• Title/Summary/Keyword: Fire Management

Search Result 1,695, Processing Time 0.026 seconds

A Study on the Policy Tasks for the Development of National Fire Service - Redesigning Institutional and Organizational Improvement for the Establishment of the National Fire Service Agency - (한국소방발전을 위한 정책과제 연구 - 소방청 신설에 대응하는 제도·조직개선 구상 -)

  • Choi, Byoung-Hahk;Kim, Hak-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.185-197
    • /
    • 2002
  • Today, the basic problem of functional safe management of Korean Disaster Control system was separately administrated 33 acts that are relating to safe management in 13 ministries. Because of the facts that the fire service is not provided practically, the control system and risk management for safe administration are not operated, the information can not be shared with each other, and the various laws have the lacks of linkage, the National Safe System was appeared unsteady. The roles and functions of fire service have started with restriction to operate structurally and institutionally, which operational structure of fire service is becoming weak. As a result, the federal and local fire organizations have not reached yet to the institutionalization and the local fire service agencies have bias with the task regarding the fire service because of the relation between organizational structure and the local fire agency. With the enforcement of the federal and local fire system, professionality and autonomy for making policy, and dealing with changes of fire service positively, the national fire service on the policy performance can be established. Promotion of research and development and education training to strengthen innovation in technology and competition in fire industry will contribute to the firmly establishment of control system to prevent from fire, flood, terror and national disaster. This article proposed that (a) the established law and administration, agency are required efforts to effectively operate fire service system; (b) the national fire service agency, national college of fire, national institute of science fire, and national fire service hospital should be early established to make firmly policy to operate effectively and practically. These kinds of innovational acts are known the best ways of operating solid policy of national fire service system.

  • PDF

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

A Study on the Fire Risk Assessment : Based on the Proposal of a Fire Risk Assessment Processor Considering the Reality in Korea (화재위험도 평가에 대한 연구 : 국내 현실을 고려한 화재위험도 평가 프로세서 제안을 중심으로)

  • Lee, Jong Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.57-64
    • /
    • 2021
  • Recently, advanced countries assessment the risk of fire to prevent large-scale damage to high-rise buildings, In addition, performance-Based design, which is a fire risk assessment, is being conducted in Korea to prevent massive damage to high-rise buildings. However, unlike advanced countries, fire risk assessment in Korea is subject to fire risk assessment only for objects subject to consent from fire-fighting facilities such as building permits, When building engineers and fire-fighting engineers assessment the risk of fire, It has always been discussed because the results vary depending on which part of the evaluation is focused between economic feasibility and safety. Therefore, in this study, we would like to propose a fire risk assessment process suitable for domestic conditions by comparing the process of performance-based design, which is a domestic fire risk assessment, and the process of Iso/TC 16732 which is an overseas fire risk assessment.

Fire and Rangeland's Management in India

  • Paulsamy, S.;Manian, S.;Kil, Bong-Seop
    • The Korean Journal of Ecology
    • /
    • v.28 no.1
    • /
    • pp.55-61
    • /
    • 2005
  • Fire, usually a detrimental factor makes changes in commonly structure and functions when it is practiced properly. In countries like Australia, South Africa, Japan and Texas in USA etc., fire is used as a tool to manage the natural ecosystems in productive condition on the basis of ecological approach. However, in developing countries like India there is effective measure to use and control fire in rangelands. This review provides knowledge on changes in sociological characters of plants, biomass profile, cycling of materials and strategy to use fire for the shaping of communities in different rangelands located in India and other countries. Further, the informations furnished in this article will be more useful for the forest managers, planners of rangelands and administrators in countries like India and tropical countries with similar bioclimatic conditions to prepare appropriate management plans where the fire is an integral factor.

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

The Influence of Emotional Labor at Seoul Management Operations Center on Job Performance : Focusing on the Mediating Effect of Social Support (서울종합방재센터 종합상황실 소방공무원의 감정노동이 조직몰입에 미치는 영향 - 사회적 지원의 매개효과를 중심으로 -)

  • Park, Chan Seok;Kim, Jin Keun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.13-25
    • /
    • 2015
  • In recent years, the surroundings of Fire have rapidly changed and citizens need for Fire have been demanding very high. Under these situations, in order for satisfaction to all these demands, Seoul Emergency Operations Center have made improvements as the core fire operational center in Korea. However, There have been so many problems happening in the middle of receiving calls from malice citizens of Seoul. The purpose of this study is to scrutinize current operations focused on fire fighters in Seoul Emergency Operations Center and to cope with how to overcome these problem by using AMOS 21 & SPSS Statistics 21. The result of this study presents that how we can find to be Seoul Emergency Operations Center running well. And This study is applied to seoul fire policies or helped to setting them up.

A Study on the Arson Fire Char-acteristics based on Computer Simulation (컴퓨터 시뮬레이션에 의한 방화화재 특성에 관한 연구)

  • Choi, Jin
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.239-253
    • /
    • 2007
  • With the development of the Korean economy, the number of arson fire has been radically increased and become a huge problem and issue in Korea Society for last several decades. This study is to establish the fire life safety strategy regarding the arson fire through performing the computer simulation based on fire scenarios with researching domestic fire statistics and cutting edge techniques and methods for fire characteristics and fire dynamic. In addition, to design the fire life safety strategy depending on the arson fire pattern, the flow and characteristics of fire flames and smoke is analyzed by the computer modeling.

  • PDF

The Study on the Factors Affecting the Effectiveness of Disaster Management in Governance - Focused Recognition of Fire Officials' - (재난관리 거버넌스의 효과성 영향요인 분석 - 소방공무원의 인식을 중심으로 -)

  • Chae, Jin;Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.79-90
    • /
    • 2009
  • Till now disaster management is limited to be performed usually by the government. However, government has its limits to carry out disaster management effectively. Thus, diverse organizations and groups such as related agencies, citizens, NGOs, companies, are required to be formed as a multi-organizational cooperation system that is governance of disaster management. This research deals with concepts of disaster management, governance. Therefore, this study presents that effective disaster management plans such as citizens' support and cooperation with related agencies, forming professionalism and active cooperation with disaster management between volunteering and volunteer fire department and well-organizing NGO network, by minutely understanding the concepts of disaster management, governance and others and also positively analyzing influence factors of efficiency of disaster management.

Categorizing Safety Management Elements for Fire Preparation and Assessemnt of Fire Hazard (화재에 대비한 지하공간의 안전관리 요소분류 및 화재위험성 평가방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.96-109
    • /
    • 2011
  • In this study, risk categorized five safety management elements(equipment and structure, evacuation, lifesaving and fire extinguishing, performance based fire safety plan, operations management) were classified in order to establish safety system of underground space. Using classified safety management elements, assessment of fire hazard was performed. After calculating the grade of evaluation categories, assessment of fire hazard was suggested. The three grades of evaluation categories are classified as to importance and four criteria of evaluation are classified as to check result based on subdivisions.