• 제목/요약/키워드: Fire Protection Door

검색결과 29건 처리시간 0.02초

강철재도어에서 현장가공조립이 용이한 도어락상자틀 보강방법에 대한 연구 (A Study on the Reinforcement Method of the Door Lock Box Frame for Easy Field Processing Assembly in Steel Door)

  • 임보혁;이주원;조성권;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2023
  • In general, all buildings are equipped with various types of handles for opening and closing the door, and unlike wooden doors, steel doors such as fire doors are equipped with a box-shaped door lock box frame surrounding the outside of the door lock to protect the door lock, which is called a cylinder protection cover. These cylinder protection covers have various types and types of fastening structures, and the cylinder protection covers on the market are molded in factories and standardized according to the size and shape of the door lock, requiring various types of cylinder protection covers. Accordingly, a variable cylinder protection cover with a simple prefabricated structure that can fundamentally solve these problems can be used as one cylinder protection cover regardless of the type, shape, and size of the door lock.

  • PDF

부속실 급기가압 시 압력특성 변화에 관한 연구 (A Study on the Pressure Change during the Pressurization to the Elevator Lobby)

  • 김범규;박용환;김홍식
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.99-104
    • /
    • 2012
  • 본 연구에서는 공동주택 화재 시 피난시나리오 및 화재실 배연개구부 유무에 따른 부속실 급기가압 시스템의 성능 및 효용성을 평가하기 위해 각 실의 압력변화 특성을 실험적으로 측정하였다. 그 결과, 화재실문과 계단실문 개폐 시나리오 및 배연개구부의 유무에 따라 압력변화 특성이 크게 달라졌으며 최저설계차압으로 재안정화 되기 전에 부속실 과압 또는 부압 발생, 도어클로져 닫힘 기능 저하 등의 현상이 나타났다. 또한. 급기댐퍼의 설치위치보다는 화재실 배연개구부의 존재가 규정방연풍속 유지에 필수적인 것으로 나타났다.

스크린도어(PSD)의 개폐율에 따른 피난소요시간 분석에 관한 연구 (Study on the Evacuation Time Analysis by Platform Screen Door Opening Rate)

  • 김민재;민세홍
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.59-64
    • /
    • 2016
  • Platform Screen Door System (PSD)는 지하철 승객의 편의 및 안전을 위해 설치되기 시작하였고, 현재 전국 9개 운영기관이 관리하고 있는 824개 역사 중 전체의 71.8%에 해당하는 592개 역이 PSD를 운영 중에 있다. 본 연구에서는 전동차 정차 위치에 따른 PSD와 전동차 가동문 사이의 개폐율 변화를 분석하였고, 수도권 지하철을 운행 중인 기관에서 제공받은 재차인원 자료 분석 및 피난시뮬레이션을 통해 각 역사별 피난소요시간을 산정하였다. 연구결과 승객이 매우 혼잡하게 밀집되는 일부 고밀도 역사에서는 PSD 개폐율에 따라 매우 위험한 상황이 초래될 수 있음을 알 수 있었다. 특히 정위치에서 7 m 벗어난 곳에 정차할 경우 PSD의 고정 안전보호벽과 맞물려 열차 출입문 절반 이상이 폐쇄되는 것으로 분석되었다. 이러한 문제점을 개선하기 위해 기(旣) 설치된 PSD 고정안전보호벽을 모두 개폐 가능한 비상문으로 교체 및 개량하는 것을 제안한다.

방화문의 누설틈새 계산 및 연돌효과 분석 (The Leakage Crack Calculation of the Fire Door and the Stack Effect Analysis)

  • 김일영;권창희
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.46-53
    • /
    • 2013
  • 건축의 환경이 변하면 그에 따른 설계기준도 변하여야 한다. 방화문의 시험기준이 2005년 7월 27일 차연성 시험이 적용되면서 문틈이 기밀한 구조로 바뀌었다. 그러나 국가화재안전기준은 영국의 자료를 인용한 과거의 문틈규정을 적용함으로서 현실과 설계 규정의 차이가 오차나 안전율 이상으로 과도하다. 설계와 현실의 차이로 인하여 발생하는 결과 및 현상을 분석하고 개정되어야 할 국가화재안전기준의 누설틈새면적 계산법을 제시하고 연돌효과로 인한 방연풍속의 차이를 분석하였으며 생활패턴 및 피난패턴을 반영한 공동주택의 방연풍속 측정법에 대해 고찰하고 합리적인 측정법을 제시하였다.

FASTLite를 이용한 backdraft 사고의 해석 (An analysis of a backdraft using FASTLite)

  • 김진국
    • 방재기술
    • /
    • 통권22호
    • /
    • pp.9-16
    • /
    • 1997
  • This paper has two objectives. One is to introduce a software package, "FASTLite" for fire safety engineering calculation, the other to show the modeling result of a backdraft incident on the 62 WATTS street. A classic backdraft usually persists only seconds before exhausting their fuel supply but in this case the flame had persists for at least 6 and a half minutes. It is truly necessary to find out where the fuel came from to feed this flame for so long. The backdraft is successfully modelled by using FASTLite. To help understanding of this backdraft, the calculation with the door open is also carried out and compared to the backdraft.

  • PDF

진공가압식 목재방화문의 내화특성 연구 (A Study on Fire Resistance Characteristics of the Vacuum Pressurized Wood Fire Door)

  • 김인범;차정민;현성호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.351-353
    • /
    • 2010
  • 건축물에서 방화, 방음, 기밀, 단열 등의 용도로 사용되어지는 방화문은 외관의 단순함과 재질의 제한성 때문에 선택의 폭이 넓지 않았으나 최근에는 외관의 미려함을 고려하면서도 친환경성을 부여한 방화문들이 등장하고 있다. 하지만 방화문으로서 갖추고 있어야 하는 화재발생 시에 일정시간이내로 내화성을 부여해야 하는 측면에서는 어려움이 있다고 하겠는데 특히 목재방화문의 경우에는 경량화되면서도 내화성을 지닐 수 있는 방화문이 더더욱 요구되어지고 있기 때문에 목재방화문에 관한 내화특성을 실험을 통해 측정하였으며 화재안전성을 평가해 보았다.

  • PDF

A Study on Smoke Movement in Room Fires with Various Pool Fire Location

  • Jeong, Jin-Yong;Ryou, Hong-Sun
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1485-1496
    • /
    • 2002
  • In order to investigate the fire-induced smoke movement in a three-dimensional room with an open door, numerical and experimental study was performed. The center, wall, and corner fire plumes for various sized fires were studied experimentally in a rectangular pool fire using methanol as a fuel. The numerical results from a self-developed SMEP (Smoke Movement Estimating Program) field model were compared with experimental results obtained in this and from literature. Comparisons of SMEP and experimental results have shown reasonable agreement. As the fire strength became larger for the center fires, the air mass flow rate in the door, average hot layer temperature, flame angle and mean flame height were observed to increase but the doorway-neutral-planeheight and the steady-state time were observed to decrease. Also as the wall effect became larger in room fires, the hot layer temperature, mean flame height, doorway-neutral-planeheight and steady-state time were observed to increase. In the egress point of view considering the smoke filling time and the early spread of plume in the room space, the results of the center fire appeared to be more dangerous as compared with the wall and the corner fire. Thus it is necessary to consider the wall effect as an important factor in designing efficient fire protection systems.

화재 탈출 체험 VR 게임 개발과 효과 분석 (A Study on the Development of a VR Game to Experience the Fire Evacuation and its Effect Analysis)

  • 김경식;박용환
    • 한국게임학회 논문지
    • /
    • 제20권2호
    • /
    • pp.153-162
    • /
    • 2020
  • 본 연구에서는 건물 화재의 위급한 현장 속에서 침착하면서도 신속하게 탈출해야하는 상황을 가상 체험하는 VR 기능성 게임을 개발하였다. 사용자는 바이브(VIVE) 양손 컨트롤러를 이용하여 화재 건물 속에서 방화문과 계단, 복도을 통해 출구로 탈출해야한다. 화염이나 연기로 인하여 더 이상 진행하지 못하면 돌아서서 다른 통로로 진행할 수 있다. 호서대의 한 건물을 모델링 하였으며, 학생들에게 본 게임을 체험시키고 사용성과 효과성을 중심으로 설문 조사하여 그 반응 결과를 분석하였다.