouses, it is difficult to extinguish fires effectively using sprinkler systems because high fire load commodities are stacked vertically and densely. In this study, an actual size rack structure was constructed and the effectiveness of the fire extinguished by the sprinkler system was confirmed through fire tests according to the type and arrangement of the sprinkler head in the rack structure. Through this study, to effectively suppress fires in rack-type warehouses, it is necessary to use sprinkler heads with a volume of more than 115 LPM and sprinkler heads need to be installed at the diagonal corner positions of the commodities of each rack.

A Study on the Recognition of Fire Construction Surveillance System : Focused on the Stakeholders (소방공사감리제도의 인식에 관한 연구 : 이해당사자를 중심으로)

  • Lee, Ranny;Jeong, Kyeon-Sik;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.133-143
    • /
    • 2014
  • The purpose of this article is to search stakeholders' recognition related to Fire Construction Surveillance system; a client(order), fire fighting officer, supervision company, construction company, design company, other. The paper provides 4 important things. Firstly, a client(order) suggested the lowest recognition in the needs about the need of separation order, that of contract for any construction work limited registered companies, and that of standard price for engineering.. Secondly, the design company is lowest recognition in guidance and control participating in construction-design phase. Thirdly, the design company is lowest in adjustment about manpower-allocation according to allocation criteria of technical manpower. Fourthly, a client(order) and supervision company are relatively lower than other stakeholder in necessity on special education and training system for auditor in fire protection construction. Almost all related matters are related to more or less stakeholders' interest.

A Study on the Development, Performance and Reliability Certification for Fire Detection System in Outdoor Area (옥외형 화재경보시스템의 개발과 성능시험에 관한 연구)

  • Baek, Dong-Hyun;Ghil, Min-Sik
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper is concerned with the Performance and Reliability Certification for fire detection system in outdoor area such small and middle sized cultural assets, natural monument and outdoor facilities. Especially, if a fire were to occur in vulnerable area, it is difficulty to detect a fire. therefore we propose a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. for Adoption of Intelligent Fire Detection System with movable and unmanned function breaking from the existing Conventional Fire Detection System, this Range of R&D includes the Performance test, Function test, Field test, Flame Detection test and EMI/EMS Compliance test. the Result data of Performance test, Function test and Field test is generally good during 3 months. also we checked that thermal variation test and EMI/EMS compliance test are good result data within allowable range. As a result of general test, we verified improvement results that the measure distance of fire detection extend 75 m, the Power of waiting time increase 4 hours, the Power of operation time increase 3 days and the context awareness with video as well as sensors.

A Study on Device Development for Electrical Fire Protection on Open Phase of Three-Phase Motor (3상 전동기 결상에 의한 전기화재 보호를 위한 장치 개발 연구)

  • Choi, Shin-Hyeong;Kwak, Dong-Kurl;Kim, Jin-Hwan
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.61-67
    • /
    • 2012
  • In the three-phase power system using the three-phase motor, when any one-phase is open-phase, the unbalanced current flows and the single-phase power supplied by power supply produces overcurrent to motor coil. As a result, the enormous damage and electrical fire can be given to the power system. Recently, the thermal over-current relay (THR) or electronic motor protection relay (EMPR) is mostly used as the open-phase detection device of the three-phase motor. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for openphase protection using semiconductor devices. Therefore, the proposed open-phase protection device (OPPD) enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight. As a result, the proposed OPPD protects the three-phase motor, minimizes the electrical fire from openphase, and contributes for the stable driving of the power system. The performance and confidence of the proposed OPPD is confirmed by a great variety of the experiments of operation characteristic.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

A Study on the Development of a Duct-dedicated Intelligent Fire Detection System (덕트전용 지능형 화재감지시스템 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Gun-Ho;Lee, Chun-Ha;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.39-48
    • /
    • 2015
  • This research was done to develop a duct-dedicated intelligent fire detection system to prevent fires and minimize fire damage of the industrial duct having a high fire risk. To understand the fire hazards of the ducts, the analysis was centered on the Daegu Textile Industrial Complex, where industrial ducts are used frequently. With this in the background, dedicated fire detectors and fire alarm control panel, which can prevent fires and to minimize fire damages to the ducts, were designed and produced, after which the performance was confirmed. As a result of performance experiments, it was shown that a duct-dedicated intelligent fire detection system had excellent adaptability and temperature accuracy. Through real-time temperature monitoring of the inside of the ducts, it was confirmed that duct fires could be efficiently extinguished by stepwise control of linkage facilities according to the setting temperature.