• Title/Summary/Keyword: Fire Hose

Search Result 42, Processing Time 0.028 seconds

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

A Study on the Wearing Comfort of Firefighter's Protective Clothing (한국 소방방수피복의 착용만족도 및 개선방안에 관한 조사연구)

  • Chung Jung-Sook;Lee Youn-Soon
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.12 s.142
    • /
    • pp.59-67
    • /
    • 1999
  • This study analyzed firefighter's actual wearing condition of turnout gear The results are as fellows: 1. When a firefighter is employed, Korea applies only the minimum of firefighters stature and weight but America applies both the minimum and the maximum. The choice of size is highly related with stature more than chest circumference. 2. The satisfaction degree of thermal barrier is very low, 3%. They used rubber gloves rather than heatproof gloves. This is more serious in small country like 'up', 'myun' than in cities. For laundering, they used sprinkling method with firefighting hose. Firefigthers hoped that their clothes could be classified tv the seasons and fire places. 3. frefighter had high unsatisfaction with the movement of hands and leges in the aspect of movement adjustability, air permeability, weight, body temperature regulation, and breathing in the hygenic aspect, fire resistance, thermal resistance property, water proof, chemical reactivity and electrical conductivity. Thev were also unsatisfied with water proof boots and gloves. They were generally satisfied with helmets but firefighters over 90kg of weight were rather unsatisfied. 4. The satisfaction degree for physical fitness was very low and the items with which they were not satisfied depend on physical features. 5. To develop turnout gear, they wanted changes in design, material and size. Reflection tape need to be replaced with high quality products and they wanted the use of velcro and zipper in fastening system.

  • PDF

Analysis of Work Postures of Fire Fighters for Prevention of Musculoskeletal Disorders (소방대원들의 근골격계질환 예방을 위한 작업 자세 분석)

  • Roh, Hyo-Lyun;Son, Sung-Min;Oh, Hyun-Soo;Chang, Seong-Rok;Kim, Yong-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.71-78
    • /
    • 2011
  • The aim of study was to reduce risk factors of musculoskeletal disorders, and prevent it according to evaluation and analysis of its symptoms survey, and work postures which doing much frequently. This study was conducted by 64 firefighters. It was surveyed physical burden levels, distribution of musculoskeletal symptoms, and analized work postures by using ergonomics tools, such as Rapid Entire Body Assesment(REBA), Rapid Upper Lim Assessment(RULA), NIOSH Lifting Equation(NLE). Physical burden levels, and distribution of musculoskeletal symptoms were surveyed according to frequency analysis, and the analysis of above tools were presented figures and scores. The all the results of REBA were that risk level was "High", action level was "Need soon" and the results of RULA were "The results are required detailed survey and immediate improvement" at Require rescue person handling, fire hose, hybraulic rescue equipment, universal axe work postures. The occurrence possibility of musculoskeletal disorders of fire fighters is quite high due to instability postures, excessive physical work and so on. Thus, making various efforts to prevent disorders, and improving working environment is necessary continuously.

Evaluation on th e Wear Fit and Activity of Emergency Escape Breathing Devices for Ship Accidents (선박사고용 호흡구난장비의 착용성 및 활동성 평가 연구)

  • Noh, Jae-Hyeon;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.79-84
    • /
    • 2019
  • The use of emergency escape breathing devices (EEBD) is strongly required to protect against toxic gas or flooding caused by ship fires or accidents. Recently developed domestic EEBD products only satisfy the basic performance requirements, but no wear fit and activity performance evaluation has been done for real usage. In this study, the global level test requirements for wear comfort and activity of EEBDs were developed and the open and closed type of domestic EEBD products were evaluated. Poor visibility, longer wear time, breathing resistance, and hose obstruction in an open type and canister obstruction, weight unbalance, and an invisible black breathing bag in the closed type EEBD were estimated to be the main problems that need to be improved.

A Proposal for the Future of Summer in the Dosshouse (쪽방촌의 여름철 더위해결을 위한 방안 제시)

  • You, Nam Gyu;Kim, Min Sung;Kim, Bong Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.102-103
    • /
    • 2019
  • There are about 3,500 people living in the Seoul Dosshouse, including Namdaemun, Dongdaemun, Donui-dong, Changshin-dong, and Yeongdeungpo. The daytime temperature in the Dosshouse is 43 degrees and the indoor temperature is 35 degrees, which is also higher than the surrouding area. Most of them live in one-person the poor strata, where they have been fighting the heat and the summer. The old building is closely located and a 1.5-pyeong room without windows is a hot environment. Water, air-conditioning is difficult or impossible for people who are economically inferior and cannot solve their own solutions. The solution that can be provided by the country is to heat up once or twice a day by fire hose or shelter. However, there are many patients with discomfort, the distance is far, and the effect is insignificant. Therefore, through this experiment by using discarded banner, I would like to suggest a way to solve the summere heat of the Dosshouse.

  • PDF

An Analysis on Keywords in the Journal of Korean Safety Management Science from 2018 to 2021 (2018년부터 2021년까지 대한안전경영과학회지의 주제어에 관한 분석)

  • Byoung-Hak Yang
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • This study tried to analyze the keywords of the papers published in the Korea Safety Management Science by using the social network analysis. In order to extract the keywords, information on journal articles published from 2018 to 2021 was extracted from the SCIENCE ON. Among the keywords extracted from a total of 129 papers, the keywords with similar meanings were standardized. The keywords used in the same paper were visualized by connecting them through a network. Four centrality indicators of the social network analysis were used to analyze the effect of the keyword. Safety, Safety management, Apartment, Fire hose, SMEs, Virtual reality, Machine learning, Waterproof time, R&D capability, and Job crafting were selected as the keywords analyzed with high influence in the four centrality indicators.

Constructing a Database Structure for the Domestic LP Gas and Natural Gas Accidents and its Analysis (국내 LP 및 천연가스사고 Database 구축 및 분석에 관한 연구)

  • Ko, Jae-Sun;Park, Sun-Young;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.56-63
    • /
    • 2008
  • We have garnered 3,593 data of gas [Natural Gas (NG) and Liquefied Petroleum Gas (LPG)] accidents reported for 16 years from 1991, and then analyzed the accidents according to their types and causes based on the classified database. According to the results the gas leak has been the most common accident followed by the explosion and then fire accidents. The most frequent accident-occurring locations for fire, explosion and leak are recognized around the valve, hose and pipeline, respectively. In addition, we have applied the Poisson analysis to predict the most-likely probabilities of fire, explosion and release in the upcoming 5 years. From this research we have assured the successive database updating will highly improve the anticipating-probability accuracy and thus it will play a key role as a significant safety-securing guideline against the gas disasters.

  • PDF

Changes in The Amount of Air Respirator Consumed by Field Fire-fighting Activities (현장 소방활동에 따른 공기호흡기 소모량의 변화)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.93-98
    • /
    • 2019
  • The purpose of this study was to identify and analyze the rate of change of air respirator consumption based on field fire fighting activities, The results of the experiment are as follows. The mean air consumption of the Five subjects was $15.56{\ell}/min$ when standing still, $32.43{\ell}/min$ when walking with normal pace, $43.07{\ell}/min$ when the fire hoses was expanded and arranged, $55.28{\ell}/min$ when climbing stairs, The situation of running up the stairs and hitting the hammer continuously increases to $127.14{\ell}/min$, which means that the consumption of air increases according to the energy consumption. Despite being the oldest, Experimental subject A was $13.23{\ell}/min$ when standing still, $29.33{\ell}/min$ when walking normally, and $41.08{\ell}/min$ when the fire hose was deployed and arranged. This is a result of familiarity with deep and slow breathing methods. The average respiratory use rate of subjects D was $63.58{\ell}/min$. The reason for this is that obesity seems to increase the air consumption, and it is considered that the physical strength is exhausted by the action of the hammer, which has a greater influence on the increase of air consumption. The subject E had significantly lower air respiratory use rate of $49.90{\ell}/min$. The reason for this is that the age of E is the youngest among the subjects, and it is presumed that it possesses strong physical strength.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.

Proton Temperature Anisotropy vs Parallel Beta in the Solar Wind

  • Yoon, Peter H.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.92.2-92.2
    • /
    • 2011
  • In view of the planned NASA's and ESA's Solar Probe Plus and Solar Orbiter missions, respectively, to probe the inner heliosphere and the Sun's corona, it is timely to investigate outstanding problems associated with the solar wind. Among them is the temperature anisotropy problem. As the solar wind expands into the interplanetary space, the density and magnetic field decreases radially, thus leading to temperature anisotropy ($T_{\parallel}{\gg}T_{\perp}$). However, the measured temperature anisotropy can at times be characterized by $T_{\perp}$ > $T_{\parallel}$, while at other times the measured $T_{\parallel}/T_{\perp}$ is much milder than predicted by adiabatic theory. Physical reasons remain poorly understood. This notwithstanding, it is known from plasma physics that for $T_{\perp}$ > $T_{\parallel}$ electromagnetic ion-cyclotron (EMIC) and mirror instabilities are excited, while for $T_{\parallel}$ > $T_{\perp}$, fire-hose instability is excited. By constructing the threshold conditions for various instabilities, one may construct a closure relation that may be useful for modeling the solar wind. In the present paper we discuss theoretical construction of the anisotropy-beta relation by means of quasi-linear theories of these instabilities. The present work complements previous efforts on the basis of linear theory, hybrid simulations, and empirical fits of observations.

  • PDF