• Title/Summary/Keyword: Fire Inspection

Search Result 300, Processing Time 0.022 seconds

Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network (인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가)

  • Darkhanbat, Khaliunaa;Heo, Inwook;Choi, Seung-Ho;Kim, Jae-Hyun;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.111-120
    • /
    • 2021
  • When a fire occurs in a commercial building, the evacuation route is complicated and the direction of smoke and flame is similar to that of the egress route of occupants, resulting in many casualties. Performance-based evacuation design for buildings is essential to minimize human casualties. In order to apply the performance-based evacuation design to buildings, it requires a complex fire simulation for each building, demanding a large amount of time and manpower. In order to supplement this, it would be very useful to develop an Available Safe Egress Time (ASET) prediction model that can rationally derive the ASET without performing a fire simulation. In this study, the correlations between fire temperature with visibility and toxic gas concentration were investigated through a fire simulation on a commercial building, from which databases for the training of artificial neural networks (ANN) were created. Based on this, an ANN model that can predict the available safe egress time was developed. In order to examine whether the proposed ANN model can be applied to other commercial buildings, it was applied to another commercial building, and the proposed model was found to estimate the available safe egress time of the commercial building very accurately.

Fire Resistant Properties of the RC Columns Applying Various Splling Prevention Methods (폭렬방지공법 변화에 따른 RC 기둥부재의 내화특성)

  • Han, Cheon-Goo;Pei, Chang-Chun;Lee, Jong-Suk;Lee, Chan-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.119-126
    • /
    • 2009
  • This study investigated the fire resistance of RC columns applying Fiber addition method, Fire board attaching method, and Fire proof sparying method. The results were summarized as following. The test showed that increase of fiber content, as expected, decreased the fluidity of fresh concrete, but for the types of fiber, the specimens containing nylon(NY) was favorable. The incline of fiber content also affected on the air content of concrete, which the specimens adding polypropylene(PP) fiber was the lowest, followed by a less decrease in polyvinyl alchhol(PVA) and then NY respectively. For the compressive strength at 28days, it was over 50MPa and showed slight increasing tendency by rising fiber contents. After the fire test completed, control concrete exhibited the severe demage, while the specimens containing more than 0.05vol.% of PP and NY was able to protect from spalling. In the case of splay, the partly spalling occurred at the all finishing material, however the RC columns were protected from spalling. For the methods attached with boards, all RC columns were protected except the dry attaching method. The reduced weight ratio was favorable because it was below 8 % except for plain concrete.

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

Analysis of Dispersion Characteristics of Guided Waves in Rails (레일 초음파의 분산 특성 해석)

  • Kang, Bu-Byoung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1257-1264
    • /
    • 2011
  • Guided ultrasonic waves propagating over long distances within a short period provide a fast long-range inspection method. However, structures with arbitrary cross-sections, such as rails, have complicated dispersion characteristics that make analysis of the ultrasonic signal difficult. Therefore, an understanding of the characteristics of the propagating waves in rails is important for the creation of a reliable and practical inspection system using guided waves. In particular, it is necessary to investigate the dispersion characteristics of the guided waves. This paper introduces a method for the calculation of the dispersion curves of KS60 rails by adopting a SAFE method, and discusses the possibility of using guided waves as a technique for rail inspection.

The Development of Inspection Checklist for Risk Recognition to Prevent Accidents at Worksites (작업현장 사고예방을 위한 위험인지 점검체크리스트 개발)

  • Lim, Hyung-Duk;Kawshalya, Mailan Arachchige Don Rajitha;Kim, Sang-Hoon;Oh, Young-Chan;Lee, Ho-Yong;Nam, Ki-Hoon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.811-816
    • /
    • 2022
  • Even though continuous management and supervision of reinforcement of policies to safeguard accidents at workplace and work sites were implemented. Accident prevention activities such as inspection and diagnosis are urgently required to induce a preliminary investigation to identify the risk factors for each type of work, before the work task to eliminate risks at the worksites. Since safety inspections at work sites were generally conducted through visual inspections, the results of safety inspections may vary depending on the findings and proficiency of the safety officers. The results of those inspections may have loopholes to prevent potential accidents at work. Therefore, the purpose of this study was to develop a risk identification checklist that can effectively perform safety inspections to prevent accidents at work sites. This study initially analyzed the previously developed accident checklist to identify current complications and issues in safety checklists. Based on the findings of major industrial accidents over the past three years, the relationship between accident, workplace, and work type were analyzed refereeing the safety inspection standards. A risk recognition-checklist was developed to provide basic data on identifying risk factors, and inspection guidance at work sites. To prepare for potential accidents by identifying and taking countermeasures to mitigate the high risk and serious accidents at sites by the guidelines of the checklist. The developed inspection checklist has been practically used by experts at work sites to perform safety inspections, and it has been verified its suitability, and feasibility, to prevent or mitigate workplace accidents, including securing the safety and health of field workers. The role of the developed safety checklist has been considered effective at worksites.

Real-Time Image Processing System for PDP Pattern Inspection with Line Scan Camera (PDP 패턴검사를 위한 실시간 영상처리시스템 개발)

  • Cho Seog-Bin;Baek Gyeoung-Hun;Yi Un-Kun;Nam Ki-Gon;Baek Kwang-Ryul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.3 s.303
    • /
    • pp.17-24
    • /
    • 2005
  • Various defects are found in PDP manufacturing process. Detecting these defects early and reprocessing them is an important factor that reduces the cost of production. In this paper, the image processing system for the PDP pattern inspection is designed and implemented using the high performance and accuracy CCD line scan camera. For the preprocessing of the high speed line image data, the Image Processing Part (IPP) is designed and implemented using high performance DSP, FIFO and FPGA. Also, the Data Management and System Control Part (DMSCP) are implemented using ARM processor to control many IPP and cameras and to provide remote users with processed data. For evaluating implemented system, experiment environment which has an area camera for reviewing and moving shelf is made. Experimental results showed that proposed system was quite successful.

A Study on the Improvement of Daily Inspection for the Safety of University Laboratory - Based on Delphi surney - (대학 연구실 안전을 위한 일상점검 개선방안에 관한 연구 - 델파이 조사를 기반으로 -)

  • Choi, Youn-Woo;Lee, yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.1
    • /
    • pp.38-48
    • /
    • 2019
  • The purpose of this study is to present a more effective daily checklist than the formal routine check before the experiment to prevent accidents in the university laboratory. To do this, we reconstructed the current daily checklist and previous research data and conducted a second Delphi survey. As a result, there were four general safeties such as arranging the laboratory, three mechanical safeties such as abnormal condition of machine and tool tightening parts, three electric safeties such as prohibition of loading around the electric distribution panel, six chemical safeties such as handling and managing harmful factors, three items of fire safety such as fire extinguisher inspection, five cases of gas safety gas container inspection, one item of biological safety such as the state of hand sterilizer management and one other item, which were provided in the daily checklist as twenty six categories in total. According to the opinions of related experts, it is necessary to have an easy and simplified daily checklist for actual daily checkups.

Effects of Task Stress on the Job Satisfaction of Fire Protection Management Workers (소방시설관리업 종사자의 직무스트레스가 직무만족에 미치는 영향)

  • Lim, Kyoung-Yeon;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.130-139
    • /
    • 2019
  • This study identified the level of task stress experienced by fire protection system management workers and analyzed the effects of task stress on job satisfaction and proposed future response. First, task stress according to background cause showed differences in relation to age, position, monthly salary, total career, license, and task, but there was no difference in relation to academic background. Second, of the sub-parameters of stress, physical environment, task demand, organizational system, lack of reward, and workplace culture have negative effects on job satisfaction as stress increases, while interpersonal relation conflict and job insecurity do not have any effect. In the future, it will be necessary to investigate the empirical causes of work overload and to study organization-level stress relief measures.

A Study on the Thermal Characteristics of Wire Connection Part Depending on the Screw Torque (나사조임토크에 따른 전선접속부의 열적특성에 관한 연구)

  • Kim, Si-Kuk;Jee, Seung-Wook;Park, Sang-Min;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.82-88
    • /
    • 2012
  • To analyze the thermal characteristics of wire connection part that is connected to a screw-clamping terminal block depending on screw torque, the normal screw torque defined in KS C 2625 and the abnormal screw torque that can occur due to loosened screws resulting from defective work or aged deterioration were used as experimental variables. After the same load was applied to normal and abnormal screw torques, the thermal characteristics of the wire connector were measured and compared with a thermal imaging camera. The findings from this study will be used to detect heating due to defective screw torque at terminal block connections during electric safety inspection in the future and minimize the hazard of electric fire.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.