A Study on the Design Program Development of the Carbon Dioxide Fire Extinguishing System Using an Optimization  

Lee, Dong-Myung (Depart. of Fir Protection Administration, Kyungmin Univ.)
Publication Information
Fire Science and Engineering / v.28, no.3, 2014 , pp. 1-9 More about this Journal
Abstract
In this study, it was developed to the design program optimization the design factors of the carbon dioxide fire extinguishing system on the basis of design theory for the carbon dioxide fire extinguishing system, national emergency management agency (NEMA) notice No. 2012-11, KS B 6261 and steepest descent method of optimization. The design program was developed to C++ compiler based on established the logic and algorithms and was to operate on the Windows operating system. The optimization of design factors for the carbon dioxide fire extinguishing system are minimized subject to constraint on agent flow rate, emission time and design variables (pipe size etc.). It was verified to the design program performance for test system, and it was provided to the foundation for optimal design in fire fighting field. Also, it is considered to improve the efficiency of the fire extinguishing system and to maximize of fire suppression as the construction of the carbon dioxide extinguishing system based on the optimal design factors.
Keywords
Optimization; Steepest descent method; Carbon dioxide fire extinguishing system; Design program; Optimal design;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 NEMA, "The Certification Performance of Design Program and the Technical Standard of Product Inspection of Gas Extinguishing Systems", NEMA Notice No. 2012-11 (2012).
2 E. J. Haug and J. S. Arrora, "Applied optimal Design", pp. 15-94 (1979).
3 Korean Industrial Standard, "KS B 6261 Fixed High- Pressure Carbon Dioxide Fire Extinguishing Systems", Korean Standards Association (2007).
4 D. M. Lee and W. K. Lim, "A Development Design Program and Test Module of the Carbon Dioxide Fire Extinguishing System", Proceedings of 2012 Autumn Annual Conference, Korean Institute of Fire Science & Engineering, pp. 267-270 (2012).
5 W. K. Kim, "Quantity of the Agent in the Piping System of Low Pressure Carbon Dioxide Extinguishing Systems", Proceedings of 2011 Spring Annual Conference, Korean Institute of Fire Science & Engineering, pp. 136-139 (2011).
6 S. M. Lee, S. W Moon and S. H. Ryu, "A Study on verifying the reliability of CO2 Fire Extinguishing Systems through the Direct Discharge Test", Proceedings of 2012 Spring Annual Conference, Korean Institute of Fire Science & Engineering, pp. 155-158 (2012).
7 NEMA, "National Fire Safety Code of Carbon Dioxide Fire Extinguishing System", NEMA NFSC 106 (2012).
8 D. M. Lee, "A Study on Dynamic Optimization of Machine Structures", In-Ha University (1997).
9 C. Y. Choi and S. C. Ko, "A Practical Approch for Optimal Design of Pipe Diameters in Pipe Network", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 18, No. 8, pp. 635-640 (2006).   과학기술학회마을
10 S. D. Shon and S. J. Lee, "A Study on the Optimum Design Program for Steel Truss Using Discrete Design Variables", Proceedings of KASS Symposium-Spring, Vol. 8, No. 1, KASS, pp. 111-118 (2011).
11 NFPA, "Standard on Carbon Dioxide Fire Extinguishing Systems", NFPA 12A (2006).
12 SFPE, "SFPE Handbook of Fire Protection Engineering", Third Edition, NFPA (2002).
13 P. J. DiNenno, E. W. Forsseli, M .J. Ferreira, C. P. Hanauska and B. A. Johnson, "Modeling of the Flow Properties and Discharge of Halon Replacement Agents", NFPA Tehnical Papers, pp. 117-129 (1994).