• 제목/요약/키워드: Fire Protection Door

검색결과 29건 처리시간 0.029초

방화문 내부 심재로 적용하기 위한 경량기포콘크리트의 물리적 성능 검토 (A Review of the Physical Performance of Lightweight Aerated Concrete for Use as an Interior Core Material in Fire Doors )

  • 홍상훈;김봉주;정의인;김해나;박준서
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2023
  • With the development of cities, the density of the population is continuously increasing as buildings become larger and more high-rise, but since the Haeundae residential complex fire in Busan in 2010, there has been a growing need to meet the fire protection performance of buildings as large-scale fires continue to occur every year. On the other hand, fire doors, which are one of the fire protection performance of buildings, have been judged unqualified in 82% of cases when fire doors constructed on the actual site were inspected after completion. The reason for this is that paper honeycomb and glasswool, which are used as core materials for fire doors, absorb moisture, reducing thermal insulation performance, and sagging due to increased weight, leading to performance degradation due to warping in empty spaces. To overcome these problems, research is underway to apply lightweight aerated concrete, an inorganic material, as a core material. Therefore, in order to select a blowing agent that produces stable bubbles prior to the production of lightweight bubble concrete for application as a fire door inner core, this study examined the physical performance according to the type of blowing agent and dilution concentration, and the following conclusions were drawn. Compared to vegetable bubbles and independent bubbles, synthetic bubbles have 3~8% higher thermal conductivity than independent bubbles, but 3~6% lower slurry density than vegetable bubbles, and 2~13% higher compressive strength, which is thought to be an improvement of synthetic bubbles.

  • PDF

피난 지연시간의 적용과 방화문 개방 정도에 따른 피난 안전성 확보에 관한 고찰 : 주거형태를 중심으로 (A Study on the Safety of Evacuation according to Evacuation Delay Time and Fire Door Openness: Based on Residence Types)

  • 서동길;김미선;구선환;송영주
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.156-165
    • /
    • 2020
  • 본 논문은 주거형태를 가지는 건축물의 성능위주설계 시 수행되는 피난 지연시간(인지 시간 + 개시 시간)의 적용과 세대 내 방화문의 개방 정도가 피난 안전성 평가에 어떠한 영향을 미치는지 파악하고 현실적 대안을 제시하기 위한 논문이다. 본 연구를 수행하기 위해 먼저 2018년 6월까지 시행되었던 광주광역시의 성능위주설계 대상 건축물 중 주거형태를 가지는 건축물(공동주택, 도시형생활주택 등)의 피난 안전성 평가에 대해 선행 조사를 하였다. 그런 다음 선행 조사된 건축물 중 일반적으로 많이 사용되고 있는 2가지 대표적인 Type에 대해 피난 지연시간은 W1, W2를 적용하고 방화문의 개방 정도는 전체개방, 1/4 개방, 누설 틈새를 각각 적용하여 시뮬레이션한 다음 피난 안전성 평가를 수행하였다. 피난 안전성 평가의 수행결과 방화문 개방 정도가 전체개방 및 1/4 개방 상태에서 사생활 침해 등을 고려하여 피난 지연시간 W2를 적용한 경우에는 피난 안전성을 모두 확보하기 어려운 것으로 나타났으며, 누설 틈새를 적용한 경우에만 피난 지연시간 W2를 적용해도 피난 안전성이 확보되는 것으로 나타났다. 따라서, 주거형태를 가지는 건축물이 성능위주설계 대상이 될 때 피난 안전성 평가 수행 시 CCTV 설치 등으로 사생활 침해 등의 우려가 있는 국내 현실을 반영하여 피난 지연시간은 W1보다는 W2의 적용을 검토하고 방화문의 차연성능 확보 및 성능위주 설계의 고도화를 위해 방화문의 개방 정도에 누설 틈새를 적용하는 방안도 함께 검토해 줄 것을 제안하고자 한다. 이를 통해 성능위주 설계 시 좀 더 현실화된 자료로 피난 안전성 평가를 수행함으로써 한 단계 더 발전된 성능위주설계가 될 것으로 기대된다.

방화문 내화성능 확보에 대한 제도적 문제점 및 해결방안 (Problems and Solutions for Securing Fire Resistance Performance in Fire Protection doors)

  • 김주성;김시원;조영덕;김재준
    • 한국건설관리학회논문집
    • /
    • 제21권2호
    • /
    • pp.22-29
    • /
    • 2020
  • 많은 내화 및 방화 등 화재관련 법규와 기준들 중 방화문은 화재 발생 시 화재 및 연기의 확산을 막아 인명의 피해를 최소화하는 역할을 하는 중요한 시설물이다. 이에 따라 해당 법규 및 관련 시행규칙 및 고시를 통해 소요되는 성능에 대한 기준을 지속적으로 상향시켰고 필히 해당 성능을 확보하도록 한다. 하지만 관련 법규와 제도의 맹점으로 인해 방화문 시험결과 합격품조차 방화성능에 리스크가 있는 것을 확인하였다. 이에 본 연구는 내화관련 성능의 기준을 분석하고, 단순 방화성능 외에 추가적으로 다른 법에서 요구하는 성능을 확인하여 기준을 정리하고, 요구하는 복합적인 성능을 명확히 규정하고자 하였다.

학교건물의 노후화에 따르는 개축 판정에 관한 모델의 정립 (School-Building Remodelling Model using Discriminant Analysis - A Case Study for Class Rooms in School Building -)

  • 민창기
    • 교육시설
    • /
    • 제4권4호
    • /
    • pp.29-41
    • /
    • 1997
  • The objective of this paper is to construct a model to be used in deciding whether to repair or rebuild school buildings is depending on their ages and other factors. The theme of this paper is the age is the main variable but other factors such as floor, innerwall, ceiling, door, inner window of the class room, outer window of the class room, inner window of the corridor, outer window of the corridor, middle window between the classroom and the corridor, light, heater, speaker, fire protection sensor, TV monitor, and telephone status would influence the final decisions. This paper employs an experimental case study method. Using the stepwise, statistical, classification method commonly used in discriminant analysis, it evaluates 12,766 rooms of 87 different high schools in Seoul. The result of this study indicates that some critical variables influencing the final decisions are the status of TV monitor, middle window between the classroom and the corridor, light, inner window of the corridor, fire protection sensor, innerwall, speaker utensil, outer window of the class room, and door of the class room. This paper also suggests a linear discriminant function will be used for this kind of studies. Finally the paper recommends policies with respect to the variables and discriminant functions evaluated.

  • PDF

조사연구-각국 방화문의 내화시험 방법 비교

  • 박승인
    • 방재기술
    • /
    • 통권18호
    • /
    • pp.28-35
    • /
    • 1995
  • To survive in the 21C every nations in the World squeeze their intelligence. To our country, having a marvelous growth career in viewpoint of the economy, making efforts to renovate. Behind the breath of the economy a lot of law, regulations, standards of industry, and specifications are exists and the in-dustry controlled by these. Regretably in spite of surprising growth of our economy in a short period still keeps them old rules as they have been applies on our industry without change. In the part of the rife resistance standards, espacially for the fire door, needs grad-up much for the recently version compared with the other countries's. The rapid reshape of the world urges us be revolutionized in the part of the software, ie. these unchanged rules.

  • PDF

국내 고층건물의 피난성능확보를 위한 급기가압방연(제연) 시스템의 제도개선연구 (A Legal Alternative for Effective Application of Pressurized Smoke Control System to Provide ′Smoke-free′ Access for Escape Shafts Used in High-Rise Building)

  • 박형주;김상욱
    • 한국화재소방학회논문지
    • /
    • 제15권4호
    • /
    • pp.49-56
    • /
    • 2001
  • 화재시 특별피난계단의 부속실의 연기침입을 방지하기 위해 적용하고 있는 급기가압방연시스템의 효능에 대한 논란이 증가하고 있는 바, 국내 고층 건축물의 특별피난계단에 설치운용중인 급기가압시스템의 설계시 핵심요소인 가압공간의 누설틈새, 계단실과 부속실 또는 부속실과 거실공간사이의 출입문을 통한 방연풍속과 출입문의 자동폐쇄를 보장하는 도어 개폐장치등에 대한 문제점을 조사연구하여 실질적인 효과를 보장할 수 있는 기준을 설정하고, 안전성확보를 보장하면서 경제성을 고려한 설계안을 세부적인 사례를 들어 구체적으로 제시하였다.

  • PDF

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

반발력 적용식에 대한 연구 (A Study on Application Formulas of The Reaction Force)

  • 정기신
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.91-95
    • /
    • 2011
  • 반발력을 계산하는 여러 가지 식이 있다. 이 식들이 어떻게 유도되고 어디에 사용되는지를 고찰하였다. 각 식들이 옥내소화전이나 옥외소화전의 노즐 같은 실제 소방설비에 적용될 때에는 무엇을 주의하여야하는지에 대하여 알아보고 적절한 사용방법을 제시하였다.

  • PDF

계층적분석기법을 통한 공동주택의 방화문 기능 개선에 관한 연구 (A Study on the Improvement of Fire Protection Door Performance in Apartment Houses through Analytic Hierarchy Process (AHP))

  • 하주익
    • 한국재난정보학회 논문집
    • /
    • 제15권4호
    • /
    • pp.540-547
    • /
    • 2019
  • 연구목적: 본 연구는 건설에 따른 하자보수 소송이 빈번히 발생하고 있는 공동주택 방화문 성능에 대한 문제점과 기능개선의 우선순위를 도출하는 것을 목적으로 한다. 연구방법: 연구를 위하여 방화문의 설계 및 시공 관련 전문가를 대상으로 설문조사를 시행하고 그 결과를 계층적분석기법(AHP)를 이용하여 분석하였다. 연구결과: 분석결과 2계층에서는 '방화구획 설치기준 강화' 28%, '설계기술 강화' 19.5%,'시공기술 강화' 19.3% 의 순이었으며, 3계층에서는 '바닥면적별 설치기준 강화' 11.8%, '내화구조 기준강화' 9.9%의 순으로 개선에 대한 우선순위로 분석되었다. 결론: 본 연구를 통해 화재시 거주자들의 생명과 직결되는 방화문의 안전성능에 대한 문제점을 인식하고 전문가들이 생각하는 기술적, 정책적 개선사항을 고려한 제도적 개선방안이 마련되어야 할 것이다.

팽창흑연을 사용한 복합재료의 난연 특성에 관한 연구 (A Study for the Fire Retardant-Characteristics of Expandable Graphite Composite Materials)

  • 전관옥;이동호
    • 한국안전학회지
    • /
    • 제32권3호
    • /
    • pp.28-33
    • /
    • 2017
  • In this study, the composite material of expandable graphite was made to the material development for improving such as a composite material of the sandwich panels or material properties of a fire door and was tested by the ISO 1182, ISO 5660-1(Cone calorimeter Method). For the test, the composite material of expandable graphite, what the expandable graphite ratio was increased by respectively 0g~30g, was classified A1,A2, A3, A4, and made to the test specimens. Through cone calorimeter test, peak heat release rate(HRR) and total heat release(THR), expanded thickness and expansion rate of each composite material of expandable graphite, and fire prone crack and mass loss rate after burning was measured. Thus, the effect of the addition of the expandable graphite and whether is suitable for reference as a fire retardant, was analyzed. Consequently the correlation of THR and fire retardant performance rate was confirmed.