• Title/Summary/Keyword: Fire Protection Safety Management

Search Result 187, Processing Time 0.021 seconds

Analysis of Fire Risk through Battery Fire Cases and Experiments of Wearable Devices (웨어러블 기기의 배터리화재사례와 실험을 통한 화재위험성 분석)

  • Lee, Jung-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.47-55
    • /
    • 2020
  • This study analyzed ignition probability about Lithium-polymer batteries of what variously were being produced wearable devices recently. The study analyzed ignition probability by PCM(Protection Circuit Module) operating state and overcharged, over-discharged, exposed to high temperatures of Lithium polymer batteries, analyzing wearable devices on the market. Then it classified experimental results to implement analysis comparison about weight, X-ray imaging, battery decomposition. With these experiments, the study analyzed combustion-possibility and fire patterns. These statistics will be used to measure and verify the cause of a fire when identify wearable devices using Lithium-polymer batteries.

A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron (전기다리미의 발화원인 판정에 관한 현상학적 고찰)

  • Mun, Yong-Soo;Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

Problems and Solutions for Securing Fire Resistance Performance in Fire Protection doors (방화문 내화성능 확보에 대한 제도적 문제점 및 해결방안)

  • Kim, Juseong;Kim, Siwon;Cho, Youngduk;Kim, Jaejun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • Among many fire-related laws and standards such as fire protection, fire doors are important facilities that play a role in preventing the spread of fire and smoke in the event of fire, thereby minimizing human casualties. Accordingly, the standards for performance required by applicable laws and regulations and related enforcement rules and notices have been continuously raised and the corresponding performance must be secured. However, due to the shortcomings of the relevant laws and systems, the test results of the fire doors confirmed that there was a risk of passing products. In this study, the criteria for fire-related performance were analyzed, and the performance required by other laws, in addition to simple fire protection, was identified, the criteria were organized, and the complex performance required was clearly.

Safety Performance Assessment for a Aged Building (노후 건축물의 안전성능 평가항목)

  • Kwon Dong-Chan;Lee Yong-Jae;Lee Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.296-300
    • /
    • 2004
  • As a building aged, overall performance considering structural safety, equipment safety and fire safety is lowering gradually. Since the building performance and the overall value of the building change as time elapse, exact safety performance of the building should be evaluated not only maintaining the building efficiently and also preventing disputes between buyer and seller of the building. We suggest major elements for assessing building's safety performance through surveying literatures, interviewing experts, reviewing existing assessment models, The assessment elements proposed here ate comprised of structural safety, equipment safety, fire safety, fire protection and fire escape, etc. This study helps to make a safety performance assessment criteria for a building.

  • PDF

A Study on the Problems and Character for Management of Fire Prevention at the Wholesale Markets (도매시장 화재안전관리 측면에서의 특성 및 취약요소에 관한 연구)

  • Park, Jae-Sung;Im, Jae-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.150-158
    • /
    • 2010
  • There are lots of buildings with their deterioration in wholesale markets which have high concentration that can cause big fire due to difficulty of installing fire protection system in fire compartment, absence of safety awareness, access by many and unspecified people. There had been big fire that caused by these kind of fire weakness such as Seomun Market's in 2005 which costed tens of millions dollar, Dongmun Shopping District’s with 7 casualties. Now counter-measure against these fire is urgently needed. This study drew characteristic of current condition of wholesale markets and the one classified by main agent, fire cases and prevention of fire through statistical data. Also, current condition of fire prevention management and actual state were investigated by conducting a survey of person in charge of fire prevention and current practician. As a result, it was shown that securing professionalism of fire prevention, improvement of structural weakness of buildings, obtaining reliability on performance of fire protection system and internal fire education against practician in the market are needed.

The A Test of Physical Property of Fire Extinguishing Agent according to Durable Years of the Third-class Powder Extinguisher (제3종 분말소화기의 내용연수에 따른 소화약제의 미세도 실험)

  • Ju-Dal, Son;Ha-Sung, Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.4
    • /
    • pp.117-124
    • /
    • 2022
  • This study collected powder extinguishers with 6-10 years of elapsed life from January 2012 to January 2017 in market, factory, and apartment areas to experiment with changes in fineness and to examine the characteristics of extinguishing power. First, in the case of ABC powder, 98.3 wt% of the 8-year market area and 98.6 wt% of the 10-year apartment complex were found to be inappropriate in the first, second, and third arithmetic average analysis of the powder extinguisher from 6 to 10 years. That is, the fine distribution and size of the powder extinguishing agent particles should be managed within an appropriate range. It is analyzed that the powder fire extinguisher may experience a change in the fineness of the powder depending on the external environment exposure, placement, management status, and age of use, resulting in a decrease in digestive power or inability to radiate. Second, the fire extinguisher cannot be used in the initial fire suppression depending on the place of deployment, the environment of deployment, the progress of the number of years of use, and maintenance, so it is necessary to strengthen the device that enables fire extinguisher maintenance and inspection. Third, in the manufacturing process, the charging method should also be reviewed in consideration of the conditions of the workplace, the humid season, and the rainy environment.

A Study on Investigation into Actual Condition of Management in Fire Protection System -Apartment Buildings, Shopping Center, Office Buildings- (소방시설 관리실태조사에 관한 연구 -공동주택, 상가건축물, 사무소건축물-)

  • 김홍배;한상민;이영재;조병선
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.70-76
    • /
    • 2001
  • In a daily life these days, the safety and the comfort are considered very important. As the same as other areas, the good maintenance of fire protection systems and the fire drill plans in buildings can minimize the loss of human life and the property in case of fires. In this paper, a survey has been conducted to investigate the maintenance status of the fire protection systems of apartment buildings, shopping center and office buildings. Both practical procedures for checking the systems and for fire drills and strategic plans to minimize the losses in case of fires are suggested by analyzing how well the occupants in the buildings acknowledge the evacuation drills when the fire occurs.

  • PDF

Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint (도료의 주성분에 따른 편백 합판의 방염성능 비교 분석)

  • Soo-Hee Lim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.

A RESEARCH ON EFFECTIVE FIRE/DISASTER PROTECTION OF UTILITY TUNNEL IN KOREA

  • Park, Hung-joo;Son, Bong-sei;Jee, Nam-yong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.404-412
    • /
    • 1997
  • The pipes and cables buried below ground, which may have helped to improve city landscape, is becoming direct and indirect causes for various kinds of disaster in Korea. Every advantage from the use of utility tunnel can not be converted in a dollar since there is associated huge contribution to safe urban environment. The Korean government has a certain role to play in helping promote utility tunnels for the past years. Most recently, many utility tunnels have been being checked to find out safety level, especially fire safety level, and main problems and shortcomings are checked out as a result of this survey. Because the fire safety level of existing tunnel is low, possible approaches and solutions are presented according to the analysis of fire safety level. In order for these approaches to be effective, existing tunnel should be supplemented appropriately and extra equipment must be installed according to the solutions. Hopefully, by performing both improvement of existing utility tunnel that provide a fire/disaster proof and introducing new types of tunnel which influence utility management and maintenance, the recent disaster rate in Korea can be diminished up to a desirable rate in a near future.

  • PDF

Evaluation of Evacuation Safety in University Libraries Based on Pathfinder

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.237-246
    • /
    • 2024
  • In recent years, the frequent occurrence of fire accidents in university libraries has posed significant threats to the safety of students' lives and property, alongside negative social impacts. Accurately analyzing the factors affecting evacuation during library fires and proposing optimized measures for safe evacuation is thus crucial. This paper utilizes a specific university library as a case study, simulating fire evacuation scenarios using the Pathfinder software, to assess and validate evacuation strategies and propose relevant optimizations. Pathfinder, developed by Thunderhead Engineering in the United States, is an intuitive and straightforward personnel emergency evacuation assessment system, offering advanced visualization interfaces and 3D animation effects. This study aims to construct evacuation models and perform simulation analysis for the selected university library using Pathfinder. The library's structural layout, people flow characteristics, and the nature of fire and smoke spread are considered in the analysis. Additionally, evacuation scenarios involving different fire outbreak locations and the status of emergency exits are examined. The findings underscore the importance of effective evacuation in fire situations, highlighting how environmental conditions, individual characteristics, and behavioral patterns significantly influence evacuation efficiency. Through these investigations, the study enhances understanding and optimization of evacuation strategies in fire scenarios, thereby improving safety and efficiency. The research not only provides concrete and practical guidelines for building design, management, and emergency response planning in libraries but also offers valuable insights for the design and management of effective evacuation systems in buildings, crucial for ensuring occupant safety and minimizing loss of life in potential hazard situations